STUDER INNOTEC SI
Sinewave inverter
SI SERIES
User's and Installer's Handbook
STUDER INNOTEC
Rue des Casernes 57
CH-1950 Sion
Tel : ++41 (0)27 205 60 80
Fax: ++41 (0)27 205 60 88
info@studer-innotec.com
www.studer-innotec.com
User manual SI V3.0 E
ページ2に含まれる内容の要旨
STUDER INNOTEC SI Summary INTRODUCTION ................................................................................................................................ 3 NOTE..................................................................................................................................................... 3 APPLICATIONS AND PERFORMANCE ......
ページ3に含まれる内容の要旨
STUDER INNOTEC SI As for the usage of batteries, follow the Introduction manufacturer’s instructions. The SI sinewave inverters have been designed Important : to meet industrial and domestic needs. They After disconnecting the battery, the output satisfy the highest demands of comfort, safety tension (230V) may still remain for 30 and reliability. seconds
ページ4に含まれる内容の要旨
STUDER INNOTEC SI Check the tension and polarity of the battery ! Assembly The tension of the battery should coincide with that mentioned in the technical characteristics of Location the inverter. Battery connection : The place where the This connection should done be very inverter is to be carefully observing the polarity in order not mounted should t
ページ5に含まれる内容の要旨
STUDER INNOTEC SI Adjustments These values correspond to a no load situation (Not automatic with Twinpower version) and they are automatically adjusted according to Standby Level (1) the current of the battery. The activation of the inverter, when working in The internal temperature and the maximum automatic mode, is dictated by the detection of a power
ページ6に含まれる内容の要旨
STUDER INNOTEC SI Maintenance Options: The SI inverters do not need any special maintenance. The casing may be cleaned with a Alarm contact damp cloth (not wet). A contact with no potential (0,5A - 60V) is In the case of malfunction, the inverter should available (12). It warns the user (alarm or control be sent to the salesperson for control. system) w
ページ7に含まれる内容の要旨
STUDER INNOTEC SI Description and wiring diagram User manual SI V3.0 E 7
ページ8に含まれる内容の要旨
STUDER INNOTEC SI Wiring diagram for SI 600 - 800 S (Solar charge regulator) User manual SI V3.0 E
ページ9に含まれる内容の要旨
STUDER INNOTEC SI Option SI performance 3-phased Connecting Three SI inverters can be connected together to 1) Check that the inverters are in OFF position. build a 3-phased grid. They have to be equipped with the PE option. 2) First link together the neutral of all 3 devices by taking care that this connecting point be not Working further than 1
ページ10に含まれる内容の要旨
STUDER INNOTEC SI Technical data 612 812 1212 1624 2324 3324 3548 Model SI 624 824 1224 2348 648 1248 Input voltage (Unom) [V] 12/24/48 12/24 12/24/48 24 24V/48 24 48 Nominal power [W] 600 800 1200 1600 2300 3300 3500 « Standby » current [mA] 25/21/10 25/21 25/21/12 21 25/17 25 30 Power « ON » no load [W] 2.6 2.8 4.8 5.8 9 13 17 Power « ON » no load [W] --