ページ1に含まれる内容の要旨
CompatiView 5.4
Reference Guide
Compatible Systems Corporation
4730 Walnut Street
Suite 102
Boulder, Colorado 80301
303-444-9532
800-356-0283
http://www.compatible.com
ページ2に含まれる内容の要旨
CompatiView Reference Guide, Version 5.4 Copyright © 1999, Compatible Systems Corporation All rights reserved. CompatiView, RISC Router, MicroRouter, IntraPort and IntraGuard are trademarks of Compatible Systems Corporation. Other trademarks are the property of their respective holders. Part number: A00-1087
ページ3に含まれる内容の要旨
Table of Contents iii Chapter 1 - Installation and Overview 1 TENTS COMPATIVIEW QUICKSTART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 ABOUT THIS MANUAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 COMPATIVIEW INSTALLATION NOTES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 COMPATIVIEW’S MENUS AND MAIN WINDOWS . . . . . . . . . . . . . . . . . . . . . . . . . 3 MOVING AND CUSTOMIZING THE W
ページ4に含まれる内容の要旨
iv Table of Contents Chapter 6 - VPN Ports and LAN-to-LAN Tunnels 97 ADD VPN PORT DIALOG BOX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 TUNNEL PARTNER: VPN CONFIGURATION DIALOG BOX. . . . . . . . . . . . . . . . . . 98 IKE KEY MANAGEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 MANUAL KEY MANAGEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 INTEROPERABILITY SETTINGS DIALOG BOX. .
ページ5に含まれる内容の要旨
Table of Contents v Chapter 11 - TCP/IP Filtering 183 MAIN TCP/IP FILTERING DIALOG BOX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183 TCP/IP FILTER EDITOR WINDOW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184 TCP/IP ROUTE FILTER RULES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185 TCP/IP PACKET FILTER RULES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188 TCP/IP PACKET FILTERING: ETHERNET DIALOG
ページ6に含まれる内容の要旨
vi Table of Contents SECURID CONFIGURATION DIALOG BOX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239 NAT CONFIGURATION DIALOG BOX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241 NAT RANGE DIALOG BOX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244 NAT MAPPING DIALOG BOX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245 LOGGING CONFIGURATION DIALOG BOX . . . . . . . . . . . . . . . . . . . . . . .
ページ7に含まれる内容の要旨
Chapter 1 - Installation and Overview 1 Chapter 1 - Installation and Overview CompatiView Quickstart Follow the instructions in the Installation Guide for your internetworking device to connect it to your network. Install CompatiView by running the install program included on the CD-ROM which was included with your Compatible Systems device. Run CompatiView. Select a network transport protocol using the Database menu’s Options dialog box. Add your device to CompatiView’s device vie
ページ8に含まれる内容の要旨
2 Chapter 1 - Installation and Overview About this Manual This manual documents CompatiView v5.3, which can be used to configure and manage all Compatible Systems products except the MicroRouter 900i and 1000R and the RISC Router 3000E. CompatiView v4.8x may be used to configure those devices. CompatiView v4.8x is available in the Network Management\Compati- View\Windows directory on the CD-ROM that was included with your ship- ping package and in the Software Downloads section of our Web sit
ページ9に含まれる内容の要旨
Chapter 1 - Installation and Overview 3 default of Ethernet A/0 on all devices). After setting the device’s IP address, be sure to change the workstation’s configuration back to its original settings. To use IPX, which will allow you to contact the device without setting any parameters over the device’s Console port, you can either set the appropriate radio button in the Database menu’s Options dialog box or click on the IP/IPX box at the bottom of the main CompatiView screen. (The status ba
ページ10に含まれる内容の要旨
4 Chapter 1 - Installation and Overview The Help menu, which provides standard help functions. Note: Some of the menu items will be grayed out unless you are currently logged into a device. Where applicable, menu selections are put into effect for the current device. This is the device which is currently highlighted in the Device View and is shown in the title of the CompatiView screen. The Device View and the Main Window The Device View The
ページ11に含まれる内容の要旨
Chapter 1 - Installation and Overview 5 If the device is a multislot product such as a VSR or IntraPort Enterprise, both the slot number and the interface number are shown, separated by a colon (e.g., Ethernet 0:0 indicates Slot 0, Ethernet 0, while Ethernet 1:0 indicates Slot 1, Ethernet 0). Administrative information will also be included if it has been set using the Item Properties option under the Database Menu. The list of configuration items associated with each device is an edit a
ページ12に含まれる内容の要旨
6 Chapter 1 - Installation and Overview The File Menu The File menu provides options which allow you to create and manage configurations in CompatiView’s Device View. New Config This option loads default parameters for a particular type of device in the Device View. You will first be asked to select a device type from a list. This option may be useful to preconfigure a device or to use as a base configura- tion for multiple devices. You can edit and view the parameter information by doub
ページ13に含まれる内容の要旨
Chapter 1 - Installation and Overview 7 Download Config to Device Dialog Box Save / Restart Options The settings in this dialog box are specific for this device. For global Save/Restart settings use the Database menu, select options, and choose the Save/Restart tab. To change the Save/Restart mode for a particular device, modify the “Device Properties” for that device. Save config and restart device. This parameter will save an edited configuration to the device’s Flash ROM and restart the
ページ14に含まれる内容の要旨
8 Chapter 1 - Installation and Overview current operations without restarting the device. This is the equivalent of issuing the apply command and then the write command in the command line. While the download is taking place, arrows will move in a circular motion around the device icon in the Device View. To display the amount of time left for the download, click on the + sign next to the device icon. Caution: Turning off a device in the middle of a download may cause it to lose its ope
ページ15に含まれる内容の要旨
Chapter 1 - Installation and Overview 9 Delete opens a confirmation prompt to delete the path. You must have a fire- wall path selected to enable the Delete option. View This menu item brings up the Local Config View tab in the Output Window, which displays the configuration text file for the current device. Print This menu item prints the configuration text file for the current device. Recent File This menu item holds a list of files that have recently been saved. > Exit Exiting takes you
ページ16に含まれる内容の要旨
10 Chapter 1 - Installation and Overview Options This menu item brings up a dialog box which lets you set a variety of options having to do with CompatiView’s operation. Database Options Dialog Box General Tab IPX Transport - IP Transport. This set of radio buttons determines whether CompatiView for Windows will use IPX or IP as a transport. Load IPX upon startup. CompatiView runs IPX behind the scenes to generate IPX tables. I f you do not have IPX on your system, you may want to leave
ページ17に含まれる内容の要旨
Chapter 1 - Installation and Overview 11 be loaded to the file on disk. If left unchecked, you will be prompted each time the config files are changed and not loaded to disk. Hide Data in Secure fields. This checkbox will not show passwords in display dialogs or edit boxes, or the text configuration of the current device in Local Config View at the bottom of the screen. If this box is not checked, passwords will be displayed in the clear. Cascade new windows as they are opened. This chec
ページ18に含まれる内容の要旨
12 Chapter 1 - Installation and Overview Save config, but don’t restart device. This parameter will save an edited configuration without restarting the device. The changes will not be applied until the device is restarted. This is the equivalent of the command line’s write command. Don’t save config, but use new config immediately. This parameter will apply an edited (but not saved) configuration to the device’s current operations. If a restart occurs, changes will be lost. This is the
ページ19に含まれる内容の要旨
Chapter 1 - Installation and Overview 13 The Control menu lets you update the software contained in the Flash ROM of a device. Download Software When new features are added to the operating software for a particular type of device, you may wish to update a device with the new version. When you are using IPX transport protocols and select this option, a window listing all eligible devices will appear. You will first be asked to select one or more devices (which must all be of the same type).
ページ20に含まれる内容の要旨
14 Chapter 1 - Installation and Overview The Output Window The CompatiView Output Window There is an Output Window at the bottom of the Device View which lets you quickly check the current status of the selected configuration parameter or review the device configuration. The tabs show different types of parameter values. In some cases, these parameters may be different than those stored in the device’s Flash ROM due to auto-configuration. The Output Window is broken up into three tabbed sect