ページ1に含まれる内容の要旨
ページ2に含まれる内容の要旨
920-007-12 Table of Contents Introduction Economizing Tips ............................................................................................................................................................................................................................ 3 WS models How to operate your Friedrich room air conditioner ...........................................................................................................................................................
ページ3に含まれる内容の要旨
920-007-12 WELCOME to years of economical comfort Your new Friedrich Room Air Conditioner has been carefully 5. Install weather stripping (metal is preferable to felt) around engineered and man u fac tured to give you many years of de pend able, exterior doors and windows. effi cient operation, keeping your room at a comfortable temperature 6. Have a fi replace? Be sure the damper is closed during air and hu mid i ty level. Many extra fea tures have been built into your conditioner operation.
ページ4に含まれる内容の要旨
920-007-12 WS model s Circuit Rating, Breaker Model Plug Type or Time Delay Fuse WS08, WS10, WS14 NEMA No. 5-15P 125V-15 AMP WS10, WS13, WS16 NEMA No. 6-15P 250V-15 AMP Figure 1 How to operate your Friedrich room air con diti on er Figure 2 PM 72 1 Power 2 3 4 Cool Fan ® MoneySaver Speed Mode 8 9 6 Fan Only 7 Clock 5 Timer Set Start Time 13 On/Off Hour Stop Time Temp/Hour 10 11 12 To start unit ® 2 Touch the Mode button once to activate the MoneySaver If your air conditioner is installed and
ページ5に含まれる内容の要旨
920-007-12 To adjust temperature To set the timer ® NOTE: Set the HOUR CLOCK (Set Hour) before attempting to set 4 Use the Mode button to select either the Cool or MoneySaver timer functions. function You can set the Start Time and Stop Time a minimum of one hour 5 COOLER – Touch the button to lower the room air apart, and a maximum of 23 hours apart. temperature. 11 After setting the time, press the Set Hour button once (Start 6 WARMER – Touch the button to raise the room air li
ページ6に含まれる内容の要旨
920-007-12 How to use the remote control To start unit To set the timer NOTE: You can set the START and STOP times a minimum of one 1 POWER - Press the Power button once. The unit will automatically hour apart, and a maximum of 23 hours apart. start in the mode and fan speed it was last left on. 9 TIMER START - Press Start to view the current start time for To set mode of operation cooling. Continue pressing the START button until you arrive at 2 CO OL - Press the Cool button to automati
ページ7に含まれる内容の要旨
920-007-12 WE and WY models Figure 4 Fan Off Only Low Low Heat Cool Med Med Heat Cool High High Heat Cool MAX MAX HEAT COOL ! Allow 3 min. between restarts Circuit Rating, Breaker Model Plug Type or Time Delay Fuse WE10, WE13, WE16, WY10, WY13 NEMA No. 6-20P 250V-20 AMP Mode control Temperature control Turn the knob clockwise to High Heat for heating with highest fan This knob controls the thermostat – turn clockwise to set a cooler speed. Set to Med Heat for heating with medium fan speed. Tu
ページ8に含まれる内容の要旨
ページ9に含まれる内容の要旨
Rotate 920-007-12 1" Diameter Plug Figure 6 WSC Sleeve 2 2 2 Airflow Decorative Front 1 1 1 Discharge Grille Return Air Grille All Friedrich room air conditioners are shipped from the factory with a Leakage Current Detection Interrupter (LCDI) equipped power NOTE: Your LCDI device will resemble one of these illustrations. cord. The LCDI device meets the UL and NEC requirements for cord connected air conditioners effective August 2004. To test your power supply cord: RESET TEST 1. Plug pow
ページ10に含まれる内容の要旨
920-007-12 Troubleshooting tips and home maintenance Won’t cool Frosting of the indoor coil If the unit operates, but won’t cool, determine if the controls are Certain operating conditions may produce indoor coil frost. During properly set. Wait three minutes before setting the therm ost at to a the cooling operation, a dirty fi lter or restricted air distribution in cooler position in order to check control settings. Check the fi lter and combination with cool, damp weather could cause such an
ページ11に含まれる内容の要旨
ページ12に含まれる内容の要旨
920-007-12 Installation requirements STEP 1 The WSC SLEEVE should be positioned so that the STEP 4 The WSC SLEEVE must also be installed with a downward 9 DRAIN EXTENSION extends a minimum of ⁄ " beyond 16 tilt toward the outside of the building. If a level is placed the OUTSIDE WALL (See Figure 8). so that it rests on the FRONT and BACK UNIT REST as shown in Figure 9, a properly installed unit provides a ½ STEP 2 The WSC SLEEVE must extend a minimum of ⅞" beyond bubble slope to the out
ページ13に含まれる内容の要旨
ページ14に含まれる内容の要旨
920-007-12 WallMaster chassis installation instructions for WS, WE and WY models (WSC-B sleeve) These instructions are provided for installation of WallMaster air STEP 2 Check the electrical receptacle to see that it conforms to conditioner chassis models into thru-the-wall sleeves. This chassis the requirements for the chassis model to be in stalled. has been UL approved with the sleeve listed on the serial nameplate See pages 2 and 5, for the re cep tac le requirements. of this chassis.
ページ15に含まれる内容の要旨
920-007-12 STEP 5 CHASSIS SEAL GASKET INSTALLATION: After STEP 6 Remove the intake grille from the decorative front frame by installing the shell, slide the chassis into the shell stopping grasping it at the upper right and left side corners. Pull out approximately 3" from full insertion. Stuff the chassis seal until the grille is released from the upper retaining snaps. gasket one inch deep between the chassis and the shell Tilt it down toward you, lift up and out of the bottom retaining
ページ16に含まれる内容の要旨
920-007-12 Condensate removal (WS, WE and WY models) If you desire to drain condensate from the basepan during unit STEP 2 Remove the knockout in the lower right side of the rear operation, this unit is provided with a drain nipple that can be grille. Slide the chassis into the WSC SLEEVE so that attached to the basepan. You must provide a 3/8" outside diameter the drain nipple extends through the knockout. thin-wall plastic or copper tube which will attach to the drain nipple. Follow the
ページ17に含まれる内容の要旨
920-007-12 Friedrich Air Conditioning Company P.O. Box 1540 San Antonio, TX 78295 210.357.4400 www.friedrich.com WALLMASTER THRU-THE-WALL AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible for service. Any additional labor cost for removing inac
ページ18に含まれる内容の要旨
920-007-12 Friedrich wants you to remain pleased with your Room Air Conditioner. Should further assistance be needed con cern ing this warranty, contact: RAC Warranty, Service and Parts Friedrich Air Conditioning Co. P.O. Box 1540 San Antonio, TX 78295-1540 Your personal warranty registration record WARRANTY REGISTRATION: Please complete and return your Warranty Reg is tra tion Card (not this form) immediately and mail to FRIEDRICH. While it is not required that you do so in order to obtai
ページ19に含まれる内容の要旨
ページ20に含まれる内容の要旨
920-007-12 Bienvenido Sugerencias para economizar sus gastos de aire acondicionado ....................................................................................................................................... 21 Los mod elos WS Como hacer funcionar su unidad de aire acondicionado Friedrich .............................................................................................................................................. 22 Para arrancar la unidad .............................