ページ1に含まれる内容の要旨
DPCI O-CS Add/Subtract Totalizer (Solid State Inputs)
DPCI O-CC Add/Subtract Totalizer (Contact Inputs)
Ml 663/0693
b- 2.95 ” (74.93mm) -H
-w
f--- 2.677 ” (68mm)
I
I
Recommended
1.299”
7mm)
Panel Cutout
(33mm)
COUNT INPUT A (SUBTRACT); COUNT INPUT B (ADD)
POWER
(TERMINALS 2&3)
Internal battery: 3V, lithium
DPCl&CS
Life expectancy: 5 years +
Inputs A& B require a voltage source, such as a current sourcing
Replacement Part: DPClO-BAT
sensor or a current sinking sensor used with the provided pull u
ページ2に含まれる内容の要旨
PROGRAM MODE INTRODUCTION NOTE: To enter the program mode, you must connect a Your OMEGA DPCl 0-CS or DPCIO-CC is a counter with an jumper between terminals 1 and 5 (see page 4). To leave eight-digit LCD display. A programmable scaler and decimal the program mode, disconnect the jumper. point allow for display in any engineering unit. Screens FRONT VIEW Plastic There are four program-mode screens in the DPCl 0-CS and front panel - DPClO-CC. Upon entering the setup mode, thecounterwill sealed t
ページ3に含まれる内容の要旨
COUNT SCALER The far right digit will be flashing. Press the m key until reaching the desired digit value. Calculating the Count Scale Factor Note: Pressing and holding the m key will cause the The count scale factor is used to convert the incoming count numbers to autoscroll. pulses to the desired unit of measure to be displayed (feet, gallons, etc.) or to correct for a known amount of error (wheel Next press them key to move the flashing digit one place wear, viscosity, etc.). This scaler has
ページ4に含まれる内容の要旨
Enabling the Front Panel Reset Key WIRING DIAGRAMS SOLID STATE ADD/SUBTRACT INPUT (DPClO-CS) The fourth screen in the program mode allows you to enable CURRENT SOURCING SENSOR or disable the front panel reset key. SOLID STATE ADD/SUBTRACT INPUT (DPClO-CS) CURRENT SINKING SENSOR +6 to +28 VDC m key to choose the option you want. Press the Note: The reset terminal on the rear panel is still active when the front reset button is disabled. , Note: To exit the program mode, disconnect the jumper bet
ページ5に含まれる内容の要旨
_ , ^.._ OTHER OMEGA M IN I COUNTER PRODUCTS REPLACEMENT PARTS DPC 0l - K To ta li ze r DPC O l - BAT Ba tt e ry Quad r a tu r e Ind ica to r Gaske t DPC 0I - QT 46066-210 M oun ti ng C li p DPC I O - RM Ra te m e te r 53300-241 DPC 0l - RT R a t e m e t e rfl o t a li zer M oun ti ng Sc r ew 28772-200 OMEGA wa rrants this unit to be free of defects in materials and workmanship and to give satisfactory service for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one
ページ6に含まれる内容の要旨
OMEGA@ . . . Your Sdurce for Process Measurement and Control TEMPERATURE Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators 8 Ice Point References Recorders, Controllers 8 Process Monitors Infrared Pyrometers PRESSURE/STRAIN FORCE m Transducers & Strain Gauges B Load Cells 8 Pressure Gauges 5 Displacement Transducers m Instrumentation 8 Accessories FLOW/LEVEL B Rotameters, Gas Mass Flowmeters 8 Flow Computers [g Air Velocity In