ページ1に含まれる内容の要旨
CATALOG NO: 2100.51-J
USER'S INFORMATION MANUAL
Effective: 06-15-00
GAS FIRED RESIDENTIAL
Replaces: 11-01-99
HEATING BOILERS
MODELS H- 0030B, 0042B, 0066B, 0090B, 0135B, 0180B
WARNING: If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
- Do not store or use gasoline or other flammable vapors and liquids or other
combustible materials in the vicinity of this or any other appliance. To do so ma
ページ2に含まれる内容の要旨
don't try to repair it, call a qualified service technician. service technician or gas supplier. Force or attempted repair may result in a fire or *If the pilot does not stay lit after several tries, move explosion. the gas control lever to "OFF" and call your service D. Do not use this boiler if any part has been under technician or gas supplier. water. Immediately call a qualified service technician 9. Stand to the side of the heater and move the gas to inspect the boiler and to replace an
ページ3に含まれる内容の要旨
FOR INTERMITTENT IGNITION (IID) WITH is to be performed. HONEYWELL OR ROBERTSHAW GAS VALVE 3. For Honeywell Valve: (For All Models) Turn gas control knob clockwise to "Off". Make sure knob rest against stop. For Robertshaw Valve: 1. STOP! Read the safety information above. 2. Set the thermostat to the lowest setting. Push in and move gas control lever to "Off" 3. Turn off all electric power to the appliance. position. 4. This boiler is equipped with an ignition device which automatically
ページ4に含まれる内容の要旨
1. Burner Inspection. 3. Circulator (Water Pump) Inspection. Clean the main burners and air louvers of dust, lint The circulator is permanently lubricated and thus, and debris. With burner in operation, make a visual will not require any lubrication. Inspect for evidence of check of the burner flame and the pilot flame (when water leakage. This should be corrected to prevent any equipped). Yellow flames indicate some restriction of possible damage to electrical components of t