ページ1に含まれる内容の要旨
Pulsar Esprit
3–13.5 kVA
High Availability UPS for Internet Servers
Advanced Features
w High availability power
+ maximum reliability=
MGE Power Cluster
w Web-based management
using XML
w Standard USB
communications
w Seamless integration
with Microsoft
Windows 2000
w Redundant battery
back-up potential
MGE UPS SYSTEMS all new Pulsar Esprit has been specifically
w Redundant
designed to meet the needs of Internet Service Providers & Application
battery chargers
Service Providers. Esprit provi
ページ2に含まれる内容の要旨
Maximum Availability and Reliability Power redundancy for servers with multiple power supplies Most servers provide multiple power supplies for N+1 redundancy. To maintain high availability of the system when considering power, a redundant configuration as offered with the Esprit Power Cluster is better than traditional N+1 redundant UPSs: Configuration Comments 1 Single point of failure Traditional redundant UPSs are paralleled at their outputs and provide a worrisome single point of failure. 2
ページ3に含まれる内容の要旨
Easy Connections and Installation Plug-In convenience up to 9 kVA Simple installation: simply plug the system in, up to 9 kVA Electronic Module (Esprit 3.1) Esprit 3.1 Esprit 4.5 Esprit 6 Esprit 9 (L5-30) (5-50) (L14-30) (14-50) Multiple Rack Mounting Communications ports Esprit’s unique design lets you stack up w RS232 port electronic and battery modules as you w USB port want (up to 3 max.). A 5U rack mount kit that can accommodate 2 modules is available as an option. Redundant battery path V
ページ4に含まれる内容の要旨
Internet-Grade Monitoring and Communications All Esprit models come standard with built-in communications capabilities using either an RS232 or USB port. UPS-to-server communications is essential to secure the operation of your operating system during an extended power failure. The UPS will signal the O/S when its batteries are almost depleted to launch an orderly, graceful shutdown process to make sure all files are protected. This feature is vital for systems running unattended, such as Web se
ページ5に含まれる内容の要旨
Select the Esprit you need for your Web Servers Power Cluster Model Single UPS (for servers with 2 redundant power supplies*) w 3-server protection w 3-server protection Esprit 3.1 w 3.0 kVA w 3.0 kVA w 5U (in rack) w 10U (in rack) w Expand load to 6 kVA (with no redundancy) w 5-server protection w 5-server protection Esprit 4.5 w 4.5 kVA w 4.5 kVA w 5U (in rack) w 10U (in rack) w Expand load to 9 kVA (with no redundancy) w 6-server protection w 6-server protection Esprit 6 w 6 kVA w 6 kVA w
ページ6に含まれる内容の要旨
Pulsar Esprit Specifications Esprit 13.5 Power Cluster Esprit 4.5 Dimensions and Weights Single UPS Power Cluster (for servers with 2 redundant power supplies) Model Dimensions Weight Dimensions Weight WxHxD (in.) (lbs.) WxHxD (in.) each (lbs.) each Esprit 3.1 Electronic 1 ea. 8.5" x 7.25" x 19" 20 2 ea. 8.5" x 7.25" x 19" 20 Battery 1 ea. 8.5" x 7.25" x 19" 80 2 ea. 8.5" x 7.25" x 19" 80 Esprit 4.5 Electronic 1 ea. 8.5" x 7.25" x 19" 20 2 ea. 8.5" x 7.25" x 19” 20 Battery 1 ea. 8.5" x 7.25" x 1