MULTI-TASKER
MANUAL PART NUMBER: 400-0097-004
MT106-101
SCAN DOUBLER CARD FOR
TM
MULTI-TASKER USER’S GUIDE
ページ2に含まれる内容の要旨
MULTI-TASKER TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS..............2 1.1 GENERAL...................................................2 1.2 INSTALLATION ..........................................2 1.3 CLEANING..................................................2 1.4 FCC / CE NOTICE ......................................2 ABOUT YOUR MT106-101 ..................................3 TECHNICAL SPECIFICATIONS .........................3 DESC
ページ3に含まれる内容の要旨
MULTI-TASKER PRECAUTIONS / SAFETY WARNINGS 1 • This equipment has been tested and found to comply with the limits for a Class A digital Please read this manual carefully before using your device, pursuant to Part 15 of the FCC Rules. MT106-101. Keep this manual handy for future These limits are designed to provide reasonable reference. These safety instructions are to ensure protection against harmful interference when the the long life of
ページ4に含まれる内容の要旨
MULTI-TASKER ABOUT YOUR MT106-101 2 TECHNICAL SPECIFICATIONS 3 FEATURES/DESCRIPTION MT106-101 MT106-101 Scan Doubler Card GENERAL The MT106-101 is a Scan Doubler Card designed Inputs for use with the Multi-Tasker™ system. When (3) BNC Female Composite Video installed in a Multi-Tasker™ enclosure, this card Connectors allows the connection of an S-Video or one of three (1) 4-pin Mini-DIN S-Video Composite Video (NTSC/PAL) sources to a data-
ページ5に含まれる内容の要旨
MULTI-TASKER DESCRIPTION OF MT106-101 4 4
ページ6に含まれる内容の要旨
MULTI-TASKER APPLICATION DIAGRAM 5 Application 1 Application 2 5
ページ7に含まれる内容の要旨
MULTI-TASKER Application 2: Internal View of MT106-101 6
ページ8に含まれる内容の要旨
MULTI-TASKER 1. Square brackets “[ ]” are part of the INSTALLING YOUR MT106-101 6 command. Step 1. Slide the MT106-101 into an available slot 2. Use uppercase letters for all commands. in the Multi-Tasker™ Basic Enclosure in order to connect to the bus. Make sure After processing a command, an OK or ER that the MT106-101 Scan Doubler card string will be returned as feedback if "F" is fits into place. Secure the card to the included at the
ページ9に含まれる内容の要旨
MULTI-TASKER Ui = Unit ID (i = # from 0 to 9) (refer to the 4. [CLR] MT100-100 user’s guide for explanation) This command resets the card configuration to Example: factory defaults. If one Scan Doubler Card is in slot #2 of unit 3. Command Format: [CLRCi] Send the command [VERC2U3], and the Multi-Tasker™ Basic Enclosure will return the Ci = card ID (n = a slot # from 1 to 19) (1-8 for MT100-101 or 1-4 for MT100-106) following: Example: MT
ページ10に含まれる内容の要旨
MULTI-TASKER Example: STATUS MIN MAX Default There is an MT106-101 in slot 7 of unit ID 4. Command Value Value Value Set the Horizontal Position to the maximum [ HPOS ] 0 20 5 value of 20 by sending the command [ VPOS ] 0 20 19 [HPOS20C7U4]. [ HSIZE ] 0 20 19 8. [HPOSCi] - Status/Adjust [ VSIZE ] 0 20 19 This command selects the Horizontal Position [ BRIG ] 0 20 10 adjustment and makes it the active control. It is [ SHARP ] 0
ページ11に含まれる内容の要旨
MULTI-TASKER This command selects the Vertical Position Example: adjustment and makes it the active control. It There is an MT106-101 in slot 2 of unit ID 3. also returns the status of the current Vertical View the current Horizontal Size and adjust the Position. As the active control, it may be image to the center of the screen. adjusted using the [ + ] and [ - ] commands. [HSIZEC2U3] 10 Command Format: [VPOSCiUy] [HSIZEC2U3] = STATUS/C
ページ12に含まれる内容の要旨
MULTI-TASKER 15. [BRIGnCi] - Set Value Ci = card ID (i = slot number) This command selects the Brightness Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation) adjustment and makes it the active control. It also returns the status of the current Brightness Example: level. As the active control, it may be adjusted There is an MT106-101 in slot 4 of unit ID 2. using the [ + ] and [ - ] commands. Set the Sharpness
ページ13に含まれる内容の要旨
MULTI-TASKER 20. [COLORCi] - Status/Adjust Command Format: [HUECiUy] The COLOR command, with no value, selects Ci = card ID (i = slot number) the Color adjustment and makes it the active Uy = unit id (i = 0 to 9) (refer to the MT100-100 control. It is also used to return the status of the user’s guide for explanation) current Color level. As the active control, it may be adjusted using the [ + ] and [ - ] commands. Example: There is an
ページ14に含まれる内容の要旨
MULTI-TASKER 25. [CLR] C1C2C19 G5U1. This command clears the members for a single group or for all nine groups. 7.3 SUMMARY OF COMMANDS Command Format: [CLRGkUi] 1) [VER] Receives software version Gk = group number (k = # from 1-9) 2) [Ci] Receives status of the card Ui = unit number (i = # from 0-9) 3) [SIG] Signal present command Example: 4) [CLR] Resets card to defaults 1) To clear group #1, send the [CLRG1U1] command. This command
ページ15に含まれる内容の要旨
MULTI-TASKER Solution 2: Verify that all IC’s are seated in their TROUBLESHOOTING GUIDE 8 sockets. If the LED is still blinking We have carefully tested and have found no red, see Cause 2. problems in the supplied MT106-101; however, we Cause 2: The card and its serial device are would like to offer suggestions for the following: not communicating. • 8.1 LED IS NOT LIT Solution 1: Turn the system OFF and then ON • 8.2 LED IS BLINKING RED a
ページ16に含まれる内容の要旨
MULTI-TASKER ALTINEX POLICY 9 9.1 LIMITED WARRANTY/RETURN POLICY Please see the Altinex website at www.altinex.com for details on warranty and return policy. 9.2 CONTACT INFORMATION ALTINEX, INC 592 Apollo street Brea, CA 92821 USA TEL: 714 990-2300 TOLL FREE: 1-800-ALTINEX WEB: www.altinex.com E-MAIL: solutions@altinex.com 15