ページ1に含まれる内容の要旨
Room Air Conditioner
OWNER'S MANUAL
Models :
LG-BKE 4450 D - LG-BKE 5455 D
LG-BKE 4500 D - LG-BKE 5505 D
LG-BKE 4600 D - LG-BKE 5605 D
LG-BKE 4700 D - LG-BKE 4800 D
• Please read carefully and thoroughly this
manual before operating this unit.
• Contact the authorized SVC man for repair or
maintenance of this unit.
• Contact the installer for installation of this unit.
• The appliance is not intended for use by young
children or infirm persons without supervision.
• Young children should be supe
ページ2に含まれる内容の要旨
Safety precautions Safety Precautions To prevent injury to the user or other people and property damage, the Warning ................................2 following instructions must be followed. Caution .................................3 Incorrect operation due to ignoring of instruction will cause harm or damage, the seriousness is classified by the following indications. Operating Instructions WARNING WARNING Preparation before operation ..4 This symbol indicates the possibility of death or ser
ページ3に含まれる内容の要旨
Safety Precautions Operating Instructions Care and Maintenance Troubleshooting Tips CAUTION • Contact the authorized Service technician for repair or maintenance of this unit. • Contact the installer for installation of this unit. • The air conditioner is not intended for use by young children or infirm persons without supervision. • Young children should be supervised to ensure that they do not play with the air conditioner. CAUTION CAUTION When the air filter is to be Do not clean the air Vent
ページ4に含まれる内容の要旨
Preparation before operation How to Insert the Batteries Remove the battery cover by pulling it according to the arrow direction. Insert new batteries making sure that the (+) and (-) of battery are installed correctly. Reattach the cover by sliding it back into position. NOTES: • Use 2 AAA(1.5volt) batteries. Do not use rechargeable batteries. Storage and Tips For Using the Remote Control •Theremotecontrolmaybestoredmountedona • To operate the room air conditioner, aim the wall. remote control
ページ5に含まれる内容の要旨
Safety Precautions Operating Instructions Care and Maintenance Troubleshooting Tips About the remote control on the system Features of the Remote Control OPERATION DISPLAY Remote Controller 1 Displays the operation conditions. Signal transmitter AIRFLOW DIRECTION START/STOP 2 Transmits the signals to the room air BUTTON Used to stop or start louver movement and conditioner. set the desired up/down airflow direction. OPERATION MODE SELECTION 3 BUTTON Used to select the operation mode. TEMP. OFF T
ページ6に含まれる内容の要旨
Operation Mode Selection button Features of the Remote Control (1) OPERATION MODE Cooling Operation Cooling Operation Healthy Dehumidifacation Operation Healthy Dehumidifacation Operation Heating Operation (Cooling Model) (Heat pump Model) (2) OPERATION PROCEDURE Start/Stop Button 1st TEMP. OFF TIME hr. Operation Mode Selection 2 2nd Button 4 Room Temperature 1 3rd Setting Button 3 Indoor Fan Speed 4th Selection Button 6 Troubleshooting Tips Care and Maintenance Operating Instructions Safety Pre
ページ7に含まれる内容の要旨
Safety Precautions Operating Instructions Care and Maintenance Troubleshooting Tips Cooling Operation Press the Start/Stop Button. 1 Select Cooling Operation. 2 Press the Operation Mode Selection Button. Each time the button is pressed, the operation mode is shifted in the arrow direction. TEMP. TEMP. TEMP. TEMP. OFF OFF OFF TIME hr. TIME hr. TIME hr. OFF TIME hr. Cooling Healthy Heating Dehumidification (Heat pump model only) TEMP. TEMP. OFF OFF TIME hr. TIME hr. Healthy Cooling Dehumidificatio
ページ8に含まれる内容の要旨
Healthy Dehumidification Operation Mode This mode dehumidifies without overcooling. Press the Start/Stop Button. 1 Select Healthy Dehumidification Operation. 2 OFF TIME hr. Press the operation Mode Selection Button. Each time the button is pressed, the operation mode is shifted in the arrow direction. TEMP. TEMP. TEMP. OFF TIME hr. OFF TIME hr. OFF TIME hr. Cooling Healthy Heating Dehumidification (Heat pump model only) TEMP. TEMP. OFF TIME hr. OFF TIME hr. Healthy Cooling Dehumidification You c
ページ9に含まれる内容の要旨
Safety Precautions Operating Instructions Care and Maintenance Troubleshooting Tips Heating Operation(Heat pump model only) Press the Start/Stop button. 1 The unit will respond with a beep. To select Heating Operation, press the Operation Mode 2 Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow. TEMP. OFF TIME TIME h hr r.. TEMP. TEMP. TEMP. OFF TIME hr. OFF TIME hr. OFF TIME hr. Cooling Healthy Heating Dehumidification (Heat pump mode
ページ10に含まれる内容の要旨
Jet Cool Operation Press the Start/Stop button. 1 The unit will respond with a beep. Press the Jet Cool button to operate the 2 speed cooling mode and the unit will TEMP. operate in super high fan speed on cooling TIME hr. OFF TIME hr. mode for 30 minutes. To cancel the Jet Cool mode, press the Jet Cool button again or the fan speed button or the room temperature 3 setting button and the unit will operate in high fan speed on cooling mode. or or or NOTE: ❏ During the JET COOL function at any mom
ページ11に含まれる内容の要旨
Safety Precautions Operating Instructions Care and Maintenance Troubleshooting Tips Airflow Direction Procedure Airflow Direction Control Press the Start/Stop Button. 1 (Confirm the unit on operation.) The airflow direction can be adjusted as desired by using the remote controller. This is effective when you want to cool yourself directly, such as after taking a bath. Press the Airflow Direction Control 2 Button and the vertical louvers swing up and down automatically. Press again the Airflow Di
ページ12に含まれる内容の要旨
Forced Operation Operation procedures when the remote control can't be used. The operation will be started if the power button is pressed. If you want to stop operation, re-press the button. Power button Open the front panel upward Heat pump Model Cooling Model Room Temp. 24°C 21°C Room Temp. < 24°C Room Temp. < 21°C Operating mode Cooling Cooling Healthy Dehumidification Heating Indoor FAN Speed High High High High Setting Temperature 22°C 22°C 23°C 24°C Test operation During the TEST OPERA
ページ13に含まれる内容の要旨
Safety Precautions Operating Instructions Care and Maintenance Troubleshooting Tips P o G w a d s e o r Care and maintenance of the air conditioner CAUTION: Before performing any maintenance, turn off the main power to the system. Indoor Unit ❏ Never use any of the followings: Grille, Case, and Remote Control • Water hotter than 40°C ❏ Turn the system off before cleaning. To Could cause deformation and/or clean, wipe with a soft, dry cloth. Do not discoloration. use bleach or abrasives. • Volati
ページ14に含まれる内容の要旨
Whentheairconditionerisnotgoingtobeusedforalongtime. When air conditioner is not going to be When the air conditioner is to be used again. used for a long time. Clean the air filter and install it in the indoor Turn off the circuit breaker, and disconnect the plug. unit. (Refer to page 13 for cleaning filters.) CAUTION Turn off the circuit breaker when the air conditioner is not going to be used for a long time. Dirt may collect and may cause a fire. Check that the air inlet and outlet of the Re
ページ15に含まれる内容の要旨
Safety Precautions Operating Instructions Care and Maintenance Troubleshooting Tips Before you call for service... Troubleshooting Tips! Save time and money! ? Check the following points before requesting repairs or service.... If the fault persists, please contact your dealer or service center. Case Explanation See page The air conditioner does not • Have you made a mistake in timer operation? operate. • Has the fuse blown or has the circuit breaker - been tripped? The room has a peculiar • Che