ページ1に含まれる内容の要旨
SAPTF33xx-1xx
SAPTF33xx-1xx in the Network Installation
CAUTION: Wear a grounding device and observe electrostatic discharge
Standard Configuration
precautions when setting the jumpers. Failure to observe this caution could
One Unit A device (SAPTF33xx-100) and one Unit B device (SAPTF33xx-110)
result in damage to, and subsequent failure of, the media converter.
are required for the standard configuration. The Unit A device is connected to
Setting the Jumpers
the Central Office (CO) while th
ページ2に含まれる内容の要旨
SAPTF33xx-1xx Installation -- Continued Installation -- Continued Grounding the Media Converter Installing the Cable -- Standard Configuration The SAPTF33xx-1xx single-slot chassis comes equipped with grounding lugs NOTE: Unit B MUST be configured for Standard Configuration (see page 4). located on the back panel. They require a grounding conductor wire terminated with a two-hole, compression-type, grounding connector. The Fiber grounding wire -- which must be a copper conductor -- is not incl
ページ3に含まれる内容の要旨
SAPTF33xx-1xx Installation -- Continued Operation Installing the Cable -- Automatic Ring-Down Configuration Power the Media Converter NOTE: Both Unit B’s MUST be configured for Automatic Ring-Down (see page 4). NOTE: The external power supply provided with this product is UL listed by the power supply’s manufacturer. Fiber AC 1. Locate or build fiber cable with male, two-stranded TX to RX connectors 1. Install the barrel connector of the AC power cord to the external power installed at both e
ページ4に含まれる内容の要旨
SAPTF33xx-1xx Cable Specifications Operation - Continued The physical characteristics must meet or exceed FCC part 68 specifications. Loop-Start Operation Copper Cable -- Category 1 Loop-Start Service -- commonly known as “Plain Old Telephone Service” Either shielded (STP) or unshielded (UTP) twisted-pair is acceptable. (POTS) -- is the primary analog signaling method used between telephone Gauge: 24 to 22 AWG switches such as the Central Office (CO) and a telephone device. Loop-Start Maxim
ページ5に含まれる内容の要旨
SAPTF33xx-1xx RJ-11C Connector Specification Troubleshooting Unit A (Telephone Emulation) 1. Is the PWR (power) LED illuminated? Connector: RJ-11C NO Impedance: 600 Is the power adapter the proper type of voltage and cycle frequency REN: 0.4 B for the AC outlet? (See “Power Supply” on page 12.) Loop Current: 10 to 100 mA Is the power adapter properly installed in the media converter and in Insertion Loss: 0.0 ± 1.0 dB at 1000 Hz the outlet? (When both ports are terminated at 600 .) Doe