ページ1に含まれる内容の要旨
Built-In Wall Oven
27” (68.6 cm) models
JKS10, JKP30, JKP35, JKP55, JKP70, JKP75,
Installation
PK916, PK956, ZEK938, ZEK958
30” (76.2 cm) models
Instructions
JTP30, JTP35, JTP55, JTP70, JTP75, PT916,
PT920, PT956, PT960, ZET938, ZET958
If you have questions, call 1.800.GE.CARES or visit our website at:
ge.com
• Proper installation is the responsibility
Before You Begin
of the installer and product failure due
Read these instructions carefully and completely.
to improper installation is NOT cover
ページ2に含まれる内容の要旨
Installation Instructions IMPORTANT SAFETY INSTRUCTIONS For Your Safety Electrical • Be sure your oven is installed properly by Requirements cont. a qualified installer or service technician. • Be sure the oven is securely installed in a Rating plate is located on oven side trim, side front frame or lower front frame. cabinet that is firmly attached to the house structure. Weight on the oven door could cause the oven to tip and result in injury. Never allow anyone to climb, sit, stand or Rating
ページ3に含まれる内容の要旨
EASY INSTALLATION OF YOUR NEW 30" WALL OVEN Before you begin-Read these instructions complet Before you begin-Read these instructions complet Before you begin-Read these instructions complet Before you begin-Read these instructions complet Before you begin-Read these instructions complet Before you begin-Read these instructions complet Before you begin-Read these instructions complet Before you begin-Read these instructions complet Before you begin-Read these instructions complet Before you beg
ページ4に含まれる内容の要旨
Installation Instructions A Cutout for 27″ (68.6 cm) Single Built-In Ovens only For JKS10, JKP30, JKP70, PK916, ZEK938 models only. Cabinet Width 27” (68.6 cm) 5” (12.7 cm) Max. from the left or right Recommended side Cabinet Junction Box Cutout Location Width Location 27” (68.6 cm) from Floor 32 1/2” (82.6 cm) Cutout Depth 23 1/2” (59.7 cm) Min. Cutout Width 25” (63.5 cm) Min. Cutout Width 25” (63.5 cm) Min. Allow 1” (2.5 cm) 25 1/4” (64.1 cm) for overlap of Max. 25 1/4” (64.1 cm) Max. oven ove
ページ5に含まれる内容の要旨
Installation Instructions A Cutout for 27″ (68.6 cm) Double Built-In Ovens only For JKP35, JKP55, JKP75, PK956, ZEK958 models only. 5” (12.7 cm) Cabinet Width 27” (68.6 cm) Max. from the left or Cabinet right Recommended Width side Cutout Location 27” (68.6 cm) from Floor 13 1/4” (33.7 cm) Junction Box Cutout Location Width 25” (63.5 cm) Min. Cutout Depth 23 5/8” (60 cm) Min. 25 1/4” (64.1 cm) Max. Allow 1” (2.5 cm) Cutout Width 25” (63.5 cm) Min. for overlap of oven over side 25 1/4” (64.1 cm)
ページ6に含まれる内容の要旨
Installation Instructions A Cutout for 27″ (68.6 cm) Single Built-In Ovens only Under Counter For JKS10, JKP30, JKP70, PK916, ZEK938 models only. Gas or electric cooktops may be installed over this oven. See cooktop installation instructions for cutout size. See label on top of oven for approved cooktop models. 240V / 208V Junction Box 5” Location (12.7 cm) Gas and electrical connections Max. from the 25” (63.5 cm) for gas cooktop must be located left or right in an adjacent accessible side loca
ページ7に含まれる内容の要旨
Cabinetry A Cutout for 27″ (68.6 cm) Single or Double Built-In Ovens only – Over a Warming Drawer For JKS10, JKP30, JKP35, JKP55, JKP70, JKP75, PK916, PK956, ZEK938, ZEK958 models only. Single 27″ (68.6 cm) Double 27″ (68.6 cm) Oven Over Oven Over a Warming Drawer a Warming Drawer Anti-Tip Block Against Rear Anti-Tip Block Against Wall Per Rear Wall Per Warming Warming Drawer Requirement Drawer Requirement 2” (5.1 cm) Min. 2” (5.1 cm) NOTE: Install the Min. oven only with specific models listed
ページ8に含まれる内容の要旨
Cabinetry A Cutout for 27″ (68.6 cm) Single Ovens only – Below an Advantium or Microwave Oven or Between an Advantium or Microwave Oven and a Warming Drawer For JKS10, JKP30, JKP70, PK916, ZEK938 models only. Single 27″ (68.6 cm) Oven Single 27″ (68.6 cm) Oven Below an Advantium or Between an Advantium or Microwave Oven Microwave Oven and a Warming Drawer Per Advantium or Per Advantium or Microwave Oven 2” (5.1 cm) Min. 2” (5.1 cm) Min. Microwave Oven Requirement Requirement Note: Install the o
ページ9に含まれる内容の要旨
Installation Instructions A Cutout for 30″ (76.2 cm) Single Built-In Ovens only For JTP30, JTP70, PT916, PT920, ZET938 models only. Cutout Cabinet Width 30” (76.2 cm) 9 1/2” (24.1 cm) Width CUTOUT Junction Box Max. 5" 28 1/2” (72.4 cm) WIDTH Location Recommended 28 1/2" MIN. Min. (junction box 28 5/8" MAX. Cutout Location 28 5/8” (72.7 cm) may be Max. from Floor 32 1/2” (82.6 cm) located in JUNCTION BOX adjacent LOCATION cabinet) Cutout Depth 23 1/2” (59.7 cm) Min. Allow 11/16” (1.75 cm) for ALL
ページ10に含まれる内容の要旨
Installation Instructions A Cutout for 30″ (76.2 cm) Double Built-In Ovens only For JTP35, JTP55, JTP75, PT956, PT960, ZET958 models only. Cutout 9 1/2” Cabinet Width 30” (76.2 cm) Width (24.1 cm) CUTOUT Junction Box 28 1/2” (72.4 cm) Max. WIDTH Location 5" Recommended 28 1/2" MIN. Min. (junction box 28 5/8" MAX. 28 5/8” (72.7 cm) Cutout Location may be Max. located in from Floor 12” (30.5 cm) JUNCTION BOX adjacent LOCATION cabinet) Cutout Depth 23 1/2” (59.7 cm) Min. Cutout Width 28 1/2” (72.4
ページ11に含まれる内容の要旨
Installation Instructions A Cutout for 30″ (76.2 cm) Single Built-In Ovens only Under Counter For JTP30, JTP70, PT916, PT920, ZET938 models only. Gas or electric cooktops may be installed over this oven. See cooktop installation instructions for cutout size. See label on 240V / 208V top of oven for approved cooktop models. Junction Box Location (junction box may be in adjacent cabinet) Gas and electrical connections 9 1/2” 25” (63.5 cm) for gas cooktop must be located (24.1 cm) in an adjacent a
ページ12に含まれる内容の要旨
Cabinetry A Cutout for 30″ (76.2 cm) Single or Double Built-In Ovens only – Over a Warming Drawer For JTP30, JTP35, JTP55, JTP70, JTP75, PT916, PT920, PT956, PT960, ZET938, ZET958 models only. Single 30″ (76.2 cm) Double 30″ (76.2 cm) Oven Over a Warming Oven Over a Warming Drawer Drawer Anti-Tip Block Against Anti-Tip Block Rear Wall Per Warming Against Rear Drawer Requirement Wall Per 2” (5.1 cm) Warming Min. Drawer Requirement NOTE: Install the 2” (5.1 cm) oven only with Min. specific models
ページ13に含まれる内容の要旨
Cabinetry A Cutout for 30″ (76.2 cm) Single Ovens only – Below an Advantium or Microwave Oven or Between an Advantium or Microwave Oven and a Warming Drawer For JTP30, JTP70, PT916, PT920, ZET938 models only. Single 30″ (76.2 cm) Oven Single 30″ (76.2 cm) Oven Below an Advantium or Between an Advantium or Microwave Oven Microwave Oven and a Warming Drawer Per Advantium or Per Advantium or 2” (5.1 cm) Min. Microwave Oven Microwave Oven 2” (5.1 cm) Min. Requirement Requirement Note: Install the
ページ14に含まれる内容の要旨
Installation Instructions B Electrical Connections Turn off the circuit breaker or remove ATTENTION INSTALLER B1 fuses to the oven branch circuit. All electric wall ovens must be hard wired With the oven supported on a table or B2 (direct wired) into an approved junction platform in front of the cabinet opening, box. A plug and receptacle is NOT permitted connect the flexible conduit to the on these products. electrical junction box as shown below. Position the conduit in such a manner DO NOT sh
ページ15に含まれる内容の要旨
Installation Instructions New Construction and Three-Conductor Branch B3 B4 Four-Conductor Branch Circuit Connection Circuit Connection When connecting to a three-conductor branch circuit, if local codes permit: • When installing in new construction, or a. Connect the bare oven ground conductor • When installing in a mobile home, or with the crimped neutral (white) lead to • When installing in a recreational vehicle, or the branch circuit neutral (white or gray in color), using a wire nut. • Whe
ページ16に含まれる内容の要旨
Installation Instructions C Securing the Oven in the Opening Sliding the Oven Into the Drilling the Pilot Holes and C1 C2 Opening Mounting the Oven a. Loop (do not tie) a 36” (91 cm) string around the conduit before the oven is slid NOTE: Before drilling the pilot holes, into place. This will keep the conduit from make sure the oven is pushed as far falling behind the oven. back into the opening as it will go and centered. a. Drill through the mounting holes (top and bottom) of the side trim, fo
ページ17に含まれる内容の要旨
Installation Instructions Installing the Metal Preparing for the Bottom C4 C3 Bottom Trim Trim Installation a. Place the bottom metal trim centered over a. With oven installed, take the bottom trim the pre-drilled mounting holes. Tape the and center it on the bottom front edge of edges of the trim down to maintain the the cabinet opening. alignment. For 27″ (68.6 cm) b. Using the trim models with Lower as a template, Trim in Position, b. Using two trim screws provided, secure Mark (2) Mounting m
ページ18に含まれる内容の要旨
Installation Instructions D Replacing the Oven Door Open the oven door as far as it D3 NOTE: The oven door is heavy. You will open. may need help lifting the door high enough to slide it into the hinge slots. Push the hinge locks up against the D4 Do not lift the door by the handle. front frame of the oven cavity, to the locked position. Hinge in Lift the oven door by Locked Position D1 placing one hand on each side. The door is heavy, so you may need help. Do not lift the door Notch of Hinge by
ページ19に含まれる内容の要旨
Installation Instructions Pre-Test Checklist Remove all protective film, if present, Check that the bottom trim is installed and any stickers. properly (see page 17). Check to be sure that all wiring is Check to be sure the mounting screws secure and not pinched or in contact are installed and flush with the side trim with moving parts. (see page 16). Operation Checklist Remove all items from the inside NOTE TO ELECTRICIAN: The power of the oven. leads supplied with this appliance are UL recogni
ページ20に含まれる内容の要旨
Notes 20