ページ1に含まれる内容の要旨
I-7011/11D, I-7011P/11PD,
I-7018, I-7018P
User Manual
Warranty
All products manufactured by ICP DAS are warranted
against defective materials for a period of one year from the date
of delivery to the original purchaser.
Warning
ICP DAS assume no liability for damages consequent to
the use of this product. ICP DAS reserves the right to change this
manual at any time without notice. The information furnished by
ICP DAS is believed to be accurate and reliable. However, no re-
sponsibility is assume
ページ2に含まれる内容の要旨
Table of Contents 1. Introduction .....................................................5 1.1 More Information.......................................5 1.2 Pin Assignment ..........................................6 1.3 Specifications ............................................8 1.4 Block Diagram.........................................11 1.5 Wire Connection......................................12 1.6 Quick Start ..............................................14 1.7 Default Setting.................
ページ3に含まれる内容の要旨
2.11 $AA6 .....................................................32 2.12 $AA8 .....................................................33 2.13 $AA8V ..................................................34 2.14 $AA9(Data)...........................................35 2.15 $AAB ....................................................36 2.16 $AAF.....................................................37 2.17 $AAM....................................................38 2.18 $AAZ(Data) .................................
ページ4に含まれる内容の要旨
2.35 ~AA2.....................................................57 2.36 ~AA3EVV.............................................58 2.37 ~AA4.....................................................59 2.38 ~AA5PPSS ............................................60 3. Application Note ............................................61 3.1 INIT* pin Operation ................................61 3.2 Module Status..........................................61 3.3 Dual Watchdog Operation .......................62 3.4 Dig
ページ5に含まれる内容の要旨
1. Introduction I-7000 is a family of network data acquisition and control modules. They provide analog-to-digital, digital-to-analog, digital input/output, timer/counter and other functions. These modules can be remote controlled by a set of commands. The common features of I-7011/11D/11P/11PD/18/18P are given as following : 3000VDC Isolated analog input 24-bits sigma-delta ADC to provide excellent accuracy Thermocouple direct connect with build-in CJC Software calibration The I-7011 is a s
ページ6に含まれる内容の要旨
1.2 Pin Assignment I-7011, I-7018 User Manual Rev:B1.0 6
ページ7に含まれる内容の要旨
Rev:B1.0 I-7011, I-7018 User Manual 7
ページ8に含まれる内容の要旨
1.3 Specifications I-7011/I-7011D Analog Input Logic Level 0 : +1V max Input Channel : 1 Logic Level 1 : +3.5 to 30V Input Type : Event Counter mV, V, mA(with external Max Input Frequency : 50 Hz 125 ohms resistor) Min. Pulse Width : 1 mS Thermocouple : Type J, K, Displayed LED T, E, R, S, B, N, C 4½ digits (for I-7011D) Sampling Rate : Power Supply 10 Samples/Second Input : +10 to +30 VDC Bandwidth : 5.24 Hz Consumption : Accuracy : ±0.05% 0.9W for I-7011 Zero Drift : 0.5µV/°C 1.5W for I-7011D
ページ9に含まれる内容の要旨
I-7011P/I-7011PD Analog Input Logic Level 0 : +1V max Input Channel : 1 Logic Level 1 : +3.5 to 30V Input Type : Event Counter mV, V, mA(with external Max Input Frequency : 50 Hz 125 ohms resistor) Min. Pulse Width : 1 mS Thermocouple : Type J, K, Displayed LED T, E, R, S, B, N, C, L, M 4½ digits (for I-7011PD) Sampling Rate : Power Supply 10 Samples/Second Input : +10 to +30 VDC Bandwidth : 5.24 Hz Consumption : Accuracy : ±0.05% 0.9W for I-7011P Zero Drift : 0.5µV/°C 1.5W for I-7011PD Span Dri
ページ10に含まれる内容の要旨
I-7018 I-7018P Analog Input Analog Input Input Channel : Input Channel : 8 differential or 6 differen- 8 differential or 6 differen- tial and 2 single-ended. tial and 2 single-ended. Jumper select. Jumper select. Input Type : Analog Input Type : mV, V, mA(with external mV, V, mA(with external 125 ohms resistor) 125 ohms resistor) Thermocouple : Type J, K, Thermocouple : Type J, K, T, E, R, S, B, N, C T, E, R, S, B, N, C, L, M Sampling Rate : Sampling Rate : 10 Samples/Second 10 Samples/Second Ba
ページ11に含まれる内容の要旨
1.4 Block Diagram Rev:B1.0 I-7011, I-7018 User Manual 11
ページ12に含まれる内容の要旨
1.5 Wire Connection I-7011/11D/11P/11PD Analog I-7011/11D/11P/11PD Digital Input Wire Connection Output Wire Connection I-7018/18P Analog Input Chan- nel 0 to 5 Wire Connection I-7011/11D/11P/11PD Digital Input Wire Connection I-7011, I-7018 User Manual Rev:B1.0 12
ページ13に含まれる内容の要旨
I-7018/18P Analog Input Chan- I-7018/18P Analog Input Chan- nel 6 and 7 Wire Connection, nel 6 and 7 Wire Connection, while the jumper JP1 setting is 8 while the jumper JP1 setting is differential mode. INIT* mode. Rev:B1.0 I-7011, I-7018 User Manual 13
ページ14に含まれる内容の要旨
1.6 Quick Start Refer to “I-7000 Bus Converter User Manual” and “Get- ting Start” for more detail. 1.7 Default Setting Default setting for I-7011/11D/11P/11PD/18/18P : Address : 01 Analog Input Type : Type 05, -2.5 to +2.5 V Baudrate : 9600 bps Checksum disable, 60Hz rejection, engineer unit format I-7018/18P set as INIT* mode, and the analog input is 6 dif- ferential and 2 single-ended. 1.8 Jumper Setting I-7018/18P : Jumper JP1 for select the pin INIT*/Vin 7- Select 8 differential mode, t
ページ15に含まれる内容の要旨
1.9 Calibration Don’t Perform Calibrate Until You Really Understand. Calibration Requirement for I-7011/11D/11P/11PD/18/18P Type Code 00 01 02 03 04 05 06 Min. Input 0 mV 0 mV 0 mV 0 mV 0 V 0 V 0 mA +15 +50 +100 +500 +20 Max Input +1 V +2.5 V mV mV mV mV mA Notification : 1 While calibrate type 06, need connect external shunt resistor, 125 ohms, 0.1% (Ref Sec.1.5). 2 Connect calibration voltage(or current) signal to module’s input. For I-7018/18P, connect to channel 0. (Wire connect ref Sec.1.5
ページ16に含まれる内容の要旨
1.10 Configuration Tables Configuration Table of I-7011/11D/11P/11PD/18/18P : Baudrate Setting (CC) Analog Input Type Setting (TT) T.C Type L and M for I-7011P/11PD/18P only. Data Format Setting (FF) *1 : Filter Select : 0 = 60Hz rejection 1 = 50Hz rejection *2 : Checksum Bit : 0=Disable, 1=Enable *3 : 00 = Engineer Unit Format 01 = Percent Format 10 = 2’s Complement HEX Format I-7011, I-7018 User Manual Rev:B1.0 16
ページ17に含まれる内容の要旨
Analog input type and data format table Type Input Range Data Format +F.S. Zero -F.S. Code Engineer Unit +15.000 +00.000 -15.000 -15 to +15 00 % of FSR +100.00 +000.00 -100.00 mV 2's complement HEX 7FFF 0000 8000 Engineer Unit +50.000 +00.000 -50.000 -50 to +50 01 % of FSR +100.00 +000.00 -100.00 mV 2's complement HEX 7FFF 0000 8000 Engineer Unit +100.00 +000.00 -100.00 -100 to +100 02 % of FSR +100.00 +000.00 -100.00 mV 2's complement HEX 7FFF 0000 8000 Engineer Unit +500.00 +000.00 -500.00 -50
ページ18に含まれる内容の要旨
I-7011, I-7018 User Manual Rev:B1.0 18
ページ19に含まれる内容の要旨
Type Input Range Data Format +F.S. Zero -F.S. Code Engineer Unit +2320.0 +00.000 +00.000 C Type 16 0 to 2320 % of FSR +100.00 +000.00 +000.00 degree Celsius 2's complement HEX 7FFF 0000 0000 Engineer Unit +800.00 +00.000 -200.00 L Type *1 17 -200 to 800 % of FSR +100.00 +000.00 -025.00 degree Celsius 2's complement HEX 7FFF 0000 E000 Engineer Unit +100.00 +000.00 -200.00 M Type *1 18 -200 to 100 % of FSR +050.00 +000.00 -100.00 degree Celsius 2's complement HEX 4000 0000 8000 *1 : Only availabl
ページ20に含まれる内容の要旨
2. Command Command Format : (Leading)(Address)(Command)[CHK](cr) Response Format : (Leading)(Address)(Data)[CHK](cr) [CHK] 2-character checksum (cr) end-of-command character, character return(0x0D) I-7011, I-7018 User Manual Rev:B1.0 20