ページ1に含まれる内容の要旨
®
Powerware 9315 UPS
500–750 kVA
Installation and Operation Manual
ページ2に含まれる内容の要旨
IMPORTANTSAFETYINSTRUCTIONS SAVETHESEINSTRUCTIONS Thismanualcontainsimportantinstructionsthatyoushouldfollowduringinstallationandmaintenanceof theUPSandbatteries.Pleasereadallinstructionsbeforeoperatingtheequipmentandsavethismanualfor futurereference. CONSIGNESDESÉCURITÉIMPORTANTES CONSERVERCESINSTRUCTIONS Cemanuelcomportedesinstructionsimportantesquevousêtesinvitéàsuivrelorsdetouteprocédure d’installationetdemaintenancedesbatteriesetdel’onduleur.Veuillezconsulterentièrementces instructionsavant
ページ3に含まれる内容の要旨
SpecialSymbols The following are examples of symbols used on the UPS or accessories to alert you to important information: RISKOFELECTRICSHOCK-Indicates that a risk of electric shock is present and the associated warning should be observed. CAUTION: REFERTOOPERATOR’SMANUAL -Refer to your operator’s manual for additional information, such as important operating and maintenance instructions. This symbol indicates that you should not discard the UPS or the UPS batteries in the trash. This product c
ページ4に含まれる内容の要旨
This page intentionally left blank.
ページ5に含まれる内容の要旨
Table of Contents 1 Introduction ........................................................................... 1-1 1.1 UPSFeatures ......................................................................................... 1-2 1.1.1 InstallationFeatures ............................................................................... 1-2 1.1.2 CustomerInterface ................................................................................ 1-2 1.1.3 CustomerConvenienceOutlet..........................
ページ6に含まれる内容の要旨
TABLE OF CONTENTS 6 InstallingOptionalAccessories ........................................................... 6-1 6.1 InstallinganRMP ...................................................................................... 6-2 6.2 InstallinganRIM ...................................................................................... 6-5 6.3 InstallinganSCM ...................................................................................... 6-7 6.4 InstallingX-SlotCards............................
ページ7に含まれる内容の要旨
TABLE OF CONTENTS 11 RespondingtoSystemEvents ............................................................. 11-1 11.1 SystemEventHorns .................................................................................... 11-1 11.2 SystemEventIndicators ................................................................................. 11-1 11.3 SystemEventMessages ................................................................................. 11-1 12 Communication ................................
ページ8に含まれる内容の要旨
TABLE OF CONTENTS 14 ProductSpecifications .................................................................. 14-1 14.1 ModelNumbers ....................................................................................... 14-1 14.2 UPSSystemInput ...................................................................................... 14-1 14.3 UPSSystemOutput..................................................................................... 14-2 14.4 EnvironmentalSpecifications...................
ページ9に含まれる内容の要旨
List of Figures Figure1-1.TypicalPowerware9315(500–750kVA)UPSSystem .................................................. 1-1 Figure2-1.CabinetasShippedwithOuterPackagingandPallet................................................... 2-2 Figure4-1.RemoteBatteryDisconnectEnclosure ............................................................. 4-1 Figure5-1.RemoteEmergencyPower-off(REPO)Control ........................................................ 5-1 Figure5-2.REPOWiring .............................
ページ10に含まれる内容の要旨
LIST OF FIGURES FigureA-10.SecuringCables ........................................................................... A-18 FigureA-11.CB2TBtoDCSourceDisconnectDevice........................................................... A-21 FigureA-12.Inverter/RectifierCabinet–PCM1Terminals....................................................... A-22 FigureA-13.Inverter/RectifierCabinet–PCM1Terminals(continued) .............................................. A-23 FigureA-14.Output/InverterCabinet–PCM2Termina
ページ11に含まれる内容の要旨
Chapter 1 Figure1Table1 Introduction ® ® The Eaton Powerware 9315 (500–750 kVA) uninterruptible power supply (UPS) is an online power protection system that prevents loss of valuable electronic information, minimizes equipment downtime, and minimizes the adverse effect on equipment production because of unexpected power problems. The Powerware 9315 UPS system continually monitors incoming electrical power and removes the surges, spikes, sags, and other irregularities that are inherent in commerc
ページ12に含まれる内容の要旨
INTRODUCTION 1.1 UPS Features The UPS has many standard features that provide cost-effective and consistently reliable power protection. The descriptions in this section provide a brief overview of the UPS standard features. 1.1.1 Installation Features Power wiring can be routed through the top of each cabinet. External sensing and monitoring control wire must be installed according to UL Class I requirements. Class I wiring can be routed through the top of each cabinet. 1.1.2 Customer Interface
ページ13に含まれる内容の要旨
INTRODUCTION 1.2 Options and Accessories Contact your Eaton sales representative for information about the following options: 1.2.1 5% Input Filter The UPS can be equipped with an input filter. An input filter yields power factor correction that allows you to save on your initial installation and operating costs. The filter also reduces input harmonic current distortion and minimizes upstream interference that can damage sensitive hardware components. 1.2.2 Battery Racks You can enhance the prot
ページ14に含まれる内容の要旨
INTRODUCTION 1.2.6 Monitoring and Communication The following monitoring and communication options are available: S RemoteMonitorPanel(RMP) – An optional RMP contains backlit status indicators and a local horn, allowing you to monitor the UPS operational status and alarm condition from virtually any location within your facility. This option is described further in Chapter 10, “Using Features and Options.” S RelayInterfaceModule(RIM) – An optional RIM uses relay contact closures to indicate the
ページ15に含まれる内容の要旨
INTRODUCTION 1.4 Safety Warnings IMPORTANTSAFETYINSTRUCTIONS SAVETHESEINSTRUCTIONS S Thismanualcontainsimportantinstructionsthatshouldbefollowedduringinstallationandmaintenance oftheUPSandbatteries.Pleasereadallinstructionsbeforeoperatingtheequipmentandsavethis manualforfuturereference. S TheUPScabinetisdesignedforindustrialorcomputerroomapplicationsandcontainssafetyshields behindthefrontdoors.However,theUPSsystemisasophisticatedpowersystemandshouldbehandled withappropriatecare. DANGER ThisUPSco
ページ16に含まれる内容の要旨
INTRODUCTION AVERTISSEMENT! S Lesbatteriespeuventprésenterunrisquededéchargeélectriqueoudebrûlurepardescourts-circuitsde hauteintensité.Prendrelesprécautionsnécessaires. S Pourleremplacement,utiliserlemêmenombreetmodéledesbatteries. ATTENTION! S Unemiseaurebutréglementairedesbatteriesestobligatoire.Consulterlesrèglementsenvigueurdans votrelocalité. S Nejamaisjeterlesbatteriesaufeu.L’expositionauxflammesrisquedelesfaireexploser. 1.5 Conventions Used in This Manual This manual uses these type conv
ページ17に含まれる内容の要旨
INTRODUCTION 1.7 Getting Help If you need help with any of the following: S Scheduling initial startup S Regional locations and telephone numbers S A question about any of the information in this manual S A question this manual does not answer Please call the Eaton Help Desk for Powerware products at: United States: 1-800-843-9433 or1-919-870-3028 Canada: 1-800-461-9166 ext 260 All other countries: Call your local service representative ® EATON Powerware 9315 UPS (500–750 kVA) Installation and O
ページ18に含まれる内容の要旨
INTRODUCTION This page intentionally left blank. ® 1-8 EATON Powerware 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201691 Rev 1 www.powerware.com
ページ19に含まれる内容の要旨
Section I Installation ® EATON Powerware 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201691 Rev 1 www.powerware.com 1-1
ページ20に含まれる内容の要旨
® 1-2 EATON Powerware 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201691 Rev 1 www.powerware.com