ページ1に含まれる内容の要旨
To all our customers
Regarding the change of names mentioned in the document, such as Hitachi
Electric and Hitachi XX, to Renesas Technology Corp.
The semiconductor operations of Mitsubishi Electric and Hitachi were transferred to Renesas
Technology Corporation on April 1st 2003. These operations include microcomputer, logic, analog
and discrete devices, and memory chips other than DRAMs (flash memory, SRAMs etc.)
Accordingly, although Hitachi, Hitachi, Ltd., Hitachi Semiconductors, and othe
ページ2に含まれる内容の要旨
HS3160EPI60HE-P(C) Precautions on Using the H8/3160 Series E6000 Emulator This section shows notes on using the H8/3160 Series E6000 Emulator. 1 Precautions on Using the Emulator 1.1 Note on Compatibility of Session File There is the following note on a session file that has been created at emulation of the H8/3164 device. The session file, which has been created with H8/3160 E6000 Emulator HDI System V3.30 or earlier version, cannot be loaded with H8/3160 E6000 Emulator HDI System V3.30
ページ3に含まれる内容の要旨
1.8 [Disassembly] Window At address specification to open the [Disassembly] window, when a value larger than the maximum one of the absolute address is input, the contents of the last address may not be displayed. In this case, do not perform scrolling with the scroll box on the scroll bar in the [Disassembly] window. If nothing is displayed on the Code or Assembly column in the [Memory] window or [Disassembly] window, close and open again the [Memory] window or [Disassembly] window. 1.9 [Tr
ページ4に含まれる内容の要旨
1.17 [Select Function] Dialog Box The E6000 HDI does not support software breakpoint setting in the [Select Function] dialog box (described in section 10, Selecting Functions, in the Hitachi Debugging Interface User's Manual). 1.18 Note on Radix in [Register] Dialog Box The default input radix in the [Register] dialog box is hexadecimal regardless of the Radix setting. If you want to input the radix other than hexadecimal, specify the prefix code such as B'. 1.19 Note on Moving Source File Pos
ページ5に含まれる内容の要旨
1.24 Usage with Another HDI Automatic load of session files Since the emulator cannot use another HDI, re-install this HDI whenever another HDI has been previously installed is used. If another HDI has been used, initiate this HDI with "Run" as follows without using the session files. \hdi /n (RET) /n initiates the HDI without loading the recently used session files. If there is another session file in the different debug platform, the followi