Powerware 9390 UPS
100–160 kVA
Installation and Operation Manual
ページ2に含まれる内容の要旨
IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions that you should follow during installation and maintenance of the UPS and batteries. Please read all instructions before operating the equipment and save this manual for future reference. Consignes de sécurité CONSIGNES DE SÉCURITÉ IMPORTANTES CONSERVER CES INSTRUCTIONS CE MANUEL CONTIENT DES CONSIGNES DE SÉCURITÉ IMPORTANTES ClassAEMCStatements FCC Part 15 NOTE Thisequipmenthasbeentestedandfoundtoc
ページ3に含まれる内容の要旨
Table of Contents 1Introduction............................................................ 1-1 1.1 Basic System Configurations................................................. 1-2 1.2 Using This Manual ......................................................... 1-3 1.3 Conventions Used in This Manual ............................................ 1-4 1.4 Safety Warnings........................................................... 1-5 1.5 For More Information...........................................
ページ4に含まれる内容の要旨
TableofContents 4 Batteries ............................................................... 4-1 4.1 Important Safety Instructions................................................ 4-1 4.2 Installing Batteries ......................................................... 4-2 4.3 Recycling the Used Battery or UPS ........................................... 4-2 5 Installing a Remote Emergency Power-off Switch .......................... 5-1 6 Installing Options and Accessories.............................
ページ5に含まれる内容の要旨
TableofContents 8 Features, Options, and Accessories ....................................... 8-1 8.1 UPS Standard Features ..................................................... 8-1 8.1.1 Control Panel ......................................................... 8-1 8.1.2 Customer Interface..................................................... 8-1 8.1.2.1 Building Alarm Monitoring .......................................... 8-1 8.1.2.2 Alarm Contact ....................................................
ページ6に含まれる内容の要旨
TableofContents 9.3 System Controls Screen .................................................... 9-45 9.4 Load Off Screen........................................................... 9-47 9.5 Reading the Status Indicators................................................ 9-48 10 UPS Operating Instructions .............................................. 10-1 10.1 Single Module Operation ................................................... 10-1 10.1.1 Starting the UPS in Normal Mode .....................
ページ7に含まれる内容の要旨
TableofContents 13 Communication......................................................... 13-1 13.1 X-Slot Cards .............................................................. 13-1 13.2 LanSafe Power Management Software ........................................ 13-2 13.3 Remote Notification ....................................................... 13-2 13.4 Terminal Mode ........................................................... 13-3 13.4.1 Display UPS Control Panel ...............................
ページ8に含まれる内容の要旨
TableofContents This page intentionally left blank. ® vi EATON Powerware 9390 UPS (100–160 kVA) Installation and Operation Manual S 164201604 Rev B powerware.com
ページ9に含まれる内容の要旨
Table of Contents Figure 1-1. Powerware 9390 UPS (100–160 kVA) Cabinet................................... 1-1 Figure 2-1. Powerware 9390 UPS (100–160 kVA) Cabinet as Shipped on Pallet................. 2-3 Figure 3-1. Removing Front Shipping Bracket on the Powerware 9390 UPS.................... 3-3 Figure 3-2. Removing Rear Shipping Bracket on the Powerware 9390 UPS .................... 3-4 Figure 5-1. REPO Switch............................................................... 5-1 Figure 6-1. Powe
ページ10に含まれる内容の要旨
TableofContents Figure 9-24. Maximum Current Log Setup Screen 1 ....................................... 9-21 Figure 9-25. Maximum Current Log Setup Screen 2 ....................................... 9-22 Figure 9-26. Time Interval Monitored Setup Screen ....................................... 9-23 Figure 9-27. Time Interval Monitored Setup Save Screen ................................... 9-24 Figure 9-28. Maximum % of Full Load Setup Screen ....................................... 9-25 Figure 9-29.
ページ11に含まれる内容の要旨
Chapter 1 Introduction ® The Powerware 9390 uninterruptible power supply (UPS) is a true online, continuous-duty, transformerless, double-conversion, solid-state, three-phase system, providing conditioned and uninterruptible AC power to protect the customer’s load from all nine power failures. The Powerware 9390 UPS is available as a single module or a multiple module parallel system (see paragraph 1.1). The Powerware online power protection system is used to prevent loss of valuable electronic
ページ12に含まれる内容の要旨
Introduction 1.1 Basic System Configurations The following basic UPS system configurations are possible: Single module UPS and one to four battery cabinets Single module UPS with UPS Sidecar (maintenance bypass or 1+1 tie configuration) and one to four battery cabinets Single module UPS, one to four battery cabinets, and an optional Integrated Distribution Cabinet (IDC) Single module UPS, one to four battery cabinets, and an optional Integrated Accessory Cabinet (IAC) (maintenance bypass
ページ13に含まれる内容の要旨
Introduction 1.2 Using This Manual This manual describes how to install and operate the Powerware 9390 UPS (100–160 kVA) cabinet. Read and understand the procedures described in this manual to ensure trouble-free installation and operation. In particular, be thoroughly familiar with the REPO procedure (see page 10-7). The information in this manual is divided into the sections and chapters listed. The system, options, and accessories being installed dictate which parts of this manual should be r
ページ14に含まれる内容の要旨
Introduction Chapter 14, “Maintaining the UPS System” – contains maintenance instructions for the UPS system. Chapter 15, “Product Specifications” – provides detailed specifications for the UPS system. Appendix A, “Installation Information” – contains important information on wiring requirements and recommendations, and important diagrams of the cabinets’ mechanical details and electrical access. Warranty – provides the Powerware warranty for this product. Read through each procedure bef
ページ15に含まれる内容の要旨
Introduction 1.4 Safety Warnings IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries. Please read all instructions before operating the equipment and save this manual for future reference. The UPS cabinet is designed for industrial or computer room applications, and contains safety shields behind the doors. However, the UPS system is a sophisticated power system and
ページ16に含まれる内容の要旨
Introduction 1.5 For More Information Refer to the Powerware 9390 Integrated Battery Cabinet (Models IBC-S and IBC-L) Installation Manual (164201536) for the following additional information: Integrated Battery Cabinet (IBC) installation instructions, including site preparation, planning for installation, wiring, and safety information. Detailed illustrations of the cabinet, including dimension and connection point drawings. Refer to the Powerware 9390 Integrated Distribution Cabinet (160 kV
ページ17に含まれる内容の要旨
Section I Installation ® 1-1 EATON Powerware 9390 UPS (100–160 kVA) Installation and Operation Manual S 164201604 Rev B powerware.com
ページ18に含まれる内容の要旨
This page intentionally left blank. ® 1-2 EATON Powerware 9390 UPS (100–160 kVA) Installation and Operation Manual S 164201604 Rev B powerware.com
ページ19に含まれる内容の要旨
Chapter 2 UPS Installation Plan and Unpacking Use the following basic sequence of steps to install the UPS: 1. Create an installation plan for the UPS system (Chapter 2). 2. Prepare your site for the UPS system (Chapter 2). 3. Inspect and unpack the UPS cabinet (Chapter 2). 4. Unload and install the UPS cabinet, and wire the system (Chapter 3). 5. Install features, accessories, or options, as applicable (Chapters 5 and 6). 6. Complete the Installation Checklist (Chapter 3). 7. Have authorized se
ページ20に含まれる内容の要旨
UPSInstallationPlanandUnpacking 2.2.1 Environmental Considerations The life of the UPS system is adversely affected if the installation does not meet the following guidelines: The system must be installed on a level floorsuitableforcomputerorelectronic equipment. The system must be installed in a temperature and humidity controlled indoor area free of conductive contaminants. Failure to follow guidelines may void your warranty. 2.2.2 Preparing for Wiring the UPS System NOTE Ifinstalling,aspa