ページ1に含まれる内容の要旨
Installation and
Pulsar EX
user manual
700 / 1000 / 1500
e-mail: info@direktronik.se
tel: 08-52 400 700 fax: 08-520 18121
51031604EN/AA - Page 1
ページ2に含まれる内容の要旨
Introduction Thank you for selecting an MGE UPS SYSTEMS product to protect your electrical equipment. The Pulsar EX range has been designed with the utmost care. We recommend that you take the time to read this manual to take full advantage of the many features of your UPS. MGE UPS SYSTEMS pays great attention to the environmental impact of its products. Measures that have made Pulsar EX a reference in environmental protection include: w the eco-design approach used in product development; w rec
ページ3に含まれる内容の要旨
Safety Safety rules Safety of persons A UPS has its own internal power source (the battery). Consequently, the power outlets may be energised even if the UPS is disconnected from the AC-power source. Dangerous voltage levels are present within the UPS. It should be opened exclusively by qualified service personnel. The UPS must be properly earthed. Measurements are required to ensure that the total leakage current of the UPS and the protected equipment does not exceed 3.5 mA. The battery supplie
ページ4に含まれる内容の要旨
Foreword Using this document Information may be found primarily by consulting: w the contents, w the index. Pictograms Important instructions that must always be followed. Information, advice, help. Visual indication. Action. Audio indication. In the illustrations on the following pages, the symbols below are used: LED off. LED on. LED flashing. Page 4 - 51031604EN/AA
ページ5に含まれる内容の要旨
Contents 1. Presentation 1.1 Pulsar EX range .......................................................................................................................... 7 Tower model.................................................................................................................................... 7 Rack model ..................................................................................................................................... 7 1.2 Back ...........................
ページ6に含まれる内容の要旨
Contents 3.4 Personalisation (optional) ........................................................................................................... 19 Function ........................................................................................................................................ 19 "ON / OFF conditions" tab............................................................................................................. 19 "Battery" tab ................................................
ページ7に含まれる内容の要旨
1. Presentation 1.1 Pulsar EX range Tower model Dimensions in mm (H x W x D) EX 700 / EX 1000 235.5 x 145 x 400 EX 1500 235.5 x 145 x 505 Weight in kg EX 700 10 EX 1000 12 EX 1500 15 Rack model Dimensions in mm (H x W x D) EX 700 Rack 88 (2U) x 482.6 x 430 EX 1000 Rack 88 (2U) x 482.6 x 430 EX 1500 Rack 88 (2U) x 482.6 x 493 Weight in kg EX 700 Rack 14 EX 1000 Rack 16 EX 1500 Rack 20 51031604EN/AA - Page 7 EX1000 Rack
ページ8に含まれる内容の要旨
1. Presentation 1.2 Back Tower model Pulsar EX 700 / Pulsar EX 1000 1 slot for communications-card option. 1 2 USB RS232 2 RS232 communications port. 3 3 USB communications port. 4 4 four outlets for direct connection of protected equipment. 5 connector for automatic detection of an 5 additional battery module. 6 1 7 6 input circuit breaker. 2 8 7 socket for connection to AC-power 9 source. 10 11 8 connector for an additional battery module. Pulsar EX 1500 9 pushbutton to test phase/neutral 1 in
ページ9に含まれる内容の要旨
1. Presentation Rack model Pulsar EX 700 Rack / Pulsar EX 1000 Rack / Pulsar EX 1500 Rack 3 7 1 4 11 USB 1 2 RS232 2 6 10 9 5 8 slot for communications-card option. 7 socket for connection to AC-power source. 1 2 RS232 communications port. 8 connector for an additional battery module. 3 USB communications port. 9 pushbutton to test phase/neutral inversion of AC-power source. 4 four outlets for direct connection of protected equipment. 10 LED indicating phase/neutral inversion of AC-power source.
ページ10に含まれる内容の要旨
1. Presentation 1.3 Control panel Alarms % battery ␣␣␣␣␣ % load remaining % 12 UPS overload. 100% 100% 100% 13 electronics fault. 80% 80% 80% battery fault. 50% 50% 50% 14 20% 15 20% 20% % 16 hold down to display percent load: - lamp test or buzzer OFF. test - forced transfer to bypass and back 17 by pressing button 3 times in less than 5 seconds. 1 18 status of programmable outlet 1: Supplied with power 2 19 status of programmable outlet 2: Status change in progress. operati
ページ11に含まれる内容の要旨
2. Installation 2.1 Unpacking and checks Tower model 24 26 25 29 27 28 two cords for connection of the protected equipment. 24 RS 232 communications cable. 25 USB communications cable. 26 "UPS Driver" diskette for UPS personalisation. 27 "Solution Pac" CD ROM. 28 documentation. 29 51031604EN/AA - Page 11
ページ12に含まれる内容の要旨
2. Installation Rack model 24 24 25 26 27 28 29 30 ␣ 24 two cords for connection of the protected equipment. ␣ 25 RS 232 communications cable. ␣ 26 USB communications cable. ␣ 27 "UPS Driver" diskette for UPS personalisation. ␣ 28 "Solution Pac" CD ROM. ␣ 29 documentation. ␣ 30 telescopic rails for mounting in 19" bay with mounting hardware. Page 12 - 51031604EN/AA EX1000 Rack
ページ13に含まれる内容の要旨
2. Installation 2.2 Installation of the rack version Rack mounting diagram with rails. 1 3 3 3 4 3 2 The rails and the necessary mounting hardware are supplied by MGE UPS SYSTEMS. 51031604EN/AA - Page 13 EX1000 Rack
ページ14に含まれる内容の要旨
2. Installation 2.3 Connection to the RS 232 or USB communications port (optional) 1 - Connect the RS 232 25 or USB 26 communications cable to the serial port or the USB port on the computer. 25 2 - Connect the other end of the RS232 USB communications cable 25 or 26 to the RS 26 2 3 232 2 or USB 3 communications port on the UPS. The UPS can now communicate with all MGE UPS SYSTEMS supervision, set-up or safety software. 3 2 The RS 232 and USB communications ports cannot operate s
ページ15に含まれる内容の要旨
2. Installation 2.4 Installation of the communications-card option Tower model 1 Slot for the communications-card It is not necessary to shut down the UPS to option. install the communications card: USB U-Talk 1 - Remove the slot 1 cover secured by two screws. 2 - Insert the card in the slot. 3 - Secure the card with the two screws. 1 2 Rack model 1 Slot for the communications- card option. USB 1 2 RS232 51031604EN/AA - Page 15
ページ16に含まれる内容の要旨
s e r s s 2. Installation 2.5 Connections Check that the indications on the rating plate on the back of the UPS correspond to your AC-power system and to the actual electrical consumption of all the equipment to be connected to the UPS. Tower model 1 - Remove the power cord supplying the equipment to be protected. Check cord characteristics (> 250 V, 10 A, see the 4 technical sheet). 7 2 - Connect the cord to the AC-power socket ␣ ␣ 7 , then to the AC-power wall outlet. ? 3 - Connect the protec
ページ17に含まれる内容の要旨
3. Operation 3.1 Start-up The protected equipment connected to the UPS can be energised, whether AC input power is available or not. Press the ON / OFF button 23 . The buzzer beeps and all the LEDs go ON. The buzzer beeps twice, then: - If AC input power is available, LED 21 goes ON, indicating operation in ON-LINE mode. - If AC input power is not available and the UPS is configured for 21 automatic restart mode, the buzzer beeps three times and LED 22 goes ON, signalling operation on batte
ページ18に含まれる内容の要旨
3. Operation 3.3 Operation on battery power (following failure of AC input power) Transfer to battery power The AC-power source is outside tolerances, LED 23 is ON, the buzzer 1 beeps three times. 2 by-pass The equipment connected to the UPS is supplied by the battery. 22 Threshold for the low-battery warning The low-battery warning threshold can be set by the user, with the "UPS 1 Driver" software (see section 3.4). 2 LED 22 flashes. by-pass The buzzer beeps every three seconds. There is ve
ページ19に含まれる内容の要旨
3. Operation 3.4 Personalisation (optional) Function Personalisation parameters can be set and modified using the "UPS Driver" software installed on a computer that is connected to the UPS (see section 2.3 Connection to the RS 232 (or USB) communications port). Check that the RS 232 25 or USB 26 cable is properly connected. "UPS Driver" installation: 1 - Insert the "UPS Driver" diskette in the drive of a PC running Windows. 2 - Select the disk drive (A:\). 3 - Double-click "upsdriv.exe". Onc
ページ20に含まれる内容の要旨
3. Operation "Output" tab Personalisable function Default setting Options Rated UPS voltage 230 V 200 V - 208 V - 220 V - 240 V Rated UPS frequency F = 50 Hz 60 Hz UPS tolerance for AC-power F ± 5% F ± 1% to ± 10%, in 1% steps source frequency Overload alarm threshold 110% 0 to 110%, in 10% steps UPS restart following short-circuit Disabled Enabled (click to add check) "Bypass" tab Personalisable function Default setting Options Transfer to bypass if overload Enabled Disabled (click to remove ch