ページ1に含まれる内容の要旨
Nortel Communication Server 1000
ISDN Basic Rate Interface
Installation and Commissioning
NN43001-318
.
ページ2に含まれる内容の要旨
Document status: Standard Document version: 01.02 Document date: 20 June 2007 Copyright © 2003-2007, Nortel Networks All Rights Reserved. Sourced in Canada The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must take full responsibility for their applications of any products specified in this d
ページ3に含まれる内容の要旨
3 Revision history June 2007 Standard 01.02. This document is up-issued to remove the Nortel Networks Confidential statement. May 2007 Standard 01.01. This document is issued to support Communication Server 1000 Release 5.0. This document contains information previously contained in the following legacy document, now retired: ISDN Basic Rate Interface: Installation and Configuration (553-3001-218). No new content has been added for Communication Server 1000 Release 5.0. All references to Communica
ページ4に含まれる内容の要旨
4 Revision history Nortel Communication Server 1000 ISDN Basic Rate Interface Installation and Commissioning NN43001-318 01.02 Standard Release 5.0 20 June 2007 Copyright © 2003-2007, Nortel Networks .
ページ5に含まれる内容の要旨
5 Contents About this document 9 Subject 9 Applicable systems 10 Intended audience 11 Conventions 11 Related information 11 Preparing for installation 13 Contents 13 Preparing the site 13 Unpacking and inspecting 14 Taking inventory 14 Installing ISDN BRI hardware 15 Contents 15 Installing ISDN BRI hardware for line applications 15 Installing ISDN BRI hardware for trunk applications 38 Preparing the system 47 Contents 47 Introduction 47 Verifying ISDN BRI operation 47 Setting up ISDN BRI test te
ページ6に含まれる内容の要旨
6 Contents Testing an ISDN BRI trunk 103 Removing the test setup 103 Generating traffic reports 105 Contents 105 Introduction 105 Procedures Procedure 1 Selecting the card slots 16 Procedure 2 Remove the module cover for card installation 20 Procedure 3 Installing the MISP 21 Procedure 4 Removing the MISP 21 Procedure 5 Installing the BRSC, SILC, and UILC 22 Procedure 6 Remove the BRSC, SILC, and UILC 23 Procedure 7 Connecting ISDN BRI terminals to the system 23 Procedure 8 Connect the modules to
ページ7に含まれる内容の要旨
Contents 7 Procedure 39 Perform a D-channel Switched Virtual Circuit packet data transmission test using an MPH 101 Procedure 40 Perform a B-channel Switched Virtual Circuit packet data transmission test using an MPH 102 Procedure 41 Perform procedure to test an ISDN BRI trunk DSL 103 Nortel Communication Server 1000 ISDN Basic Rate Interface Installation and Commissioning NN43001-318 01.02 Standard Release 5.0 20 June 2007 Copyright © 2003-2007, Nortel Networks .
ページ8に含まれる内容の要旨
8 Contents Nortel Communication Server 1000 ISDN Basic Rate Interface Installation and Commissioning NN43001-318 01.02 Standard Release 5.0 20 June 2007 Copyright © 2003-2007, Nortel Networks .
ページ9に含まれる内容の要旨
9 About this document This document is a global document. Contact your system supplier or your Nortel representative to verify that the hardware and software described are supported in your area. Note the following: ISDN Basic Rate Interface (BRI) trunking is not available in North America. The Basic Rate Signaling Concentrator (BRSC) is not supported on CS 1000M Cabinet. The integrated Meridian 1 Packet Handler is not supported on CS 1000M Cabinet. Subject This document contains the follo
ページ10に含まれる内容の要旨
10 About this document www.nortel.com Applicable systems This document applies to the following systems: Communication Server 1000S (CS 1000S) Communication Server 1000M Chassis (CS 1000M Chassis) Communication Server 1000M Cabinet (CS 1000M Cabinet) Communication Server 1000M Half Group (CS 1000M HG) Communication Server 1000M Single Group (CS 1000M SG) Communication Server 1000M Multi Group (CS 1000M MG) Communication Server 1000E (CS 1000E) Note: When upgrading software, memory
ページ11に含まれる内容の要旨
Related information 11 Intended audience This document is intended for individuals responsible for the planning, engineering, and administration of the applicable system. Conventions Terminology In this document, the following systems are referred to generically as "system": Communication Server 1000S (CS 1000S) Communication Server 1000M (CS 1000M) Communication Server 1000E (CS 1000E) Meridian 1 The following systems are referred to generically as "Small System": Communication Server
ページ12に含まれる内容の要旨
12 About this document Online To access Nortel documentation online, click the Technical Documentation link under Support & Training on the Nortel home page: www.nortel.com CD-ROM To obtain Nortel documentation on CD-ROM, contact your Nortel customer representative. Nortel Communication Server 1000 ISDN Basic Rate Interface Installation and Commissioning NN43001-318 01.02 Standard Release 5.0 20 June 2007 Copyright © 2003-2007, Nortel Networks .
ページ13に含まれる内容の要旨
13 Preparing for installation Contents This section contains information on the following topics: "Preparing the site" (page 13) "Unpacking and inspecting" (page 14) "Taking inventory" (page 14) Preparing the site When installing a system, address the following factors. environmental structural electrical For more information refer to Communication Server 1000M and Meridian 1 Large System Planning and Engineering (NN43021-220). After the site has been planned, the following items must be c
ページ14に含まれる内容の要旨
14 Preparing for installation 1 Large System Installation and Commissioning (NN43021-310) for a description of how to install the modules. Unpacking and inspecting ISDN BRI cards and external communication cables are shipped in separate packages. To unpack them, follow the general precautions recommended by computer and telephone equipment manufacturers. Remove items that generate static charge from the installation site. If the installation site is carpeted, spray it with an antistatic spra
ページ15に含まれる内容の要旨
15 Installing ISDN BRI hardware Contents This section contains information on the following topics: "Installing ISDN BRI hardware for line applications" (page 15) "Installing ISDN BRI hardware for trunk applications" (page 38) "Selecting the card slots" (page 39) "Removing the module cover for card installation" (page 39) "Installing the MISP" (page 39) "Installing the clock reference on the SILC" (page 39) "Installing the SILC and the UILC" (page 42) "Connecting the system to the Main Distribut
ページ16に含まれる内容の要旨
16 Installing ISDN BRI hardware 4 Install the S/T Interface Linecards (SILCs) and/or U Interface Linecards (UILCs) or Basic Rate Signaling Concentrators (BRSCs). 5 Connect ISDN BRI terminals. This procedure comprises the following: Connect the system to the Main Distribution Frame (MDF). Cross-connect the MDF. Connect ISDN BRI terminals to the DSL. Initialize the ISDN BRI terminals. —End— Procedure 1 Selecting the card slots Step Action To install ISDN BRI cards, perform the following st
ページ17に含まれる内容の要旨
Installing ISDN BRI hardware for line applications 17 2 Locate the card slots in the modules that house ISDN BRI cards. Group all SILCs, UILCs, BRSCs, superloops and the MISP that supports them in the same network group to avoid using junctors for dedicated connections. —End— The following rules apply when selecting the card slots: MISPs MISPs are inserted into the Core/Network Module for Large Systems (Multi Group). Refer to the LD 22 printout to identify modules with unused network card slot
ページ18に含まれる内容の要旨
18 Installing ISDN BRI hardware Group all SILCs, UILCs, BRSCs and the MISP that supports them in the same network group to avoid using junctors for dedicated connections. Figures 1 through 3, beginning Figure 1 "NT8D35 Network module (Large System)" (page 18) show typical module configurations. Figure 1 "NT8D35 Network module (Large System)" (page 18) shows the NT8D35 Network module. Figure 1 NT8D35 Network module (Large System) Figure 2 "NT8D37 IPE module (Large System)" (page 19) shows the NT
ページ19に含まれる内容の要旨
Installing ISDN BRI hardware for line applications 19 Figure 2 NT8D37 IPE module (Large System) Figure 3 "NT4N41 Core/Network module (Large System)" (page 19) shows the NT4N41 Core/Network module. Figure 3 NT4N41 Core/Network module (Large System) Nortel Communication Server 1000 ISDN Basic Rate Interface Installation and Commissioning NN43001-318 01.02 Standard Release 5.0 20 June 2007 Copyright © 2003-2007, Nortel Networks .
ページ20に含まれる内容の要旨
20 Installing ISDN BRI hardware Procedure 2 Remove the module cover for card installation Step Action To remove the covers from the modules with unused card slots, follow the procedure below. Refer to Figure 4 "Module cover locking latches" (page 20). 1 Use a flat-blade screwdriver to unlock the left latch on the front of the cover by turning the screw 1/4 turn clockwise. 2 Use a flat-blade screwdriver to unlock the right latch on the front of the cover by turning the screw 1/4 turn counterclockwi