ページ1に含まれる内容の要旨
IPLink™ Model 2603 & 2620
WAN Access Router
Quick Start Guide
Document Number: 03323U7-001 Rev. B Sales Office: +1 (301) 975-1000
Part Number: 07M2620-QS Technical Support: +1 (301) 975-1007
E-mail: support@patton.com
Revised: October 4, 2005
WWW: www.patton.com
ページ2に含まれる内容の要旨
• The IPLink 2603/2620 contains no user serviceable parts. The equip- ment shall be returned to Patton Electronics for repairs, or repaired by qualified service personnel. WARNING • An approved external power supply that incorporates a disconnect device shall be used and positioned within easy reach of the operator. • For AC powered units, the power cable used to connect the power supply shall meet all applicable standards for the country in which it is to be instal
ページ3に含まれる内容の要旨
1.3 Models with internal DC power supply 1. Strip insulation 1/4-inch from the electrical wires that will connect the DC power source to the IPLink. 2. Connect the ground terminal from the power source to the ground terminal on the IPLink. 3. Connect the negative (-) terminal from the power source with to the negative (-) terminal on the IPLink. 4. Connect the positive (+) terminal from the power source with to the positive (+) terminal on the
ページ4に含まれる内容の要旨
RX TX 10/100 Crossover MDI-X Power Ethernet WAN 2.2 Modifying the IP address 1. Display current IP interface settings for the IPLink Ethernet LAN port. fifififi ip list interfaces IP Interfaces: ID | Name | IP Address | DHCP | Transport ---|------|----------------|----------|-------------- 1 | ip1 | 192.168.200.10 | disabled | ---------------------------------------------------- 2. Modify the IP address for the
ページ5に含まれる内容の要旨
You can check the network connection with the ping command. For example, you would ping 10.10.10.5 from your PC. 4.0 Log onto the web management interface You will now access the web management Graphical User Interface (GUI) to configure the IPLink using a stan- dard web browser (such as Internet Explorer or Netscape browser). 1. At your PC, open a web browser and enter the IP address you assigned to the IPLink’s Ethernet LAN port in step 2 of section 2.2 “Modifyin
ページ6に含まれる内容の要旨
Connecting to the RJ-48C WAN port 1. Obtain a twisted-pair cable with an RJ-48C plug connector at each end. 2. Plug one end of the cable into the RJ-48C socket (labeled WAN) on the IPLink Router. 3. Plug the other end of the cable into the T1/E1 device. 4. Repeat steps 1 through 3 to install the remaining WAN cables on a Model 2620 Connecting to the unbalanced 75-ohm TX and RX WAN ports (Model 2603/K and 2620/KK only) 1. Obtain
ページ7に含まれる内容の要旨
B.0 Compliance Information B.1 Radio and TV Interference (FCC Part 15) This equipment generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manufacturer's instructions—may cause interference to radio and television recep- tion. This equipment has been tested and found to comply with the limits for a Class A computing device in accor- dance with the specifications in Subpart B of Part 15 of FCC rules, which are des
ページ8に含まれる内容の要旨
Connection to party line service is subject to state tariffs. Contact the state public utility commission, public ser- vice commission or corporation commission for information. B.4 Industry Canada Notice This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications. This is con- firmed by the registration number. The abbreviation, IC, before the registration number signifies that registra- tion was performed based on a Declaration of Conformity