ページ1に含まれる内容の要旨
H8/3802 Group FP-64E User System
Interface Cable for E6000 Emulator
User’s Manual
H8/3802 HS3802ECH62HE
Renesas Microcomputer Development Environment System
H8 Family/H8/300L Super Low Power Series
Rev.3.00
2003.12.19
ページ2に含まれる内容の要旨
Cautions Keep safety first in your circuit designs! 1. Renesas Technology Corp. puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal injury, fire or property damage. Remember to give due consideration to safety when making your circuit designs, with appropriate measures such as (i) placement of substitutive, auxiliary circuits, (ii) use of nonflam
ページ3に含まれる内容の要旨
IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. User System Interface Cable: Throughout this document, the term "user system interface cable" shall be defined as the following product produced only by Renesas Technology Corp. excluding all subsidiary products. • User system interface cab
ページ4に含まれる内容の要旨
LIMITED WARRANTY Renesas warrants its user system interface cables to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Renesas will repair or replace any user system interface cables determined to be defective in material and/or workmanship. User system interface cables are wearing parts which Renesas will not repair or replace if damaged and/or worn through use. The foregoing shall constitute the sole remedy for any breach of
ページ5に含まれる内容の要旨
State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may have other rights which may vary from state to state. The Warranty is Void in the Following Cases: Renesas shall have no liability or legal responsibility for any problems caused by misuse, abuse, misapplication, neglect, improper h
ページ6に含まれる内容の要旨
SAFETY PAGE READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. DEFINITION OF SIGNAL WORDS This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. DANGER DANGER indicates an imminently hazardous
ページ7に含まれる内容の要旨
WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance. 2. Always switch OFF the E6000 emulator and user system before connecting or disconnecting any CABLES or PARTS. 3. Always before connecting any CABLES, make sure that
ページ8に含まれる内容の要旨
Preface Thank you for purchasing this user system interface cable (HS3802ECH62H) for the Renesas’s original microcomputer H8/3802, H8/38004 group. The HS3802ECH62H is a user system interface cable that connects an H8/3802, H8/38004 group E6000 emulator (HS3800EPI60H; hereinafter referred to as the emulator) to the IC socket for a FP-64E package for the H8/3802, H8/38004 group MCU on the user system. i
ページ9に含まれる内容の要旨
Contents Section 1 Configuration....................................................................................1 Section 2 Connection Procedures ......................................................................3 2.1 Connecting User System Interface Cable to Emulator Station..........................................3 2.2 Connecting User System Interface Cable to User System.................................................5 2.2.1 Installing IC Socket.................................
ページ10に含まれる内容の要旨
Section 1 Configuration CAUTION Use an IC149-064-175-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-64E package IC socket on the user system. Figure 1 shows the configuration of the HS3802ECH62H user system interface cable for the FP-64E package. To emulator station Cable body Screws (M2 x 12 mm) Screws (M2 x 6 mm) with flat washers with flat washers (for fastening cable head) Socket cover Cable head IC socket User system Figure 1 HS3802ECH62H User System Interface C
ページ11に含まれる内容の要旨
Table 1 lists the HS3802ECH62H components. Please make sure you have all of these components when unpacking. Table 1 HS3802ECH62H Components No. Component Quantity Remarks 1 Cable body 1 Flat cable 2 Cable head 1 3 IC socket 1 For the FP-64E package 4 Socket cover 1 For installing an FP-64E-packaged MCU 5 Screws (M2 x 12 mm) 4 For fastening cable head (with four flat washers) 6 Screws (M2 x 6 mm) 4 For installing an FP-64E-packaged MCU (with four flat washers) 7 Documentation 1 User’s manual fo
ページ12に含まれる内容の要旨
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on
ページ13に含まれる内容の要旨
Emulator station Cable body connector User system interface cable Figure 2 Connecting User System Interface Cable to Emulator Station 4 E6000
ページ14に含まれる内容の要旨
2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect the cable head to the user system,
ページ15に含まれる内容の要旨
2.2.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-64E package on the user system with pin 1 on the user system interface cable head, and insert the user system interface cable head into the IC socket on the user system, as shown in figure 3. 2.2.4 Fastening Cable Head CAUTION 1. Use a Philips-type screwdriver whose head matches the screw head. 2. The tightening torque must be 0.13 N•m or less. If the applied torque cannot be a
ページ16に含まれる内容の要旨
Fasten the user system interface cable head to the IC socket for an FP-64E package on the user system with the four screws (M2 x 12 mm; with four flat washers) provided. Each screw should be tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components. Screws (M2 x 12 mm) with flat washers Cable h
ページ17に含まれる内容の要旨
2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable body Removing Push the remove jig Remove jig Cable head User system Figure 4 Fastening Cable Body 8
ページ18に含まれる内容の要旨
2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-64E package (IC149-064-175-B51: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from those of the actual chip's mount pad. 13.50 min 10.10 max 0.50 × 15 = 7.50 ± 0.05 0.50 ± 0.05 0.30 ± 0.05 Unit: mm Figure 5 Recommended Dimensions for Mount Pad 9 0.50 × 15 = 7.5
ページ19に含まれる内容の要旨
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. 25.0 19.3 63.5 Unit: mm Tolerance: ±0.5 mm Figure 6 Dimensions for User System Interface Cable Head 10 16.7 25.0 58.4
ページ20に含まれる内容の要旨
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7. Cable head Unit: mm IC socket Tolerance: ±0.5 mm User system (IC149-064-175-B51 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) Figure 7 Resulting Dimensions after Connecting User System Interface Cable 11 18.6 21.5