Always “On” UPS Systems Inc.
GES L-Series – Single Phase Input, Single Phase Output
Uninterruptible Power Supply
USER MANUAL
Version 1.4
GES-801L, GES-102L, GES-152L, GES-202L, GES-302L
Line Interactive (True Sine Wave):
800VA, 1000VA, 1500VA, 2000VA, 3000VA
Extended Run-Time Battery Banks
Available on All Models
ページ2に含まれる内容の要旨
Always “On” UPS Systems Inc.
ページ3に含まれる内容の要旨
Always “On” UPS Systems Inc. SAVE THESE INSTRUCTIONS This manual contains important instructions for the GES-801L, GES-102L, GES-152L, GES-202L, GES-302L and should be followed during installation and maintenance of the UPS and batteries. The UPS contains voltages that are potentially hazardous. Please contact our dealers or qualified personnel for service. Servicing of the batteries should be performed or supervised by personnel knowledgeable with batteries and the required precaut
ページ4に含まれる内容の要旨
Always “On” UPS Systems Inc. TABLE OF CONTENTS INTRODUCTION ........................................................................................................................................ 5 SAFETY INSTRUCTIONS......................................................................................................................... 6 PRESENTATION ...........................................................................
ページ5に含まれる内容の要旨
Always “On” UPS Systems Inc. Introduction The L-Series is a Line Interactive UPS system that includes the newest and latest technology enhancements. The Line Interactive technology with AVR function (on- line voltage boost-up & buck-down) allows for a wide input voltage range of 90 to 150VAC. The L-Series UPS is the ideal protection for microprocessor controlled loads. With the utility power connected, the charger begins to operate immediately, charging the battery. In the event of a
ページ6に含まれる内容の要旨
Always “On” UPS Systems Inc. Safety Instructions The UPS has its own internal energy source (batteries), therefore the output receptacles may have electricity present even though the UPS is disconnected from the utility power. The DC voltage provided from the internal batteries are as follows: a) GES-801L 24VDC d) GES-202L 48VDC b) GES-102L 24VDC e) GES-302L 48VDC c) GES-152L 36VDC Isolated Ground Wire refers to the bare wire connecting electrical equipment to ground. The isola
ページ7に含まれる内容の要旨
Always “On” UPS Systems Inc. Presentation Front Panel 1. POWER bar graph (BATTERY CHARGE/LINE VOLTAGE) This displays the present battery charge as a percentage of battery capacity. It also displays the utility line voltage. 2. LOAD bar graph This displays the amount of power required by the load as a percentage. 3. "OVERLOAD" indicator (RED LED) This LED lights when the load(s) connected to the UPS exceed the UPS's capacity. See Section 6.3 for solution to this problem. 4. "BUCK
ページ8に含まれる内容の要旨
Always “On” UPS Systems Inc. Rear Panel 11. TELEPHONE/MODEM/ETHERNET SURGE PROTECTION Surge protection for telephone line, modem line, and 10BaseT line to maintain a completely safe connection for INTERNET/INTRANET service. 12. EXTERNAL BATTERY PACK CONNECTOR (optional) Allows for extended runtime. Caution: Use only factory supplied or authorized connecting cable for external battery pack! 13. SNMP INTERFACE PORT (optional) This option will allow the UPS to be connected direct
ページ9に含まれる内容の要旨
Always “On” UPS Systems Inc. 16. INPUT CIRCUIT BREAKER It trips when the connected loads exceed the protected receptacle's capacity. The center plungers of the circuit breakers extend when tripped. 17. SITE WIRING FAULT INDICATORS (RED LED) It illuminates when the UPS is connected to an improperly wired AC power outlet. Note: This device is available on 120 VAC model only. 18. COMPUTER INTERFACE Provides both RS-232 and relay signal to support NOVELL, UNIX, DOS, WINDOWS and other
ページ10に含まれる内容の要旨
Always “On” UPS Systems Inc. Installation Unpacking and Inspection Examine the packaging for damage. Inform the carrier immediately if and/or when damage is noticed. Retain the packaging for future use. Placement Install the UPS in a protected area with adequate airflow and free of excessive dust. Do not operate the UPS where the temperature and humidity is outside the specified limits. Connect Computer Interface (optional) UPSilon 2000 (or selected option) and an interface kit c
ページ11に含まれる内容の要旨
Always “On” UPS Systems Inc. Connecting the Telephone/Modem/Ethernet Lines Connect a telephone line, modem line, or 10BaseT line into the telephone/modem/Ethernet surge protection sockets on the back of the UPS. The RJ-45/RJ-11 modular sockets accept standard single line telephone connections and 10BaseT connectors. This connection will require another length cable. Note: This connection is optional. It is not necessary to use this with the UPS. Caution: The line current limiting fea
ページ12に含まれる内容の要旨
Always “On” UPS Systems Inc. Operation Switching “On” the UPS With the UPS plugged in, press and hold the “ON/TEST” button for at least 1 second to switch the UPS on. The UPS will perform a self-test each time it is switched on. Note: When switched off, and still plugged into utility, the UPS maintains the battery charge and will respond to commands received through the computer interface port. Switching “Off” the UPS Press and hold the “OFF” button until the "LINE NORMAL" or "BAC
ページ13に含まれる内容の要旨
Always “On” UPS Systems Inc. Battery Charge Bar Graph This 5 LED display indicates the present charge of the UPS's batteries as a percentage of the total battery capacity. When all five LED’s are lit, the batteries are fully charged. When only two of the LED’s are lit, the batteries can supply less than two minutes of power to the load. Cold Start When the UPS is off, and there is no utility power, use the cold start feature to apply power to the loads from the UPS's battery. Press an
ページ14に含まれる内容の要旨
Always “On” UPS Systems Inc. Software Options UPSilon 2000 Software The UPSilon 2000 software utilizes standard RS-232 interface to perform monitoring functions, and provides an orderly shutdown of a computer system in the event of power failure. Moreover, UPSilon 2000 displays all the diagnostic symptoms through a graphical interface, such as Voltage, Frequency, Battery Level, etc. The software is available for DOS, Windows 3.x, Windows 95/98/00 & Windows NT V3.5 or later, FreeBSD,
ページ15に含まれる内容の要旨
Always “On” UPS Systems Inc. Computer Interface Port The computer interface port has the following characteristics: The communication port on the back of the UPS may be connected to a host computer. This port allows the computer to monitor the status of the UPS and control the operation of the UPS. Its major functions include the following: 1. The ability to broadcast a warning when the power fails. 2. The ability to close any open files before the battery reserves are exhausted. 3
ページ16に含まれる内容の要旨
Always “On” UPS Systems Inc. Battery Replacement Your batteries should run anywhere from 3-5 years before they need to be replaced. Please follow the instructions below for easy, trouble free, battery replacement. 1. Turn the UPS off (follow procedure previously mentioned) 2. Unplug the UPS from utility power source and disconnect all connected loads. 3. Disconnect AC power cord from unit. 4. Using a phillips screw driver, unscrew the screws holding the top of the unit to the botto
ページ17に含まれる内容の要旨
Always “On” UPS Systems Inc. Troubleshooting Please follow the guidelines below for solutions to common problems: Check UPS input plug and wiring. Check UPS input voltage. Please prepare the information as follows for service personnel: UPS model number and serial number Description of problem(s) in detail. General Problems Problems Possible causes Solution Fuse/Breaker at back panel open Replace Fuse/Switch breaker on UPS has no reaction No AC input Check AC power
ページ18に含まれる内容の要旨
Always “On” UPS Systems Inc. Storage Storage Conditions Store the UPS covered and upright in a cool, dry location, with its battery fully charged. Before storing, charge the UPS for at least eight (8) hours. Remove any accessories from the accessory slot and disconnect any cables connected to the computer interface port to avoid unnecessary drain on the battery. Extended Storage During extended storage periods in environments where the ambient temperature is -15 to +30°C (+5 to +8
ページ19に含まれる内容の要旨
Always “On” UPS Systems Inc. Battery Bank Installation Install up to 8 battery banks per L Series UPS following the instructions below. 1 2 3 4 BLACK RED Caution: Make sure the UPS is shutdown and unplugged before connecting additional Battery Packs (refer to Switching the UPS “Off” section, page 11) 1. Locate the external battery connector located at the rear of the UPS. 2. Make sure you are connecting the connector correctly or
ページ20に含まれる内容の要旨
Always “On” UPS Systems Inc. Specifications Specification MODEL NO. GES-801L GES-102L GES-152L GES-202L GES-302L Comparison MAXIMUM CAPACITY 800VA / 560W 1kVA / 700W 1.5kVA / 1050W 2kVA / 1400W 3kVA / 2100W GENERAL UPC ORDER CODE 825433 22100 825433 22200 825433 22300 825433 22400 825433 22500 NOMINAL VOLTAGE 120VAC (220 optional) INPUT VOLTAGE RANGE + / - 25% FREQUENCY RANGE 50 or 60 Hz auto-sensing + / - 5% NOMINAL VOLTAGE 120VAC AUTO VOLTAGE REGULATION +15% for 90 - 109VAC