ページ1に含まれる内容の要旨
MODEL NUMBERS
SELECTRONIC™
6065.22X
6065.26X
PROXIMITY TOILET
6067.22X
6067.26X
CONCEALED FLUSH VALVE 6068.22X
6068.26X
1.28 & 1.6 GPF
Concealed Flushometer
for 1-1/2" Top or Back Spud Bowls
CLOG RESISTANT
• Self-cleaning piston valve prevents clogging and reduces maintenance.
ONE SENSOR FITS ALL
• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and
flush valves.
• Range can be adjusted manually or with optional remote control.
Certified to comply with ASME A112.19.2M
• Sensor
ページ2に含まれる内容の要旨
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. All American Standard Products Are Water Tested At Our Factory. UNPACKING Some Residual Water May Remain In The Valve During Shipping. 1. Remove the Flush Valve items from the carton. The illustration below shows all items after they have been removed from the carton. Some items may be pack
ページ3に含まれる内容の要旨
Fig. 1 GENERAL DESCRIPTION: 25mm (1) MAX. SELECTRONIC™ Roughing-in Dimensions PROXIMITY TOILET FLUSH VALVE FINISHED WALL MAXIMUM DETECTION ZONE Concealed Flushometer 160mm 400mm-800mm TOP SPUD (6-1/4) (15-3/4 TO 31-1/2) for 1-1/2" Spud Fixtures TOILET Exclusive, self cleaning piston-type flush valve with proximity operation and manual 160mm override. Operates on DC (battery)or 127X127mm (6-1/4) (5X5 CUTOUT AC power. Recommended operating OVERRIDE 15˚ FOR BOX) BUTTON pressure 25psi (flowing)
ページ4に含まれる内容の要旨
INSTALL ELECTRICAL BOX Fig.3 (TOP SPUD FIXTURE ILLUSTRATED) 1 ASSEMBLY; Fig. 3 2 127mm (5) 1. Cut a 127x127mm (5"x 5") opening in finished wall for 127mm ELECTRICAL BOX (1) at the deminsion shown in Fig.3. (5) 2. Rotate the 4 MOUNTING TABS (2) flat against the 3 electrical box. Holding the MOUNTING TABS (2) in position install the ELECTRICAL BOX (1) into the opening. Fig. 3a Make sure the MOUNTING TABS (2) are behind the wall. TOP 3. Tighten the the 4 MOUNTING SCREWS (3) until the 40
ページ5に含まれる内容の要旨
4 INSTALL VACUUM BREAKER AND 4 Fig. 6 3 2 FLUSH CONNECTIONS; Fig. 6 3 4 1. Place the SPUD FLANGE (1) over the spud on the 1-1/2" TOP SPUD 1 Fixture. Fig. 6. 2. Thread SPUD COUPLING NUT (2) onto Spud. Make sure SEAL WASHER (4) and FRICTION WASHER (3) are installed. Do not tighten fully. Fig. 6. 3. Remove the COUPLING NUTS (6, 6a) from the Fig. 6a 7 CHROME ELBOW (5). Make sure you have a TAPERED 6a RUBBER WASHER (7), PLASTIC SUPPORT (8) and 5 SQUARE SEAL WASHER (9). Fig. 6a. TAPERED SIDE
ページ6に含まれる内容の要旨
5 INSTALL FLUSH VALVE; Fig. 8 Fig. 8 1. Insert the side ADJUSTABLE TAILPIECE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the TAILPIECE O-RING (4) with water if 3 necessary. Lightly tighten COUPLING NUT (5). Fig. 8. Important: Do not use lubricants (other than water) or any type of thread sealing paste or tape. 1 5 4 2 6 CONNECT FLUSH VALVE TO Fig. 9 121mm,+13mm, -6mm PIPING; Fig. 9 (4-3/4)(+1/2, -1/4) 7 1. Align the FLUSH VALVE (2) (Fig. 9) directly above the VACUUM BREAK
ページ7に含まれる内容の要旨
TOP CONNECT FRONT PANEL TO 7 Fig. 10 ELECTRICAL BOX (AC POWER); 1 Fig. 10 4 1. Remove the four COVER SCREWS (1) and COVER 2 from (2) ELECTRICAL BOX (4). Fig. 10. 2. Pull the CIRCUIT BOARD (3) out from ELECTRICAL BOX (4). Fig. 10. 3. Knock out lower blank in ELECTRICAL BOX (4) with flat blade screwdriver. Install from the back of 3 ELECTRICAL BOX (4) the POWER SUPPLY GROMMET (8). Fig. 10a. 4. Attach the SAFETY CHAIN (5) from the FRONT Fig. 10a TOP PANEL (6) to the MOUNTING POST (7) as s
ページ8に含まれる内容の要旨
TOP CONNECT FRONT PANEL TO 8 Fig. 11 ELECTRICAL BOX (DC POWER 1 BATTERY); Fig. 11 3 1. Remove the four COVER SCREWS (1) and COVER 2 (2) from ELECTRICAL BOX (3). Fig. 10. 2. Install BATTERY (4) into holder on DC circuit board. Press BATTERY (4) down (contacts facing downward) into 4 position until tabs lock BATTERY (4) into place. Fig. 11a TOP 3. Attach the SAFETY CHAIN (5) from the FRONT PANEL (6) to the MOUNTING POST (7) as shown. Feed the Red and Black wires through the back opening 3
ページ9に含まれる内容の要旨
CONNECT OVERRIDE HOSES, 10 Fig. 13 AC & DC POWER; Fig. 13 3 1. Push the BLACK HOSE (1) into the BOTTOM HOSE CONNECTOR (2) and the other end into the back of the BLACK 1 HOSE OVERRIDE SWITCH (3). 2. Push the BLUE HOSE (4) into the TOP HOSE 6 CONNECTOR (5) on the valve and the other end into the BOTTOM CONNECTOR (6) on the OVERRIDE SWITCH (3). BLUE 4 HOSE 5 2 CONNECT SOLENOID WIRING Fig. 14 11 AND POWER SUPPLY; Fig. 14 1. Push the RED WIRE CONNECTOR (1) onto the SOLENOID PIN (2) with
ページ10に含まれる内容の要旨
Fig. 15 Unit #1 Unit #2 Unit #3 13 13 TOP TOP TOP SENSOR SENSOR SENSOR WIRE WIRE WIRE 6 6 6 10 10 10 7 7 7 8 8 8 12 12 FOR AC-VERSION 12 Fig. 15a SENSOR WIRE (MULTI HOOK-UP); Fig. 15, 15a CONNECTOR Unit #1 1. Remove the COVER SCREWS (1) and COVER (2) from each ELECTRICAL BOX (3). TOP 2. See AC Version Electrical Hook-up for Unit #1 of the Multi hook-up. 5 6 4 3. Install SENSOR WIRE GROMMET (4) and FLUSH VALVE 10 SENSOR WIRE (5) into the COVER (2) of each unit. Insert 9 the flush valve
ページ11に含まれる内容の要旨
TOP HO 13 W TO INSTALL NEW BATTERY; Fig. 16 Fig. 16 4 TOP 1. Remove FRONT PANEL. For removing front panel see Step 9 for instructions. 1 5 2. Remove the four COVER SCREWS (1) and COVER 3 (2) from ELECTRICAL BOX (3). Fig. 16. 2 3. Disconnect GREY SENSOR WIRE (4) from CIRCUIT BOARD (5). 4. Remove CIRCUIT BOARD (5) from ELECTRICAL BOX (3). Fig. 16a. 5. With your thumbs, spread the two TABS (6) on battery holder apart and remove the BATTERY (7). Fig. 16a 2. Install NEW BATTERY (7) in
ページ12に含まれる内容の要旨
HO 15 W TO SET DETECTION RANGE Fig. 18 (If Required) ; Fig. 18 & 19 Note: The detection distance is preset and is ideal for 5 TOP most installations. Should an adjustment be required follow the steps below. 2 6 1. Remove FRONT PANEL (1). See Step 9 for removing front panel instructions. 4 3 2. Remove the four COVER SCREWS (2) and COVER (3) from ELECTRICAL BOX (4). Fig. 18. 3. Disconnect GREY SENSOR WIRE (5) from CIRCUIT BOARD. (6). 4. Keeping hands away from the front of the sensor,
ページ13に含まれる内容の要旨
M968550 REV. 1.5 12 UNIT DOES NOT FLUSH AT ALL UNIT WILL ONLY FLUSH MANUALLY IS STOP VALVE OPEN? NO OPEN VALVE LOOK FOR REPEATED DOUBLE FLASH ON SENSOR YES BATTERY LOW; YES REPLACE BATTERY NO SEE STEP 13, page 10 LOOK FOR REPEATED in manual DOUBLE FLASH ON SENSOR YES INSTALL NEW BATTERY 1. COVER SENSOR FOR 10 SECONDS 2. UNCOVER SENSOR FOR 10 SECONDS. NO RETRY AUTOMATIC FLUSH. TRY MANUAL VALVE BUTTON; DOES THE UNIT FLUSH? WILL THE UNIT FLUSH? NO REPLACE PISTON KIT NO YES TEST SENSOR. DISCONN
ページ14に含まれる内容の要旨
SELECTRONIC™ PROXIMITY TOILET CONCEALED FLUSH VALVE A922267-0070A 1.28 & 1.6 GPF ROUND GROMMET A908171-0021280A MODEL NUMBERS A922290-0070A COVER (1.28 gpf) POWER SUPPLY GROMMET 6065.26X A908171-0021600A 6065.22X COVER (1.6 gpf) M962745-0070A 6067.22X 6067.26X ELECTRICAL BOX ASSEMBLY M962746-0020A 6068.22X 6068.26X MANUAL VALVE M962748-0070A SENSOR MTG. BRACKET A950223-0071600A SENSOR FOR FLUSH M950169-0070A VALVE WITH 1.6 gpf POWER SUPPLY A950223-0071280A SENSOR FOR FLUSH VALVE WITH 1.28 gpf M9