ページ1に含まれる内容の要旨
Residential • Gas-fired • Hot Water Boilers
User’s Information Manual
™
VICTORY II GAS BOILERS – VHS MODELS
VHS Models with Intermittent Pilot System – Spark Ignition
FOR YOUR SAFETY:
• Before operating this boiler, READ this manual.
• DO NOT attempt to install, service or repair this boiler yourself. There are no user serviceable parts.
Contact a qualified service agency if your boiler needs repair or maintenance. Ask your gas supplier
for a list of qualified service agencies.
• A qualified s
ページ2に含まれる内容の要旨
VICTORY II VHS MODELS Pressure relief valve Blower assembly Adapter and condensation drain Air flow proving switch Ignition control Aquastat Inducer relay Junction box Circulator Gas valve Condensation trap Figure 1. Location and identification of parts WELCOME TO OUR VALUED CUSTOMER DO NOT use this boiler if any part has been You are now the owner of a Slant/Fin Victory II underwater. Immediately call a qualified serv- gas-fired boiler, another quality heating product ice technician to inspect
ページ3に含まれる内容の要旨
VICTORY II VHS MODELS INSPECTION Your boiler and heating system will last an indefinitely long time at full efficiency, if it is inspected regularly and is kept in good repair and adjustment.You, the user, should make regular inspections, and report any problems to your service agency. At regular intervals, you should have that agency inspect the system, clean the boiler and make repair adjustments as necessary. What you and the service agency should do is listed below. Contact your gas supplie
ページ4に含まれる内容の要旨
VICTORY II VHS MODELS 2. Condensation drain trap inspection Check condensation drain trap to be full of water. Check for deterioration of the tubing. Check that trap is not plugged. DO NOT operate the boiler without filling the trap with water to prevent flue gas discharge into space. The drain should extend to a floor drain or to a contain- er which may require emptying periodically. 3. Piping inspection Look at all water piping. There should be no leaks or signs of leaks at any pipe joints or
ページ5に含まれる内容の要旨
VICTORY II VHS MODELS Figure 6. Figure 7. 3. Condensation drain trap inspection A. High limit control test See page 4 for instruction. Set thermostat high enough for water tempera- 4. Piping inspection ture to reach high limit control setting of Check the following: Aquastat. When this temperature is reached, the A. Water piping and accessories for leaks. Slightest high limit switch should open and the main gas leaks should be corrected. valve should close automatically. B. System to be full of
ページ6に含まれる内容の要旨
VICTORY II VHS MODELS C. Adjust main burners and pilot flames. See 2. Remove jacket top. “Installation and Operating Instructions”, for instruc- 3. Remove inducer assembly. tions. 4. Remove flue collector. D. Check input gas rate to the burners. See 5. Use wire brush to clean flue passages. “Installation and Operating Instructions”, for instruc- 6. Replace flue collector and re-seal with tions. furnace cement. E. To prolong the life of inducer motor, lubricate with 7. Replace inducer assembly,
ページ7に含まれる内容の要旨
VICTORY II VHS MODELS C. DO NOT use this appliance if any part has been underwater. Immediately call a qualified service tech- nician to inspect the appliance and to replace any part of the control system and any gas control which has been underwater. Figure 10. To turn off gas to appliance 1. Set thermostat to lowest setting. 2. Turn off all electric power to the appliance if service is to be Figure 9. performed. 3. Turn gas control knob clockwise to “OFF”. DO NOT force. OPERATING INST
ページ8に含まれる内容の要旨
SLANT/FIN CORPORATION, Greenvale, N.Y. 11548 • Phone: (516) 484-2600 FAX: (516) 484-5921 • Canada: Slant/Fin LTD/LTEE, Mississauga, Ontario www.slantfin.com