16/32 Channel 1U Rack Mount
CCTV Power Supply
Manual
PH-A3224-GUQ Shown
16-Channel 32-Channel
PTC
PH-A1612-PUQ PH-A3224-PUQ
Glass Fuse
PH-A1612-GUQ PH-A3224-GUQ
Industrial design Easy cable management
12 Amp at 24VAC Dual-color LED status indicators
For rack mounting, wall
3 Amps per channel
mounting, and stacking
Field-selectable 24/28 VAC
Note: Model number that end with “Q” or that have a round green “Q” stic
ページ2に含まれる内容の要旨
ENFORCER RACKMOUNT POWER SUPPLY Table of Contents: 2 Introduction ......................................................... Sample Application .............................................7 Features..............................................................2 Overview .............................................................7 2 Installation Notes ................................................ Troubleshooting ..............................................
ページ3に含まれる内容の要旨
ENFORCER RACKMOUNT POWER SUPPLY Parts List: Rack mount power supply ........................................................................................................... 1x Cable management brackets ...................................................................................................... 2x Cable management hooks ........................................................................................................... 2x M3x6 Cable bracket screws ..............
ページ4に含まれる内容の要旨
ENFORCER RACKMOUNT POWER SUPPLY A2. Wall mounting (For 32-channel, see A4) Figure 1 Middle mounting point Bracket facing down 1. Remove the mounting screws from the middle mounting points as shown in Figure 1. 2. Screw the left and right mounting brackets on, Mounting bracket facing downward as shown in Figure 1. 3. Make sure no ventilation holes are blocked when the unit is in place. 4. Use screws or bolts (not included) to mount the unit in the desired location. Note: Ma
ページ5に含まれる内容の要旨
ENFORCER RACKMOUNT POWER SUPPLY B. Wiring 1. Unplug terminal blocks from their sockets for easy installation. 2. Connect equipment power input cables to the screw terminals side by side in N/P pairs. 3. Screw the terminals closed. Once done, reinsert the terminal block back into its slot. 4. Select channel voltage for each terminal block with the switches on the back of the unit. 5. For each group of channels, select either 24VAC or 28VAC. Switch unused channels to OFF. Tech T
ページ6に含まれる内容の要旨
ENFORCER RACKMOUNT POWER SUPPLY E1. Locking Tab, front position Figure 6 1. Install the front panel lock tab using the screw from the power Front panel supply front mounting point as Mounting bracket shown in Figure 6 to the right. 3 3 Front panel lock tab 1 2 2. To open: Loosen the screw and slide the lock tab toward the right Rack mount screw to let the front panel open. 3. To close: Slide the lock tab toward the left over the front panel and tighten the screw. Note
ページ7に含まれる内容の要旨
ENFORCER RACKMOUNT POWER SUPPLY Sample Application: Figure 9 DC Cameras, Accessories, etc. Rack Mount Power Supply Use ENFORCER Voltage Converters to supply your DC ST-LA110-TTQ ENFORCER Voltage Convertor equipment Overview: A: Front mounting point Figure 10 Mounting brackets Power supply front panel B: Center mounting point Rubber foot & mounting point Channel indicator LEDs Figure 11 Power supply rear panel Main fuse socket Cable management hook Ter
ページ8に含まれる内容の要旨
ENFORCER RACKMOUNT POWER SUPPLY Troubleshooting: Power does not turn on Check front panel LEDs and rear main fuse. Ensure the power cord is firmly in its socket. Power cycles on and off The unit may be overheating. Check for heat sources nearby and ensure ventilation holes are free from obstruction. Voltage drop is large Use 18 gauge or thicker wire. The camera case is hot Check that the correct power is being supplied. Also Available: Rack Mount Active 12VDC Tes