ページ1に含まれる内容の要旨
Powerware 3105 UPS
UserÊs manual
1
UserÊs Manual 350-700VA Rev B
ページ2に含まれる内容の要旨
©2006 Eaton Corporation All Rights Reserved The contents of this manual are the copyright of the publisher and may not be reproduced (even extracts) unless permission granted. Every care has been taken to ensure the accuracy of the information contained in this manual, but no liability can be accepted for any errors or omission. The right to make design modifications is reserved. 2 UserÊs Manual 350-700VA Rev B
ページ3に含まれる内容の要旨
Powerware 3105 UPS UserÊs manual 1023921 Revision B Contents Introduction .................................................................................................................. 4 Features .................................................................................................................... 4 Unit inspection .......................................................................................................... 4 Safety Instructions ................................
ページ4に含まれる内容の要旨
Introduction The Powerware 3105 uninterruptible power system (UPS) filters the input line from line disturbances and protects your sensitive electronic equipment from three common power problems such as power failures, power sags and power surges. Features: Six outlets - Three with surge and battery backup protection - Three with surge protection only Data Line (Internet faxmodemDSL) or telephone line surge protection jacks Cold Start capability Proprietary LanSafe Power manage
ページ5に含まれる内容の要旨
Safety Instructions ATTENTION ! Maintenance, other than battery replacement must be performed by a qualified technician. Failure to do so could result in an electrical shock. Although the unit may be unplugged from utility power, hazardous voltage still may be present through the battery. 1. Place the Powerware 3105 UPS indoors in an area that has adequate airflow and is free of excessive dust. Do NOT allow the UPS to be exposed to moisture, rain, excessive heat, or direct sunlight. 2. Use of
ページ6に含まれる内容の要旨
Battery connection required before use! Connecting the Battery: Principle shown below. For detailed information how to connect, please refer to battery replacement section. Installation and Operation: The following steps explain how to connect and operate the Powerware 3105 UPS. 1. Connect the UPS to a grounded power outlet. Note It is recommended that the battery should be charged for minimum 8 hours to ensure full charge before placing the UPS in service. 2. Plug your computer, monitor or lo
ページ7に含まれる内容の要旨
Indicators 5 1 2 3 4 1. On/Off Push Button/Test Switch One switch controls the power to your equipment. Upon power turn on, unit performs a self-test to detect overload or undercharged conditions. Turn on the UPS Press and hold the push button switch depressed for more than one second. Release the switch after the audible beep is sounded. Turn off the UPS Press and hold the push button switch for more than one second and release the switch after the audible beep is sounded. The UPS will
ページ8に含まれる内容の要旨
9 6 7 8 6. RJ11 Phone/Fax Protection Connectors 7. USB Communication Port The provided LanSafe monitoring and shutdown software can be automatically configured to save your files and shut down your computer in the event of a prolonged power outage. Your personal computer can receive the status as utility power line, utility power failure, on battery and low battery by contact closure signals that are sent through the USB port. 8. Circuit Breaker (resetable) The button protrudes out when a
ページ9に含まれる内容の要旨
700VA model (12V- 7Ah battery) Status Indicators The UPS provides both visual and audible status indicators. Visual indicators consist of three LEDs to represent the following conditions: On utility power operation On battery power operation UPS fault/alarm 9 UserÊs Manual 350-700VA Rev B
ページ10に含まれる内容の要旨
LED & Alarm Status Table UPS status Green LED Red LED Buzzer Self test Blink 1 (by turns) B1 Charging ON OFF OFF Charge off ON OFF OFF AC (Utility mode Low battery ON Blink 2 B5 Over load ON Blink 2 B4 Normal Blink 2 OFF B1 DC (Battery Over load Blink 2 OFF B1 Mode) Low battery Blink 2 Blink 2 B3 Short/Fault/DC Over-Bat OFF ON ON AC Over-Bat/Bat Fault OFF Blink 2 B5 Notes: Blink 1: ON 0.5 seconds / OFF 0.5 seconds Blink 2: ON 0.25 seconds / OFF 0.25 seconds B1: 1 beep / 5 seconds ON 0.25 seconds
ページ11に含まれる内容の要旨
Troubleshooting Symptom Possible Cause Action to Take The battery is disconnected Connect the battery (see Connect and utility power is not Battery) and ensure power is available at the wall outlet. available at the wall outlet. UPS will not turn on Reduce the amount of equipment Input Circuit Breaker has plugged into the outlets of the UPS. tripped. Next, reset the circuit breaker by pushing the plunger back in. UPS is making a The „Battery Backup & Turn off the UPS and reduce the continu
ページ12に含まれる内容の要旨
Head Office Eaton Power Quality Pty Ltd ABN 82 054 056 709 10 Kent Road, Mascot NSW 2020 Sales Offices Queensland Victoria Western Australia/NT South Australia Sales Phone: 1300 UPS UPS Sales Email: info.au@powerware.com National Service Centre: 1300 303 059 www.powerware.com.au 12 UserÊs Manual 350-700VA Rev B