ページ1に含まれる内容の要旨
Industio CP-114 Series Users Manual
3 in 1 RS-232/422/485 Industrial Serial Board for PCI Bus
Fourth Edition, November 2004
www.moxa.com/product
Moxa Technologies Co., Ltd.
Tel: +886-2-8919-1230
Fax: +886-2-8919-1231
Web: www.moxa.com
MOXA Technical Support
Worldwide: support@moxa.com.tw
The Americas support@moxa.com
ページ2に含まれる内容の要旨
Industio CP-114 Series Users Manual The product described in this manual is furnished under a license agreement and may be used only in accordance with the terms of the agreements. Copyright Notice Copyright 2004, Moxa Technologies Co., Ltd. All rights reserved. Reproduction in any form without permission is prohibited. Trademarks MOXA is a registered trademark of The Moxa Group All other trademarks or registered marks in this manual belong to their respective manufacturers.
ページ3に含まれる内容の要旨
MOXA Internet Services Customer satisfaction is our number one concern, and to ensure that customers receive the full benefit of our products, Moxa Internet Services has been set up to provide technical support, driver updates, product information, and users manual updates. The following services are provided E-mail for technical support ............................... support@moxa.com.tw World Wide Web (WWW) Site for product information: ............................ http://ww
ページ4に含まれる内容の要旨
About This Manual This manual is composed of six chapters and one appendix. This manual is written for installer, system administrator and software programmer. If you are a first-time installer and system administrator, we recommend you to go through the whole manual except Chapter 4. If you are a software programmer, you may refer to chapter 4, Serial Programming Tools. If you need cable wiring information, please see chapter 5, Connection Cable and Cable Wiring. If you enc
ページ5に含まれる内容の要旨
Table of Contents Chapter 1 Introduction .............................................................................................1-1 Overview................................................................................................1-1 Features ................................................................................................1-2 Check List..............................................................................................1-3 Installation Guide...........
ページ6に含まれる内容の要旨
ページ7に含まれる内容の要旨
1 1 1 Introduction Overview Industio - Industrial Multiport Async Solutions for PCI The term Industio stands for smart multiport serial I/O solution for industrial applications. The Industio CP-114 Series boards, including CP-114, CP-114I, CP-114S and CP-114IS, are RS-232/RS-422/RS-485 4-port serial communication interface boards for 32-bit PCI bus with Plug and Play feature. The Industio CP-114 Series support all three serial interfaces, RS-232, RS-422 and RS-485, in one boar
ページ8に含まれる内容の要旨
Operating System Support Support for Windows NT, Windows 95/98 and DOS with user-friendly installation, configuration and performance. MOXA Serial Comm Tools For application development, MOXA provides an easy-to-use serial communication library under Windows NT, Windows 95/98 (PComm) and DOS (API-232). Users can use this library to develop your own applications using Microsoft C, Turbo C, Assembly, QuickBASIC, Turbo Pascal, Clipper, Visual Basic, Visual C++, Borland Delphi, etc. U
ページ9に含まれる内容の要旨
Introduction Check List Upon unpacking the Industio CP-114 Series, you should find items in the package: " Industio CP-114 Series 4 ports serial board×1 " MOXA Software CD-ROM×1, which includes: ! Drivers for MOXA Multiport Async Products ! PComm Lite programming library and utilities for Windows NT/95/98 ! API-232 programming library and utility for DOS ! Users Manual (PDF) " Industio CP-114 Series Users Manual (This manual) " Fan out cable DB37 to 4× DB9 (Male) Installatio
ページ10に含まれる内容の要旨
1-4 Industio CP-114 User's Manual
ページ11に含まれる内容の要旨
2 2 2 Hardware Installation The installation of the Industio CP-114 Series consists of hardware and software installation. The respective sections of the operating systems in the next chapter deal with the software installation. The hardware installation is detailed in this chapter. JP5:Interface selection Jumper for Port 1 JP6:Interface selection Jumper for Port 2 SW2 SW1 RS-422 RS-232 AUTO RS-485 SW1: RS-422/RS-485 Selection Switch for Port 1/2/3/4 RS-485 O
ページ12に含まれる内容の要旨
! S2 Data Mode Selection Switch for Port 1/2/3/4: (Valid if JP5/6 is Left and S1 is ON) ON* Set the RS-485 port to Automatic Data Direction Control Mode. OFF Set the RS-485 port to By RTS Mode. ! JP1/2/3/4 Termination Resistor Port 1/2/3/4: (Valid if JP5/6 is Left and S1 is ON) Open * Not using Termination Resistor Short Using Termination Resistor Installing the Industio CP-114 Series Board The BIOS automatically assigns the IRQ number and I/O addresses for the Industio CP-11
ページ13に含まれる内容の要旨
3 3 3 Software Installation In this chapter, the software driver installation, configuration and driver update/removal procedures are described for various operating systems, including Windows NT, Windows 95/98 and DOS. Before proceeding with the software installation, complete the hardware installation detailed in previous chapter. However, if it is necessary for you to develop your own applications, please refer to the next chapter, Serial Programming Tools, for serial progra
ページ14に含まれる内容の要旨
5. Select MOXA Smartio/Industio Family multiport board in the Select OEM Option dialog box, and click [OK] to enter the Moxa Smartio/Industio Configuration Panel dialog box to start the installation. 3-2 Industio CP-114 User's Manual
ページ15に含まれる内容の要旨
Software Installation 6. In the Moxa Smartio/Industio Configuration Panel dialog box, click [Add] to enter Property dialog box to add the Industio CP-114 Series board. Select the CP-114 Series in the Board Type field. In the Property dialog box, the COM number field of the newly installed board is set to default COM No. If necessary, you may select to change all the ports of the board with the desired COM Number. Note ! You may go
ページ16に含まれる内容の要旨
Rx FIFO trigger levels, at 1, 4, 8 or 14 bytes, are available, and the default value is 14 bytes. ! Tx FIFO Size Tx FIFO sizes from 1 to 16 bytes are available, and the default value is 16 bytes. 8. Click [OK] in the Port # and the Property dialog boxes to go back to the Moxa Smartio/Industio Configuration Panel dialog box. Note ! If you need to install more than one board, click [Add] and repeat steps 6 to 8 to configure another board. Up to four Industio CP-114 Series
ページ17に含まれる内容の要旨
Software Installation Note ! Once the board and the driver are installed and the driver restarts successfully, you can start to develop applications with the PComm library (See Serial Programming Tools) or the Microsoft Win32 API. You can also execute any ready-made applications, such as PComm utility Terminal emulator (See Serial Programming Tools) or HyperTerminal to transmit/receive data, as well as Remote Access Service to provide dial-up networking capabilities. Configur
ページ18に含まれる内容の要旨
Removing Driver To remove the driver for the Industio CP-114 board, 1. Open the [Control Panel], click on the [Network] icon, and select the [Adapters] tab. 2. Select MOXA Smartio/Industio Family Adapter in the adapter list, then click on the [Remove] button and the [OK] button to remove the driver. 3. Restart the system to activate the new configuration. Windows 95/98 Windows 95/98 supports up to 128 serial ports, from COM1 to COM128. To fully integrate the advanced featur
ページ19に含まれる内容の要旨
Software Installation The following flow chart illustrates the driver installation stages of the Industio CP-114 Series boards. Each stage is detailed later. See chapter Hardware Install the Industio PCI board in the system Installation Start Windows 95/98 to detect the board Yes Driver installed before? No Install the driver with the diskette See First Time Driver Installation Stage Configure the port See Port Configuration Stage
ページ20に含まれる内容の要旨
Industio CP-114 User's Manual 3-8