ページ12に含まれる内容の要旨
k Exponential Display Formats This calculator can display up to 10 digits. Larger values are automatically displayed using exponential notation. In the case of decimal values, you can select between two formats that determine at what point exponential notation is used. •To change the exponential display format, press the F key a number of times until you reach the exponential display format setup screen shown below. Fi x Sc i Nor m 1 2 3 •Press 3. On the format selection screen that app
ページ13に含まれる内容の要旨
•Press the number key ( 1 or 2) that corresponds to the setting you want to use. 1(Dot): Period decimal point, comma separator 2(Comma): Comma decimal point, period separator k Initializing the Calculator • Perform the following key operation when you want to initialize the calculation mode and setup, and clear re- play memory and variables. A B 3(All) = COMP Basic Calculations k Arithmetic Calculations Use the F key to enter the COMP Mode when you want to perform basic calculations. COMP ......
ページ14に含まれる内容の要旨
2 1 13 • Example 1: 3 5 15 00 2 C 3 + 1 C 5 = 13 15. 1 2 11 • Example 2: 3 1 4 4 3 12 3 C 1 C 4 + 00 1 C 2 C 3 = 4 11 12. 2 1 • Example 3: 2 C 4 = 4 2 1 • Example 4: 1.6 2.1 1 C 2 + 1.6 = 2 • Results of calculations that mix fraction and decimal val- ues are always decimal. uDecimal ↔ Fraction Conversion •Use the operation shown below to convert calculation results between decimal values and fraction values. • Note that conversion can take as long
ページ15に含まれる内容の要旨
uMixed Fraction ↔ Improper Fraction Conversion 2 5 • Example: 1 ↔ 3 3 00 1 C 2 C 3 = 1 2 3. 00 A B 5 3. 00 A B 1 2 3. •You can use the display setup (Disp) screen to specify the display format when a fraction calculation result is greater than one. •To change the fraction display format, press the q key a number of times until you reach the setup screen shown below. Disp 1 •Display the selection screen. 1 •Press the number key ( 1 or 2) that corresponds to the setting you want to use. b 1
ページ16に含まれる内容の要旨
• Example 5: To discount the sum of 168, 98, and 734 by 20% (800) 168 + 98 + 734 = g A j 1 p 1 - 20 A v , * *As shown here, if you want to use the current Answer Memory value in a mark up or discount calculation, you need to assign the Answer Memory value into a variable and then use the variable in the mark up/discount calculation. This is because the calculation performed when v is pressed stores a result to Answer Memory before the , key is pressed. • Example 6: If 300 grams are added to a te
ページ17に含まれる内容の要旨
k FIX, SCI, RND •To change the settings for the number of decimal places, the number of significant digits, or the exponential dis- play format, press the F key a number of times until you reach the setup screen shown below. Fi x Sc i Nor m 1 2 3 •Press the number key ( 1, 2, or 3) that corresponds to the setup item you want to change. 1 (Fix): Number of decimal places 2 (Sci): Number of significant digits 3 (Norm): Exponential display format • Example 1: 200 7 14 00 200 \ 7 - 14
ページ18に含まれる内容の要旨
COMP Memory Calculations Use the F key to enter the COMP Mode when you want to perform a calculation using memory. COMP .............................................................F 1 k Answer Memory •Whenever you press = after inputting values or an ex- pression, the calculated result automatically updates Answer Memory contents by storing the result. •In addition to =, Answer Memory contents are also up- dated with result whenever you press A v, |, A {, or A j followed by a letter (A through
ページ19に含まれる内容の要旨
• Example: 23 9 32 23 + 9 A j 3 (M+) 53 6 47 53 , 6 | ) 45 2 90 45 - 2 A { (Total) –11 0 3 (M+) k Variables • There are nine variables (A through F, M, X and Y), which can be used to store data, constants, results, and other values. •Use the following operation to delete data assigned to a particular variable: 0 A j 1. This operation de- letes the data assigned to variable A. • Perform the following key operation when you want to clear the values assigned to all of the variables. A
ページ20に含まれる内容の要旨
k Trigonometric/Inverse Trigonometric Functions •To change the default angle unit (degrees, radians, grads), press the F key a number of times until you reach the angle unit setup screen shown below. Deg Rad Gra 1 2 3 •Press the number key (1, 2, or 3) that corresponds to the angle unit you want to use. π (90° = radians = 100 grads) 2 • Example 1: sin 63°5241 0.897859012 ..... q 1 (Deg) S 63 I 52 I 41 I = π • Example 2: cos ( rad) 0.5 3 ..... q 2 (Rad) W R A x \ 3 T = 2
ページ1に含まれる内容の要旨
fx-82MS
fx-83MS
fx-85MS
fx-270MS
fx-300MS
fx-350MS
User's Guide
http://world.casio.com/edu/
E
ページ2に含まれる内容の要旨
CASIO ELECTRONICS CO., LTD. Unit 6, 1000 North Circular Road, London NW2 7JD, U.K.
ページ3に含まれる内容の要旨
Removing and Replacing the Calculator’s Cover • Before starting .....1 Holding the cover as shown in the illustration, slide the unit out of the cover. •After you are finished .....2 Holding the cover as shown in the illustration, slide the unit out of the cover. •Always slide the keyboard end of the unit into the cover first. Never slide the display end of the unit into the cover. .....1 .....2 E-1
ページ4に含まれる内容の要旨
Safety Precautions Be sure to read the following safety precautions before using this calculator. Keep this manual handy for later ref- erence. Caution This symbol is used to indicate information that can result in personal injury or material damage if ignored. Batteries •After removing the battery from the calculator, put it in a safe place where it will not get into the hands of small children and accidentally swallowed. • Keep batteries out of the reach of small children. If accidentally swal
ページ5に含まれる内容の要旨
• The contents of this manual are subject to change with- out notice. •In no event shall CASIO Computer Co., Ltd. be liable to anyone for special, collateral, incidental, or consequential damages in connection with or arising out of the purchase or use of these materials. Moreover, CASIO Computer Co., Ltd. shall not be liable for any claim of any kind whatsoever against the use of these materials by any other party. Handling Precautions • Be sure to press the 5 key before using the calcu- lator
ページ6に含まれる内容の要旨
• Never drop the calculator or otherwise subject it to strong impact. • Never twist or bend the calculator. Avoid carrying the calculator in the pocket of your trou- sers or other tight-fitting clothing where it might be sub- jected to twisting or bending. • Never try to take the calculator apart. • Never press the keys of the calculator with a ball- point pen or other pointed object. • Use a soft, dry cloth to clean the exterior of the cal- culator. If the calculator becomes very dirty, wipe it
ページ7に含まれる内容の要旨
Contents Removing and Replacing the Calculator’s Cover .................................. 1 Safety Precautions .................................. 2 Handling Precautions ............................. 3 Two-line Display ...................................... 7 Before getting started... .......................... 7 kModes .................................................................... 7 kInput Capacity ........................................................ 8 kMaking Corrections During Input
ページ8に含まれる内容の要旨
kCommon and Natural Logarithms/ Antilogarithms ...................................................... 19 kSquare Roots, Cube Roots, Roots, Squares, Cubes, Reciprocals, Factorials, Random Numbers, π, and Permutation/Combination ......................... 19 kAngle Unit Conversion ......................................... 20 kCoordinate Conversion (Pol (x, y), Rec (r, )) ..... 20 kEngineering Notation Calculations ....................... 21 Statistical Calculations ......................... 21 Sta
ページ9に含まれる内容の要旨
Two-line Display The two-line display makes it possible to view both the calculation formula and its result at the same time. • The upper line shows the calculation formula. • The lower line shows the result. A separator symbol is displayed every three digits when the integer part of the mantissa has more than three dig- its. Before getting started... k Modes Before starting a calculation, you must first enter the cor- rect mode as indicated in the table below. To perform this type of Perform th
ページ10に含まれる内容の要旨
Note! •To return the calculation mode and setup to the initial defaults shown below, press A B 2(Mode) =. Calculation Mode: COMP Angle Unit: Deg Exponential Display Format: Norm 1 b Fraction Display Format: a /c Decimal Point Character: Dot • Mode indicators appear in the upper part of the display. •Be sure to check the current calculation mode (SD, REG, COMP) and angle unit setting (Deg, Rad, Gra) before beginning a calculation. k Input Capacity • The memory area used for calculation input can
ページ11に含まれる内容の要旨
k Replay Function • Every time you perform a calculation, the replay function stores the calculation formula and its result in replay memory. Pressing the [ key displays the formula and result of the calculation you last performed. Pressing [ again back steps sequentially (new-to-old) through past calculations. •Pressing the e or r key while a replay memory cal- culation is on the display changes to the editing screen. •Pressing the e or r key immediately after you finish a calculation displays