ページ2に含まれる内容の要旨
Notice The information contained in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Hewlett-Packard assumes no responsibility
ページ3に含まれる内容の要旨
1 Connecting to a Netware 3.12 Server Windows for Workgroups 1 Connecting to a Netware 3.12 Server Windows for Requirements Workgroups • HP Vectra VE7/VE8 with DOS and MS-Windows for Workgroups 3.11 in- stalled. • 3COM 3C339TokenRing card and drivers disk DOS ODI - File Name: tlvmp339.dos DOS and MS-Windows for Workgroups 3.11 media. • Novell Netware server 3.12 that supports Net BEUI, NWLink IPX/SPX, and NWLink NetBIOS transfer protocols. • Netware client for DOS and MS-Windows. Device Con
ページ4に含まれる内容の要旨
1 Connecting to a Netware 3.12 Server Windows for Workgroups 7 Execute INSTALL.EXE. 8 Specify the settings as listed below: ❒ C:\NWCLIENT ❒ Yes ❒ Yes ❒ C:\WINDOWS ❒ No ❒ 3Com Fast Etherlink/Etherlink III Bus Master 9 Under the heading “Select the driver for your network board”, insert the 3Com 3C339 drivers disk and set the path to “A:\NETWARE\CLIENT.” (If you have an HP preloaded HDD, set path to “C:\Masters\LanDrv\3C339\NWCLIENT\) 10 Press “Enter” to continue the installation. 11 When promp
ページ5に含まれる内容の要旨
1 Connecting to a Netware 3.12 Server Windows 95 SR2 Windows 95 SR2 Requirements • HP Vectra VE7/VE8 with Windows 95 SR2 installed. • 3COM 3C 339 Token Ringcard and drivers disk • Windows 95 SR2 media. • Novell Netrware 3.12 server that supports Net BEUI, NWLink IPX/SPX, and NWLink NetBIOS transfer protocols. Device Configuration • I/O Base Address 300 • Interrupt Request Level 10 • Boot PROM Disabled • Transceiver Type Auto Select • Network Driver Optimization Windows or OS/2 Client • Plug
ページ6に含まれる内容の要旨
1 Connecting to a Netware 3.12 Server Windows 95 SR2 (If you have a Hewlett-Packard pre-loaded HDD, set the path statement to “C:\MASTERS\LANDRV\3C509B\”) 11 Highlight the adapter labeled “3Com Token Ring in PCI Mode” and press “OK.” 12 At the “Network” dialogue box, click on the “Identification” folder. 13 Enter your “Computer Name,” “Workgroup,” and “Computer Description.” (If you do not have a Computer name, Workgroup name and Computer description, contact your network administrator.
ページ7に含まれる内容の要旨
2 Connecting to a Netware 4.11 Server Windows for Workgroups 2 Connecting to a Netware 4.11 Server Windows for Requirements Workgroups • HP Vectra VE7/VE8 with DOS and MS-Windows for Workgroups 3.11 in- stalled. • 3COM 3C339TokenRing card and drivers disk DOS ODI - File Name: tlvmp339.dos DOS and MS-Windows for Workgroups 3.11 media. • Novell Netware server 3.12 that supports Net BEUI, NWLink IPX/SPX, and NWLink NetBIOS transfer protocols. • Netware client for DOS and MS-Windows. Device
ページ8に含まれる内容の要旨
2 Connecting to a Netware 4.11 Server Windows for Workgroups 7 Execute INSTALL.EXE. 8 Specify the settings as listed below: ❒ C:\NWCLIENT ❒ Yes ❒ Yes ❒ C:\WINDOWS ❒ No ❒ 3Com Fast Etherlink/Etherlink III Bus Master 9 Under the heading “Select the driver for your network board”, insert the 3Com 3C339 drivers disk and set the path to “A:\NETWARE\CLIENT.” (If you have an HP preloaded HDD, set path to “C:\Masters\LanDrv\3C339\NWCLIENT\) 10 Press “Enter” to continue the installation. 11 When promp
ページ9に含まれる内容の要旨
2 Connecting to a Netware 4.11 Server Windows 95 SR2 Windows 95 SR2 Requirements • HP Vectra VE7/VE8 with Windows 95 SR2 installed. • 3COM 3C 339 Token Ringcard and drivers disk • Windows 95 SR2 media. • Novell Netrware 4.11 server that supports Net BEUI, NWLink IPX/SPX, and NWLink NetBIOS transfer protocols . Device Configuration • I/O Base Address DC00 • Interrupt Request Level 10 • Boot PROM Disabled • Transceiver Type Auto Select • Network Driver Optimization Windows or OS/2 Client • Plu
ページ10に含まれる内容の要旨
2 Connecting to a Netware 4.11 Server Windows 95 SR2 10 Insert the 3C339 drivers diskette and set path to “A:\” and hit Enter. (If you have a Hewlett-Packard pre-loaded HDD, set the path statement to “C:\MASTERS\LANDRV\3C509B\”) 11 Highlight the adapter labeled “3Com Token Ring in PCI Mode” 12 and press “OK.” 13 At the “Network” dialogue box, click on the “Identification” folder. 14 Enter your “Computer Name,” “Workgroup,” and “Computer Description.” (If you do not have a Computer name,
ページ11に含まれる内容の要旨
3 Connecting to a Windows NT Server 3.51 Windows for Workgroups Ver. 3.11 3 Connecting to a Windows NT Server 3.51 Windows for Requirements Workgroups Ver. 3.11 • HP Vectra VE7/VE8 with DOS and MS-Windows for Workgroups 3.11 in- stalled. • 3COM Token Ring 3C339 card and drivers disk ver. 5.0. DOS ODI - File Name: Tl3c3x9.dos Size: 52KB Date: 2/28/97 • DOS and MS-Windows for Workgroups 3.11 media. • Microsoft Windows NT Server 3.51 machine that supports Net BEUI, NWLink IPX/SPX, and NWLink N
ページ12に含まれる内容の要旨
3 Connecting to a Windows NT Server 3.51 Windows for Workgroups Ver. 3.11 ❒ C:\WINDOWS ❒ No 9 Under the heading “Select the driver for your network board”, insert the 3Com 3C339 drivers disk and set the path to “A:\NETWARE\CLIENT.” (If you have an HP preloaded HDD, set path to “C:\Masters\LanDrv\3C339\NWCLIENT\) 10 Press “Enter” to continue the installation. 11 When prompted, insert the corresponding disks to complete file transfer and driver installation. 12 When the install utility is fini
ページ13に含まれる内容の要旨
3 Connecting to a Windows NT Server 3.51 Windows 95 SR2 Windows 95 SR2 Requirements • HP Vectra VE7/VE8with Windows 95 SR2. • 3COM TokenRing 3C 339 card and drivers disk • Windows 95 media. • Microsoft Windows NT Server 3.51 machine that supports Net BEUI, TCP/ IP, NWLink IPX/SPX, and NWLink NetBIOS transfer protocols. Device Configuration • I/O Base Address DC00 • Interrupt Request Level 10 • Boot PROM Disabled • Transceiver Type Auto Select • Network Driver Optimization Windows or OS/2 Clie
ページ14に含まれる内容の要旨
3 Connecting to a Windows NT Server 3.51 Windows 95 SR2 10 In the “Network” dialog box , click on the “Add” button . 11 In the “Select Network Component Type” dialog box, highlight “Adapter” then click on “Add.” 12 Click on “Have Disk” in the “Select Network adapters” dialog box. 13 Insert the 3COM Software “Etherlink 3C339 Token Ring Drivers ” disk into the floppy drive. 14 With the Path set to “A:\” in the “Install From Disk” dialog box click “OK”. (If you have an HP pre-loaded HDD, s
ページ15に含まれる内容の要旨
3 Connecting to a Windows NT Server 3.51 Windows NT Workstation Version 3.51 Windows NT Requirements Workstation • HP Vectra VE7/VE8 with Microsoft Windows NT Workstation 3.51 in- Version 3.51 stalled. • 3COM 3C339 card and drivers disk • Microsoft Windows NT Workstation 3.51 and Service Pack Media. • Microsoft Windows NT Server 3.51 machine that supports Net BEUI, TCP/ IP, NWLink IPX/SPX, and NWLink NetBIOS transfer protocols. Device Configuration • I/O Base Address DC00 • Interrupt Request
ページ16に含まれる内容の要旨
3 Connecting to a Windows NT Server 3.51 Windows NT Workstation Version 3.51 9 Double click on the “Network” icon and agree to install Windows NT Networking on your computer. 10 Insert the Windows NT Workstation CD. 11 In “Windows NT Setup”, enter the path to your NT files and click on “Continue.” (If you have an HP preloaded HDD, set path to “C:\I386”) 12 Click on “Do Not Detect” from the “ Network Adapter Card Detection” dialog box, and click on “Continue” in the second “Network Adapter
ページ17に含まれる内容の要旨
3 Connecting to a Windows NT Server 3.51 Windows NT Workstation 4.0 Windows NT Requirements Workstation 4.0 • HP Vectra VE7/VE8 with Microsoft Windows NT Workstation 4.0 in- stalled. • 3COM 3C339 card and drivers disk • Microsoft Windows NT Workstation 4.0 and Service Pack Media. • Microsoft Windows NT Server 3.51 machine that supports Net BEUI, TCP/ IP, NWLink IPX/SPX, and NWLink NetBIOS transfer protocols. Device Configuration • I/O Base Address DC00 • Interrupt Request Level 10 • Boot PRO
ページ18に含まれる内容の要旨
3 Connecting to a Windows NT Server 3.51 Windows NT Workstation 4.0 9 Double click on the “Network” icon and agree to install Windows NT Networking on your computer. 10 Insert the Windows NT Workstation CD. 11 In “Windows NT Setup”, enter the path to your NT files and click on “Continue.” (If you have an HP preloaded HDD, set path to “C:\I386”) 12 Click on “Do Not Detect” from the “ Network Adapter Card Detection” dialog box, and click on “Continue” in the second “Network Adapter Card Det
ページ19に含まれる内容の要旨
4. Connecting to a Windows NT Server 4.0 Windows for Workgroups Ver. 3.11 4. Connecting to a Windows NT Server 4.0 Windows for Requirements Workgroups • HP Vectra VE7/VE8 with DOS and MS-Windows for Workgroups 3.11 in- Ver. 3.11 stalled. • 3COM Token Ring 3C339 card and drivers disk ver. 5.0. DOS ODI - File Name: Tl3c3x9.dos Size: 52KB Date: 2/28/97 • DOS and MS-Windows for Workgroups 3.11 media. • Microsoft Windows NT Server 4.0 machine that supports Net BEUI, NWLink IPX/SPX, and NWLink N
ページ20に含まれる内容の要旨
4. Connecting to a Windows NT Server 4.0 Windows for Workgroups Ver. 3.11 ❒ C:\WINDOWS ❒ No 9 Under the heading “Select the driver for your network board”, insert the 3Com 3C339 drivers disk and set the path to “A:\NETWARE\CLIENT.” (If you have an HP preloaded HDD, set path to “C:\Masters\LanDrv\3C339\NWCLIENT\) 10 Press “Enter” to continue the installation. 11 When prompted, insert the corresponding disks to complete file transfer and driver installation. 12 When the install utility is fini