ページ1に含まれる内容の要旨
NETWORK SOUNDER
ETR-30N
ページ2に含まれる内容の要旨
SAFETY INSTRUCTIONS WARNING WARNING ELECTRICAL SHOCK HAZARD Install the transducer tank according Do not open the equipment to the installation instructions. unless totally familiar with electrical circuits and Failure to install the tank correctly may service manual. result in water leakage and damage to the ship's hull. Only qualified personnel should work inside the equipment. Turn off the power at the switchboard before beginning the installation. Fire or electrical shock can result if the
ページ3に含まれる内容の要旨
CAUTION CAUTION Ground the equipment to The transducer cable must be handled prevent mutual interference. carefully, following the guidelines below. • Keep fuels and oils away from the Observe the following compass safe cable. distances to prevent interference to a • Locate the cable where it will not be magnetic compass: damaged. • The cable sheath is made of chloro- Standard Steering phrene or polychloride vinyl, which compass compass is easily damaged by plastic solvents 1.7 m
ページ4に含まれる内容の要旨
TABLE OF CONTENTS SYSTEM CONFIGURATION................................................................................ iv EQUIPMENT LISTS ............................................................................................. vi 1. MOUNTING ...................................................................................................... 1 1.1 Network Sounder.............................................................................................................1 1.2 Tran
ページ5に含まれる内容の要旨
SYSTEM CONFIGURATION Single network sounder NavNet Series NavNet Radar Network Sounder Display Unit ETR-30N NavNet Series NavNet Radar HUB* Display Unit NavNet Display Unit NavNet Rectifier Ship’s Mains Display Unit PR-62 12-24 VDC NavNet Display Unit 100/110/115/220/230 VAC, 1φ, 50/60 Hz : Standard : Option Low High : Local Supply Freq. Freq. Transducer Transducer * = By using a hub, one NavNet series radar and three NavNet display units may be connected. System configuration, single networ
ページ6に含まれる内容の要旨
Multiple network sounders NavNet Series NavNet Radar HUB*1 Display Unit Network Sounder NavNet ETR-30N Display Unit NavNet *3 Display Unit Network Sounder ETR-6/10N*2 : Standard : Optional Supply : Local Supply *1 = By using a hub, one NavNet series radar and two NavNet display units may be connected. *2 = Maximum two network sounders may be installed. *3 = Connect to NET KP. System configuration, two ETR-30N NavNet Series NavNet Radar HUB* Display Unit Network Sounder NavNet ETR-30N Disp
ページ7に含まれる内容の要旨
EQUIPMENT LISTS Standard supply Name Type Code No. Qty Remarks Network ETR-30N — 1 Sounder Spare Parts* SP02-04601 002-180-150 1 set Installation CP02-07100 — • Power Cable Materials* (w/NavNet MJ-A3SPF0013-035 connection • NavNet connection cable cable) MJ-A6SPF0014-050 (5 m) 1 set • CP02-07101 CP02-07110 — • Power Cable (No NavNet MJ-A3SPF0013-035 connection • CP02-07101 cable) * = See packing list at end of manual. Optional supply Name Type Code No. Remarks Piggyback O
ページ8に含まれる内容の要旨
Available transducers 1kW transducer Freq. Ship Transducer Thru-hull pipe Tank (kHz) 28F-8 (000-015-003) Steel — — 50B-6 (000-015-042) 50B-6B (000-015-043, 15M) (000-015-018, 30M) FRP — — (000-015-255, 40M) 28/50 TWB-6000 (2) T-656 Steel 28F-8 (000-015-003) (000-015-207) (000-015-982) 50B-9 (000-138-574) FRP — — 50B-9B (000-015-065) Steel — — 28F-8 (000-015-003) 50F-8G (000-015-066) FRP — — Steel — — 28F-8 (000-015-003) 28/68 68F-8H (000-015-067) FRP — — TWB-6000 (
ページ9に含まれる内容の要旨
1kW transducer (con’t) Freq. Ship Transducer Thru-hull pipe Tank (kHz) 50B-6 (000-015-042) Steel — — 50B-6B (000-015-043, 15M) (000-015-018, 30M) (000-015-255, 40M) FRP — — 200B-5S (000-015-029) 50B-9 (000-138-574) Steel — — 50B-9B (000-015-065) FRP — — 200B-5S (000-015-029) 50/200 Steel — — 50F-8G (000-015-066) 200B-5S (000-015-029) FRP — — Steel — — 50/200-1T (000-015-170) FRP — — Steel — — 50/200-1ST (000-015-110) FRP — — Steel — — 68F-8H (000-015-067) 68/200 200B
ページ10に含まれる内容の要旨
2kW transducer Freq. Ship Transducer Thru-hull pipe Tank (kHz) TFB-7000 (2) T-634 28F-18 (000-015-004, 15M) Steel (000-015-209) (000-015-810) 28/50 (000-138-573, 30M) 50B-12 (000-015-020) FRP — — Steel — — 28F-18 (000-015-004, 15M) 28/68 (000-138-573, 30M) TRB-1100 (2) T-634-F FRP 68F-30H (000-015-073) (000-015-218) (000-015-811) TFB-7000 (2) T-636 Steel 28F-18 (000-015-004, 15M) (000-015-209) (000-015-813) (000-138-573, 30M) 28/88 TRB-1100 (2) T-636-F 88B-10 (000-015-
ページ11に含まれる内容の要旨
3kW transducer Freq. Ship Transducer Thru-hull pipe Tank (kHz) Steel — — 28F-24H (000-015-075) 28/45 45F-12H (000-015-076) FRP — — TFB-7000 (2) T-681 Steel (000-015-209) (000-015-849) 28F-24H (000-015-075) 50F-24H (000-138-582) TRB-1100 (2) T-681-F FRP (000-015-218) (000-015-850) 28/50 TWB-6000 (2) T-696 Steel (000-015-207) (000-015-048) 28F-24H (000-015-075) 50BL-24H (000-015-247) TRB-1100 (2) T-696-F FRP (000-015-218) (000-015-244) — — Steel 28F-24H (000-015-075) 2
ページ12に含まれる内容の要旨
3kW transducer (con’t) Freq. Ship Transducer Thru-hull pipe Tank (kHz) TFB-7000 (2) T-683 Steel 50F-24H (000-138-582) (000-015-209) (000-015-853) 50/150 150B-12H (000-015-074) TRB-1100 (2) T-683-F FRP (000-015-218) (000-015-854) TFB-7000 (2) T-683 Steel (000-015-209) (000-015-853) 50F-24H (000-138-582) 200B-12H (000-015-069) TRB-1100 (2) T-683-F FRP (000-015-218) (000-015-854) 50/200 TWB-6000 (2) T-695 Steel (000-015-207) (000-015-047) 50BL-24H (000-015-247) 200B-12H (
ページ13に含まれる内容の要旨
1kW/2kW transducer Freq. Output Ship Transducer Thru-hull pipe Tank (W) (kHz) Steel — — 28F-8 (000-015-003) 28/50 50B-12 (000-015-020) FRP — — Steel — — 28F-8 (000-015-003) 28/68 68F-30H (000-015-073) FRP — — Steel — — 28F-8 (000-015-003) 28/88 88B-10 (000-015-025) FRP — — TWB-6000 (2) T-657 28F-8 (000-015-003) Steel (000-015-207) (000-015-983) 200B-8 (000-015-030) 28/200 200B-8B (000-015-032) FRP — — 200B-8N (000-015-045) Steel — — 45F-3H 45/88 88B-10 (000-015-0
ページ14に含まれる内容の要旨
1kW/2kW transducer (con’t) Freq. Output Ship Transducer Thru-hull pipe Tank (W) (kHz) TFB-7000 (2) T-638 50F-8G (000-015-066) Steel (000-015-209) (000-015-818) 200B-8 (000-015-030) 50/200 200B-8B (000-015-032) TRB-1100 (2) T-638-F FRP 200B-8N (000-015-045) (000-015-218) (000-015-819) 68F-8H (000-015-067) Steel — — 200B-8 (000-015-030) 68/200 200B-8B (000-015-032) FRP — — 200B-8N (000-015-045) 88B-8 (000-015-024) TWB-6000 (2) T-659 Steel 200B-8 (000-015-030) (000-0
ページ15に含まれる内容の要旨
1kW/3kW transducer (con’t) Freq. Output Ship Transducer Thru-hull pipe Tank (W) (kHz) Steel — — 50F-8G (000-015-066) 50/88 88F-126H (000-015-068) FRP — — 50B-6 (000-015-042) Steel — — 50B-6B (000-015-043, 15M) (000-015-018, 30M) FRP — — (000-015-255, 40M) 150B-12H (000-015-074) 50/150 50B-9 (000-138-574) Steel — — 50B-9B (000-015-065) FRP 150B-12H (000-015-074) — — Steel — — 50F-8G (000-015-066) 150B-12H (000-015-074) FRP — — 50B-6 (000-015-042) Steel — — 50B
ページ16に含まれる内容の要旨
1kW/3kW transducer (con’t) Freq. Output Ship Transducer Thru-hull pipe Tank (W) (kHz) Steel — — 68F-8H (000-015-067) 68/200 200B-12H (000-015-069) FRP — — Steel — — 88B-8 (000-015-024) 1 k/3 k 88/150 150B-12H (000-015-074) FRP — — Steel — — 88B-8 (000-015-024) 88/200 200B-12H (000-015-069) FRP — — xv
ページ17に含まれる内容の要旨
2kW/3kW transducer Freq. Output Ship Transducer Thru-hull pipe Tank (W) (kHz) 28F-18 (000-015-004, 15M) Steel — — (000-138-573, 30M) 28/45 FRP — — 45F-12H (000-015-076) 28F-18 (000-015-004, 15M) Steel — — (000-138-573, 30M) 28/50 FRP — — 50F-24H (000-015-077) 28F-18 (000-015-004, 15M) Steel — — 28/68 (000-138-573, 30M) FRP — — 68F-30H (000-015-073) 28F-18 (000-015-004, 15M) Steel — — 28/88 (000-138-573, 30M) FRP — — 88F-126H (000-015-068) TFB-7000 (2) T-637 Steel 28
ページ18に含まれる内容の要旨
3kW/2kW transducer (con’t) Freq. Output Ship Transducer Thru-hull pipe Tank (W) (kHz) Steel — — 28F-24H (000-015-075) 28/50 50B-12 (000-015-020) FRP — — Steel — — 28F-24H (000-015-075) 28/68 68F-30H (000-015-073) FRP — — Steel — — 28F-24H (000-015-075) 28/88 88B-10 (000-015-025) FRP — — 28F-24H (000-015-075) Steel — — 200B-8 (000-015-030) 28/200 200B-8B (000-015-032) FRP — — 200B-8N (000-015-045) Steel — — 45F-12H (000-015-076) 45/88 88B-10 (000-015-025) FRP — —
ページ19に含まれる内容の要旨
1. MOUNTING 1.1 Network Sounder 1.1.1 Mounting considerations The network sounder can be installed on the deck or on the bulkhead. When selecting a mounting location, keep the following points in mind: • The temperature and humidity of the mounting location should be moderate and stable. • Locate the unit away from exhaust pipes and vents. • The mounting location should be well ventilated. • Do not install the equipment where it may get wet from rain or water splash. • Mount the unit
ページ20に含まれる内容の要旨
1.1.3 Stacking units You may stack two network sounders by using the optional piggyback mount kit (Type OP02-84, Code No. 002-186-170) as below. Note: Change the tap setting on the lower unit before installing the upper unit. See paragraph 2.2 for how to change tap setting. Contents of piggyback mount kit Name Type Code No. Qty Remarks Jointing Fixture (LWR) 02-142-1131 100-300-211 1 Jointing Fixture (UPR) 02-142-1132 100-300-221 1 Hexagon Head Bolt B M5 x 12 000-803-147 2 Pan Hea