ページ1に含まれる内容の要旨
USE AND CARE
MANUAL
MANUEL
D'UTILISATION
Models • Modèles
DAC7077EE
DAC8007EE
DAC10007EE
DAC12077EE
DAC12507EE
Room Air Conditioner
Table of contents . . . . . . . . . . . . . . . . . . . . . . . 1
CAUTION:
Climatiseur de pièce
Read and Follow All Safety Rules
and Operating Instructions Before Table of contents . . . . . . . . . . . . . . . . . . . . . . . 12
First Use of This Product.
PRÉCAUTION:
Veuillez lire attentivement
les consignes de sécurité et les
instructions d'utilisation avant
l'u
ページ2に含まれる内容の要旨
ページ3に含まれる内容の要旨
Introduction Thank you for choosing a Danby Room Air Conditioner to cool your home. This Use and Care Manual provides information necessary for the proper care and maintenance of your new Room Air Conditioner. If properly maintained, your air conditioner will give you many years of trouble free operation. To avoid installation difficulties, read these instructions completely before installing/operating your unit. NOTE: This unit is NOT designed for through-the-wall installation. For easy referen
ページ4に含まれる内容の要旨
Electrical Specifications 1. All wiring must comply with local and national electrical codes and must be installed by a qualified electrician. If you have any questions regarding the following instructions, contact a qualified electrician. 2. Check available power supply and resolve any wiring problems BEFORE installing and operating this unit. 3. This 115V air conditioner uses 10.1 or less (depending on model) nameplate amps and may be used in any properly wired, general purpose household recep
ページ5に含まれる内容の要旨
Energy-Saving Tips Your Room Air Conditioner is designed to be highly efficient in energy savings. Follow these recommendations for greater efficiency. 4. Start your air conditioner before outdoor air 1. Select thermostat setting that suits your becomes hot and uncomfortable. This avoids an comfort needs and leave thermostat at that initial period of discomfort while unit is cooling chosen setting. off the room. 2. The filter is very efficient in removing airborne 5. When outdoor temperatures
ページ6に含まれる内容の要旨
CAUTION Your unit is designed to evaporate condensation under normal conditions. However, under Because the compressor is located towards the extreme humidity conditions, excess condensation rear of the unit, this side will be heavier and more may cause basepan to overflow to the outside. awkward to manipulate. Therefore, it is The Unit should be installed where condensation recommended to have someone assist you run-off cannot drip on pedestrians or neighboring during the installation of this
ページ7に含まれる内容の要旨
Slide down into guide 1. Assembly of the Upper Channel, to 3a. Completing the Installation (cont’d) Cabinet. (Factory installed on some models) • Carefully place the air conditioner into the window with the “L” shaped mounting bracket • "L" Shaped Top Channel: Install the "L" (on top) positioned in front of the upper window shaped channel to the top of the cabinet as sash. The bottom of the cabinet should be shown in Fig. 3 using four (4) 3/8"(9.5mm) screws. positioned on the “recesse
ページ8に含まれる内容の要旨
Key Pad Features LED DISPLAY Temp/Timer LED DISPLAY: Displays the following information Control independently; Set Temperature, Ambient Room Temperature and Auto Timer On/Off settings. Auto 68 Timer POWER: Turns unit On / Off. MODE: Allows you to scroll through and select MODE the desired operating mode; Cool , Dry , Sleep Auto Fan Only and *Auto . Mode Check The selected mode will be denoted by the Filter adjacent indicator light. *‘Auto’ is a pre-set factory program that automatically defines
ページ9に含まれる内容の要旨
MODE Remote Control Features Electronic Electronic Display: Displays the following Display A information; A: Remote Control power On/Off and Mode Icons B C B: Clock and Auto-Timer settings 1 D C: Current set temperature 2 D: Fan speed setting 3 Control Buttons 4 5 1. Power switch. 2. Mode 7 © 3. Fan Speed 6 9 4. Energy Saver 8 5. Auto-Timer 11 6. Used to increase or decrease temperature 10 12 settings in 1° increments on the Celsius or Fahrenheit scale. To operate the hand held remote con
ページ10に含まれる内容の要旨
Care and Maintenance End-of-Season Care 1. Operate the fan alone for half a day to dry out the When cleaning the air conditioner, be sure to inside of the unit. turn the POWER OFF and disconnect the power 2. Turn off power and remove plug from wall socket. cord from the electrical outlet. 1. DO NOT use gasoline, benzine, thinner or other 3. Clean filter. chemicals on the air conditioner as these 4. Store (covered) air conditioner in a dry location. substances may cause damage to the paint finish
ページ11に含まれる内容の要旨
Troubleshooting Guide Frequently, a problem is minor and a service call may not be necessary, use this troubleshooting guide for a possible solution. If the unit continues to operate improperly, call Danby’s Toll Free Number 1-800-263-2629 for assistance, or call one of our service depots listed in the enclosed “Authorized Service Depot” listing provided with this unit. Difficulty Possible Cause Suggested Solution Air conditioner will No power to unit. Check connection of power cord to not oper
ページ12に含まれる内容の要旨
ページ13に含まれる内容の要旨
Room Air Conditioner The model number of your room air conditioner is found on the serial plate located on the right side of the unit above the power cord. Model • Modèle All repair parts are available for purchase or special order when you visit your nearest service depot. To request service and/or the location of the service depot nearest you, call the TOLL FREE NUMBER: 1-800-263-2629 When requesting service or ordering parts, always provide the following information: DAC7077EE • Product Typ