ページ1に含まれる内容の要旨
THE WALL-MOUNT™ AIR CONDITIONERS (50HZ)
Models W24A to W70A and W24L to W70L
GREEN REFRIGERANT
21,200 Btuh (6.21 KW) – 59,000 Btuh (17.28 KW)
R-410A
Right Side Control Panel 50Hz
The Bard Wall-Mount Air Conditioner is a self contained energy efficient
system, which is designed to offer maximum indoor comfort at a minimal
cost without using valuable indoor floor space or outside ground space.
This unit is the ideal product for versatile applications such as: new
construction, modular offices
ページ2に含まれる内容の要旨
Capacity and Efficiency Ratings W24A1 W36A1 W42A1 W48A1 W60A1 W70A1 MODELS W30A1 W24L1 W36L1 W42L1 W48L1 W60L1 W70L1 C0 ooling Capacity Btuh20 1,20 20 6,00 30 1,20 30 6,00 40 1,50 40 8,50 59,00 C1 ooling Capacity KW 62 .2 74 .6 94 .1 15 0.5 10 2.1 18 4.2 17.2 E0 ER 90 . 90 . 92 . 90 . 90 . 95 . 9. All capacity, efficiency and cost of operation information is based on high speed operation with fresh air cover plate. Cover plate must be ordered separately and is recommended for use to obtain max
ページ3に含まれる内容の要旨
Ventilation System Packages Bard Wall-Mounts are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality requirements. Standard on all units is the barometric fresh air damper. All packages can be ordered built-in at the factory or can be easily field-installed at the time of installation of the Wall-Mount, or can be retrofitted at a later date. BAROMETRIC FRESH AIR DAMPER - BFAD STANDARD The barometric fresh air damper is a standard featu
ページ4に含まれる内容の要旨
Minimum Clearances - Inches (mm) Clearances - Inches (mm) Required to Combustible Materials Required for Service Access and SUPPLY AIR DUCT Adequate Condenser Airflow MODELS 1 1 1 1 1 FIRST 3 FEET (1m) CABINET MODELS LEFT SIDE RIGHT SIDE W0 24A, W24L 0 W24A, W30A, W36A 1) 5 (380) 20 (510 W24L, W36L W) 30A, W36A, W36L .0 25 (6.35 W42A, W48A, W60A, W70A W42A, W48A, W60A, W70A 2) 0 (510) 20 (510 .0 25 (6.35) W42L, W48L, W60L, W70L W42L, W48L, W60L, W70L 1 Refer to the installation manual for more d
ページ5に含まれる内容の要旨
Electrical Specifications Rated Operating No. Field 2 Minimum 1 Maximum Model Volts Voltage Power Circuit External Fuse and Phase Range Circuits Amps or Circuit Breaker WZ 24A1 - D0 1 16 20 D0524 40/220-1 198-25 1 28 30 D08 1 44 45 WZ 24A1 - F0 1 9 15 415/380-3 3 342-456 W5 24L1 F0 1 11 15 WZ 30A1 - D0 1 23 35 D05 240/220-1 198-254 1 29 35 D10 1 55 60 WZ 30A1 - F0 1 9 15 F07 415/380-3 3 342-456 1 15 15 F12 1 24 25 WZ 36A1 - D0 1 24 35 D0524 40/220-1 198-25 1 29 35 D10 1 55 60 W36A1 - E0Z 1 20
ページ6に含まれる内容の要旨
3 Indoor Blower Performance - CFM (m /s) at 220 Volts W30A W42A, W42L W60A, W60L ESP W24A, W24L W36A, W36L W48A, W48L W70A, W70L in Inches H O 2 Single Speed High Speed Low Speed High Speed Low Speed High Speed Low Speed (Pa) Dry / Wet Coil Dry / Wet Coil Dry / Wet Coil Dry / Wet Coil Dry / Wet Coil Dry / Wet Coil Dry / Wet Coil .00 800 / 845 1160 / 1095 790 / 780 1565 / 1500 1370 / 1330 1825 / 1660 1330 / 1200 (0) (0.38 / 0.40) (0.55 / 0.52) (0.37 / 0.37) (0.74 / 0.71) (0.65 / 0.63) (0.86 / 0
ページ7に含まれる内容の要旨
Cooling Application Data - Outdoor Temperature 1 OUTDOOR TEMPERATURE 1 1 1 1 1 Cooling Model DB/WB 2 2 2 2 2 Capacity 75°F (23.9°C) 85°F (29.4°C) 95°F (35.0°C) 105°F (40.6°C) 115°F (46.1°C) 125°F (51.7°C) 75/62°F Total 22,900 (6.71) 20,600 (6.03) 18,400 (5.39) 16,900 (4.95) 15,500 (4.54) 14,700 (4.30) (23.9/16.7°C) Sensible 17,700 (5.18) 16,900 (4.95) 16,200 (4.74) 15,400 (4.51) 14,500 (4.25) 13,500 (3.95) W24A W24L 80/67°F Total 24,400 (7.14) 22,800 (6.68) 21,200 (6.21) 19,800 (5.80) 18,700 (5
ページ8に含まれる内容の要旨
Air Conditioning Wall-Mount Model Nomenclature W 36 A 1 D 10 X X X X X X SERIES | | CONTROL MODULES (See Chart Below) REVISION KW NOMINAL CAPACITY | | COIL OPTIONS 24 - 2 Ton X - Standard 30 - 2½ Ton 1 - Phenolic Coated Evaporator COLOR OPTIONS 36 - 3 Ton 2 - Phenolic Coated Condenser X - Beige (Standard) VOLTS & PHASE | 42 - 3½ Ton 3 - Phenolic Coated Evaporator 1 - White D - 240/220/50/1 48 - 4 Ton and Condenser VENTILATION OPTIONS 4 - Buckeye Gray E - 220/200/50/3 60 - 5 To