ページ1に含まれる内容の要旨
Installation
Instructions
3475.500
COLONY/COLONY SOFT
Bidet Faucet and Transfer Valve
with Speed Connect™ Drain
Congratulations on purchasing your American
Standard faucet with the Speed Connect drain, a
feature found only on American Standard faucets.
Certified to comply with ANSI A112.18.1
M968677 Rev. 1.1
Speed Connect Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
*Your new American Standard faucet is desig
ページ2に含まれる内容の要旨
POP-UP DRAIN 3 Fig. A. Fig. B. DRAIN Remove CLEAR PLASTIC COVER (1). 1 BODY Remove CARDBOARD SPACER (2) from under DRAIN POP-UP (3). 3 Tighten TAILPIECE (4) on DRAIN BODY before 7 installing DRAIN BODY. Fig. B. 2 REMOVE FLANGE 4 Fig. A. Fig. B. 1 Thread FLANGE (1) counter-clockwise and remove FLANGE (1) and FOAM GASKET (2) from drain body. Fig. A. Thread LOCKNUT (3) clock-wise to bottom of drain body. Push GASKET (4) down against LOCKNUT (3). Fig. B. 4 2 3 INSTALL DRAIN FROM TIGHTEN LOCKNUT 5 6
ページ3に含まれる内容の要旨
ATTACH CABLE 8 Fig. A. Fig. B. Fig. C. CONNECTOR DOWN POP-UP KNOB (1) must be fully down. Fig. A. 1 Thread CABLE CONNECTOR (1) clockwise onto DRAIN BODY CONNECTION (2) and hand tighten. Fig. B. Your new POP-UP DRAIN installation is now complete. 2 Fig. C. 1-1/4” O.D. Note: Tailpeice on pop-up drain is 1-1/4” O.D. Fig. C. CHECK OPERATION OF POP-UP 9 5 Operate LIFT KNOB (1) to verify that STOPPER (2) opens and closes. 4 1 3 Note: If STOPPER (2) does not open and close properly then refer to the “
ページ4に含まれる内容の要旨
INSTALL HANDLES 4 11 LEVER HANDLE Turn HANDLE STEM (1) to "OFF" position. Place the HANDLE ADAPTER (2) on the HANDLE STEM (1). Install the 5 ADAPTER SCREW (3) and tighten securely. Position LEVER HANDLE (4) and place on ADAPTER (2). Install the 3 HANDLE SCREW (5) and tighten securely. 2 1 TEST INSTALLED FITTING OUTLINE OF BIDET 12 1 With HANDLES (1) in OFF position, turn on WATER 3 SUPPLIES (2) and check all connections for leaks. Operate both HANDLES (1) to flush water 1 lines thoroughly. Rotate
ページ5に含まれる内容の要旨
Speed Connect™ Drain Troubleshooting Guide If sink does not hold water even though Stopper is in the “down” position: • Follow CABLE ADJUSTMENT PROCEDURE. If Stopper does not raise up fully or sink drains too slowly: • Follow CABLE ADJUSTMENT PROCEDURE. If you need to remove the Stopper: • Follow STOPPER REMOVAL PROCEDURE. If you would like the ability to remove your Stopper simply by lifting it out of the drain: • Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode. C
ページ6に含まれる内容の要旨
STOPPER INSTALLATION PROCEDURE The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be removed) or “Unlock” Mode (Stopper is removable). Locked Mode: Look at the Plastic Loop at the bottom of the Stopper and notice Fig. G. that the Loop is on one side of the Stopper. Fig. G. To install the stopper in “Locked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the LOGO Sink and the American Standard logo is facing front. Rotate Stopper s
ページ7に含まれる内容の要旨
Installation Instructions 3475.301 COLONY/COLONY SOFT Bidet Faucet and Transfer Valve 3475.501 with SpeedConnect™ Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Certified to comply with ANSI A112.18.1 SpeedConnect Drain* M968796 Rev.1.1 • Fewer parts, installs in less time Never needs adjustment Guaranteed to seal properly the first time, every time. *Your new American Standard faucet is desig
ページ8に含まれる内容の要旨
POP-UP DRAIN 3 Fig. A. Fig. B. DRAIN Remove CLEAR PLASTIC COVER (1). 1 BODY Remove CARDBOARD SPACER (2) from under DRAIN POP-UP (3). 3 Tighten TAILPIECE (4) on DRAIN BODY before 7 installing DRAIN BODY. Fig. B. 2 REMOVE FLANGE 4 Fig. A. Fig. B. 1 Thread FLANGE (1) counter-clockwise and remove FLANGE (1) and FOAM GASKET (2) from drain body. Fig. A. Thread LOCKNUT (3) clock-wise to bottom of drain body. Push GASKET (4) down against LOCKNUT (3). Fig. B. 4 2 3 INSTALL DRAIN FROM TIGHTEN LOCKNUT 5 6
ページ9に含まれる内容の要旨
ATTACH CABLE 8 Fig. A. Fig. B. Fig. C. CONNECTOR DOWN POP-UP KNOB (1) must be fully down. Fig. A. 1 Thread CABLE CONNECTOR (1) clockwise onto DRAIN BODY CONNECTION (2) and hand tighten. Fig. B. Your new POP-UP DRAIN installation is now complete. 2 Fig. C. 1-1/4” O.D. Note: Tailpeice on pop-up drain is 1-1/4” O.D. Fig. C. CHECK OPERATION OF POP-UP 9 5 Operate LIFT KNOB (1) to verify that STOPPER (2) 4 opens and closes. 3 1 Note: If STOPPER (2) does not open and close properly 1 then refer to the
ページ10に含まれる内容の要旨
INSTALL HANDLES (Lever) INSTALL HANDLES (Acrylic) 11 Turn HANDLE STEM (1) to "OFF" Turn HANDLE STEM (1) to "OFF" position. position. 4 Place the ACRYLIC HANDLE (2) Place the HANDLE ADAPTER (2) 5 on the HANDLE STEM (1). on the HANDLE STEM (1). 3 4 Install the HANDLE SCREW (3) Install the ADAPTER SCREW (3) and tighten securely. and tighten securely. Position 3 LEVER HANDLE (4) and place Push in INDEX BUTTON (4). on ADAPTER (2). 2 2 Install the HANDLE SCREW (5) and tighten securely with hex wrench
ページ11に含まれる内容の要旨
SpeedConnect™ Drain Troubleshooting Guide If sink does not hold water even though Stopper is in the “down” position: Follow CABLE ADJUSTMENT PROCEDURE. If Stopper does not raise up fully or sink drains too slowly: Follow CABLE ADJUSTMENT PROCEDURE. If you need to remove the Stopper: Follow STOPPER REMOVAL PROCEDURE. If you would like the ability to remove your Stopper simply by lifting it out of the drain: Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode. CAB
ページ12に含まれる内容の要旨
STOPPER INSTALLATION PROCEDURE The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be removed) or “Unlock” Mode (Stopper is removable). Locked Mode: Look at the Plastic Loop at the bottom of the Stopper and notice Fig. G. that the Loop is on one side of the Stopper. Fig. G. To install the stopper in “Locked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the LOGO Sink and the American Standard logo is facing front. Rotate Stopper s