ページ1に含まれる内容の要旨
Instruction Manual July 2009
multiranger
100/200
ページ2に含まれる内容の要旨
Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by a clarification of the level of caution to be observed. Qualified Personnel: This device/system may only be set up and operated in conjunction with this manual. Qualified personnel are only authorized to install and operate this equipment in accordance with established safety practices an
ページ3に含まれる内容の要旨
mmmmm Table of Contents Table of Contents The MultiRanger 100 and 200 ...............................................................................................................1 MultiRanger 100 ............................................................................................................................1 MultiRanger 200 ............................................................................................................................1 The Manual ......................
ページ4に含まれる内容の要旨
Hand Programmer .......................................................................................................................27 Programmer Keys ........................................................................................................................28 Dolphin Plus ............................................................................................................................................29 Dolphin Plus Toolbar Buttons ......................................
ページ5に含まれる内容の要旨
mmmmm Table of Contents mA I/O ..............................................................................................................................................................49 mA Input [MR 200] ................................................................................................................................49 mA Output ...............................................................................................................................................49 Vol
ページ6に含まれる内容の要旨
Setting the Common Parameters ............................................................................................70 Set Relay 1 (Operate Rake) .......................................................................................................70 Set Relays 2 to 4 (Level Alarms) ..............................................................................................70 External Totalizers and Flow Samplers [MR 200] .................................................................
ページ7に含まれる内容の要旨
mmmmm Table of Contents Communications Installation .............................................................................................................92 Wiring Guidelines ..................................................................................................................................92 Ports 1 and 2 .................................................................................................................................92 Ports 1 and 2: RS-232 RJ-11 Jack and RS
ページ8に含まれる内容の要旨
Error Handling ......................................................................................................................................111 Communication Troubleshooting ...................................................................................................113 Generally ...............................................................................................................................................113 Specifically ............................................
ページ9に含まれる内容の要旨
mmmmm Table of Contents Temperature Compensation (P660 to P664) ..................................................................................181 Rate (P700 to P708) ............................................................................................................................183 Measurement Verification (P710 to P713) ....................................................................................187 Transducer Scanning (P726 to P729) ....................................
ページ10に含まれる内容の要旨
Obstructions in the Sound Beam ......................................................................................... 235 Nozzle Mountings .................................................................................................................... 235 Set the MultiRanger to Ignore the Bad Echo .................................................................... 236 Wrong Reading ...........................................................................................................
ページ11に含まれる内容の要旨
mmmmm MultiRanger 100/200 The MultiRanger 100 and 200 The MultiRanger is available in two models, MultiRanger 100 and MultiRanger 200, and is designed for a variety of applications: water and wastewater storage tanks, for measuring liquids, slurries, and solids hoppers, ore bunkers, flotation cells MultiRanger 100 The MultiRanger 100 is a single or dual-point level, one, three, or six relay measurement device. It is equipped with digital communications and offers the latest in echo proc
ページ12に含まれる内容の要旨
If you have any questions, comments, or suggestions about the manual contents, please email us at techpubs.smpi@siemens.com. For the complete library of Siemens Milltronics manuals, go to www.siemens.com/processautomation. Manual Symbols Please note their use carefully. Alternating Current Direct Current Earth (ground) Terminal Protective Conductor Terminal Caution (refer to instructions) Infra-red communication port on front of instrument RJ-11 communications port No co-axial cable connection
ページ13に含まれる内容の要旨
mmmmm Specifications Specifications Power AC version 1 100-230 V AC ± 15%, 50 / 60 Hz, 36 VA (17W) fuse: F3: 2 AG, Slow Blow, 0.375A, 250V DC version 1 12-30 V DC, 20W fuse: F3: 2 AG, Slow Blow, 2A, 250V Transmitter fuse F1: Belling Lee, L754, 4000A HRC, ceramic type, 100mA, 250V Temperature Sensor fuse F2: Belling Lee, L754, 4000A HRC, ceramic type, 50mA, 250V Mounting Location indoor / outdoor Altitude 2000 m max. Ambient temperature -20 to 50 °C (-5 to 122 °F) Relative humid
ページ14に含まれる内容の要旨
Range 0.3 m (1 ft) to 15 m (50 ft), dependent on transducer Accuracy 0.25% of maximum range or 6 mm (0.24), whichever is greater Resolution 1 0.1% of program range or 2 mm (0.08), whichever is greater Memory 1 MB static RAM with battery backup 512 kB flash EPROM Programming Primary handheld programmer Secondary PC running SIMATIC PDM PC running Dolphin Plus software Display back lit LCD Temperature Compensation Range: -50 to 150 °C (-58 to 302 °F) Source integral transduc
ページ15に含まれる内容の要旨
mmmmm Specifications Fixed 0.17 % per °C deviation from programmed value Outputs Transducer drive 315 V peak mA Analog MultiRanger 100/200: Single or Dual point versions include two mA outputs 0-20 mA 4-20 mA 750 ohm maximum Resolution of 0.1% Isolated 1 Relays One: 1 control Three: 2 control 1 alarm control Six: 4 control 2 alarm control All relays rated 5A at 250 V AC, non-inductive Control Relays 1, 2 or 4 Form A, NO relays (numbers 1, 2, 4, 5) Alarm Relay 0, 1 or
ページ16に含まれる内容の要旨
Inputs mA (analog) (1) [MR 200 only] 0-20 or 4-20 mA, from alternate device, scalable Discrete (2) 10-50 V DC switching level logical 0 = < 0.5 V DC logical 1 = 10 to 50 V DC 3 mA maximum draw Enclosure Wall Mount 240 mm (9.5") x 175 mm (6.9"). Width dimension includes hinges. 1 Type 4X / NEMA 4X / IP 65 Polycarbonate Panel Mount 278 mm (10.93") x 198 mm (7.8") Width dimension includes flange. Type 3 / Nema 3 / IP54 Polycarbonate Weight Wall mount: 1.37 kg (3.02 lb) Pan
ページ17に含まれる内容の要旨
mmmmm Specifications Cable Do not use coaxial cable for transducer (see General Appendix F: Upgrading on page 246 for more information) transducer and mA output signal to be 2 copper conductors, twisted with shield/drain 2 wire, 300 Vrms, 0.324 - 0.823 mm (22 - 18 AWG), nominal capacitance between adjacent conductors @ 1kHz = 62.3 pF/m (19 pF/ft). Nominal capacitance between 1 conductor and shield @ 1kHz = 108.3 pF/m (33 pF/ft) (Belden® 8760 is acceptable) 365 m maximum Note: The Mult
ページ18に含まれる内容の要旨
Installation Notes: Installation must only be performed by qualified personnel, and in accordance with local governing regulations. This product is susceptible to electrostatic shock. Follow proper grounding procedures. All field wiring must have insulation suitable for at least 250 V. Hazardous voltage present on transducer terminals during operation. DC terminals shall be supplied from an SELV source in accordance with IEC 1010-1 Annex H. The non-metallic enclosure does not provid
ページ19に含まれる内容の要旨
mmmmm Installation Mounting Instructions The wall mount and panel mount units install differently. Please follow the specific instructions for your unit. Note: When routing cable through a conduit, please follow the Cable Routing instructions on page 10 before mounting the MultiRanger. Wall Mount Enclosure Dimensions 14.9 mm 160.3 mm 91 mm (0.58") (6.325") (3.58") 15.2 mm 130 mm 4.3 mm dia. (0.17") (0.6") (5.125") 6.6 mm four mounting (0.26") holes lid screws (6) 240 mm (9.45") 227 m
ページ20に含まれる内容の要旨
Cable routed through a conduit: 1. Remove the four mounting screws holding the motherboard to the enclosure. 2. Be careful not to damage the electronics with static electricity. Remove the motherboard from the enclosure by pulling the board straight out. 3. Drill the required cable entry holes. Make sure conduit holes do not interfere with the lower areas on the terminal block, circuit board, or SmartLinx card. 4. Attach the conduit to the enclosure using only approved suitable size hubs for