ページ1に含まれる内容の要旨
USER’S
GUIDE
LSIU40HVD
PCI to Dual Channel
SCSI Host Adapter
August 2002
Version 2.2
®
DB15-000101-02
ページ2に含まれる内容の要旨
Electromagnetic Compatibility Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable prote
ページ3に含まれる内容の要旨
This document contains proprietary information of LSI Logic Corporation. The information contained herein is not to be used by or disclosed to third parties without the express written permission of an officer of LSI Logic Corporation. LSI Logic products are not intended for use in life-support appliances, devices, or systems. Use of any LSI Logic product in such applications without written consent of the appropriate LSI Logic officer is prohibited. Document DB15-000101-02, Fourth Edition (August
ページ4に含まれる内容の要旨
iv
ページ5に含まれる内容の要旨
Preface This book is the primary reference and user’s guide for the LSI Logic LSIU40HVD PCI to Dual Channel SCSI Host Adapter. It describes how to install and configure the LSIU40HVD in a PCI computer system. Basic information on setting up the SCSI bus is also provided. LSI Logic Technical Support The entire LSI Logic host adapter solution has been designed for ease of use. However, if you require additional assistance, please contact the LSI Logic Technical Support Hot Line at (719) 533-7230. T
ページ6に含まれる内容の要旨
• Chapter 3, Configuring the LSIU40HVD, describes the SCSI BIOS Configuration Utility to configure adapter and device settings. • Appendix A, Technical Specifications, describes the physical and operational environments of the LSIU40HVD. • Appendix B, Glossary Terms and Abbreviations, provides definitions of various terminology that is referenced throughout this user’s guide. Related Publications PCI Storage Device Management System SDMS™ 4.0 User’s Guide, Order Number S14007.A Revision Record Revisi
ページ7に含まれる内容の要旨
Contents Chapter 1 Using the LSIU40HVD 1.1 General Description 1-1 1.2 Features 1-2 1.2.1 PCI Interface 1-2 1.2.2 SCSI Interface 1-2 1.2.3 Board Characteristics 1-3 1.3 Interface Descriptions 1-3 1.3.1 The PCI Interface 1-3 1.3.2 The SCSI Interface 1-3 1.3.3 Ultra SCSI 1-4 Chapter 2 Installing the LSIU40HVD 2.1 Quick Installation Procedure 2-1 2.2 Detailed Installation Procedure 2-3 2.2.1 Before You Start 2-3 2.2.2 Inserting the Host Adapter 2-4 2.2.3 Connecting the SCSI Peripherals 2-6 2.2.4 SC
ページ8に含まれる内容の要旨
Appendix A Technical Specifications A.1 Physical Environment A-1 A.1.1 Physical Characteristics A-1 A.1.2 Electrical Characteristics A-2 A.1.3 Thermal, Atmospheric Characteristics A-3 A.1.4 Electromagnetic Compliance A-3 A.1.5 Safety Characteristics A-3 A.2 Operational Environment A-4 A.2.1 The PCI Interface A-4 A.2.2 The SCSI Interface A-7 A.2.3 The LED Interface A-9 Appendix B Glossary Terms and Abbreviations Index Customer Feedback viii Contents
ページ9に含まれる内容の要旨
Figures 2.1 Hardware Connections for the LSIU40HVD 2-5 2.2 Inserting the Host Adapter 2-6 2.3 SCSI Cables 2-8 2.4 Internal SCSI Ribbon Cable to Host Adapter Connection 2-9 2.5 Internal SCSI Ribbon Cable to Internal SCSI Device Connection 2-10 2.6 Connecting Additional Internal SCSI Devices 2-11 2.7 Multiple Internal SCSI Devices Chained Together 2-12 2.8 SCSI LED Connectors 2-13 2.9 External Cable to Host Adapter 2-14 2.10 External Cable to External SSI Device 2-15 2.11 Multiple External SCSI De
ページ10に含まれる内容の要旨
x Contents
ページ11に含まれる内容の要旨
Tables 2.1 SCSI Bus Widths and Speeds 2-7 2.2 SCSI ID Record 2-22 2.3 Setting Jumpers 2-23 3.1 Global Default Settings 3-1 3.2 Device Default Settings 3-2 A.1 Maximum Power Requirements A-2 A.2 PCI Connector J1 (Front) A-5 A.3 PCI Connector J1 (Back) A-6 A.4 SCSI Connectors J2/J5 and J3/J6 A-8 A.5 LED Connector J5/J9 A-9 Contents xi
ページ12に含まれる内容の要旨
xii Contents
ページ13に含まれる内容の要旨
Chapter 1 Using the LSIU40HVD This chapter describes how the LSIU40HVD PCI to Dual Channel SCSI Host Adapter interfaces to PCI computer systems and includes these topics: • Section 1.1, “General Description,” page 1-1 • Section 1.2, “Features,” page 1-2 • Section 1.3, “Interface Descriptions,” page 1-3 1.1 General Description The LSI Logic LSIU40HVD provides a SCSI-3, Ultra SCSI interface to PCI computer systems. Installing this adapter in your PCI system allows connection of SCSI devices over a
ページ14に含まれる内容の要旨
1.2 Features This section provides a high level overview of the PCI Interface, the SCSI Interface, and Board Characteristics for the LSIU40HVD. BIOS support for this host adapter is incorporated on the board in an 8 X 64K Flash BIOS. 1.2.1 PCI Interface The PCI interface includes these features: • Full 32-bit DMA bus master • Zero wait-state bus master data bursts • Universal PCI bus voltage support 1.2.2 SCSI Interface The SCSI interface includes these features: • Two identical isolated SCSI ch
ページ15に含まれる内容の要旨
1.2.3 Board Characteristics The board characteristics for the LSIU40HVD are: • PCI board dimensions, 190 x 96.52 mm (7.50 x 3.80 inches) • Universal 32-bit card edge connector 1.3 Interface Descriptions This section provides a more detailed explanation about the PCI Interface, the SCSI Interface, and Ultra SCSI. 1.3.1 The PCI Interface PCI is a high-speed standard local bus for interfacing a number of I/O components to the processor and memory subsystems in a high-end PC. The PCI functionality f
ページ16に含まれる内容の要旨
Connectors J3 and J6 are shielded 68-pin VHDCI right-angle receptacles that protrude through the back panel bracket. See Figure 2.1 for the location of these connectors. Differential SCSI active termination is provided on the LSIU40HVD. Termination is automatically enabled when only one of the connectors J2 and J3 (or J5 and J6) is used, or when an 8-bit device is connected to the 16-bit J3 or J6 connectors. The LSIU40HVD supplies SCSI bus TERMPWR (termination power) through a blocking diode and
ページ17に含まれる内容の要旨
Chapter 2 Installing the LSIU40HVD This chapter provides instructions on how to install the LSIU40HVD and includes these topics: • Section 2.1, “Quick Installation Procedure,” page 2-1 • Section 2.2, “Detailed Installation Procedure,” page 2-3 • Section 2.3, “Setting Interrupts,” page 2-22 • Section 2.4, “Completing the Installation,” page 2-23 2.1 Quick Installation Procedure This section provides quick setup instructions for the experienced computer user with prior host adapter installation an
ページ18に含まれる内容の要旨
Caution: Ground yourself by touching a metal surface before han- dling boards. Static charges on your body can damage electronic components. Handle plug-in boards by the edge. Do not touch board components or gold connector con- tacts. The use of a static ground strap is recommended. Step 4. Locate the slots for PCI plug-in board installation. Refer to the user’s manual for your computer to confirm the location of the PCI slots. The LSIU40HVD requires a PCI slot which allows bus master operation.
ページ19に含まれる内容の要旨
Step 12. Finally, refer to the PCI Storage Device Management System SDMS 4.0 User’s Guide (or the guide for the software that you will use) to load the driver software for your particular operating system. 2.2 Detailed Installation Procedure This section provides step-by-step instructions for installing the LSIU40HVD, and connecting it to your SCSI peripherals. If you are experienced in these tasks, you may prefer to use Section 2.1, “Quick Installation Procedure.” If you are not confident that y
ページ20に含まれる内容の要旨
2.2.2 Inserting the Host Adapter For safe and proper installation, check the user’s manual supplied with your computer and perform the following steps. Step 1. Ground yourself before removing the host adapter board. Remove the LSIU40HVD from the packing and check that it is not damaged. An example of this board is shown in Figure 2.1. Step 2. Switch off and unplug power cords for all components in your system. Step 3. Remove the cabinet cover on your computer to access the PCI slots. Caution: Gr