ページ1に含まれる内容の要旨
FK1471 P0109YI
JKW-BA
Long Distance Adaptor for JK Series
Adaptateur longue distance pour la série JK
Adaptador de larga distancia para la Série JK
Langeafstandsadapter voor reeks JK
Adattatore per grandi distanze per la serie JK
JKW-BA
Long Distance Adaptor for JK Series
Adaptateur longue distance pour systèmes
d'entrée vidéo couleur JK
Adaptador de larga distancia para sistemas de
entrada de video a color JK
Langeafstandsadapter voor kleuren-
videofoniesystemen JK
Adattatore per grandi dist
ページ2に含まれる内容の要旨
PRECAUTIONS General Prohibitions Prohibition to Dismantle the Unit Prohibition on Subjecting the Unit to Water General Precautions WARNING General Precautions 1. This unit is for indoor use only. Do not use outdoors. (Negligence could result in death or serious injury.) 2. If the unit is down or does not operate properly, unplug the power supply or turn off 1. Do not dismantle or alter the unit. Fire or electric shock could result. the unit power switch. 2. Do not connect any power sou
ページ3に含まれる内容の要旨
English Français Español Nederlands Italiano MOUNTING 3 Mount on the din rail and lock. Pull down the lock release lever to remove. Din rail Din rail Lock release lever WIRING 4 4-1 WIRING JK-DA JK-DV JK-1MED/JK-1MD JKW-BA JK-DVF 2 2 A1 A1 B1 A1 A2 A2 B2 A2 NP NP + + - - 2 2 P P NP : Non-polarized PS-1820 PS18 P: Polarized PS-1810DIN PS-1820DIN 4-2 Cable 1 Use PVC jacket with PE (polyethylene) insulated cable (x2) 2 Never use individual conductors, twisted pair cable or coaxial cable. - 3 -
ページ4に含まれる内容の要旨
4-3 Wiring distance JK-1MED JK-DA JKW-BA A B JK-1MD D JK-DV JK-DVF C PS18 B JK-1MED JK-1HD JK-DA JKW-BA A JK-1SD JK-1MD JK-DV D JK-DVF C PS18 Ø 0.65 mm 22 AWG Ø 1.0 mm 18 AWG A 100 m 330' 200 m 650' B 50 m 165' 100 m 330' C 50 m 165' 100 m 330' D 5 m 16' 10 m 33' Connect each of the connecting units with a wiring distance within the values listed in the table above. If units are connected with wiring distances outside of these ranges, this will adversely affect picture quality. SPECIFICATIONS 5
ページ5に含まれる内容の要旨
4-3 Distanza di cablaggio JK-1MED JK-DA JKW-BA A B JK-1MD D JK-DV JK-DVF C PS18 B JK-1MED JK-1HD JK-DA JKW-BA A JK-1SD JK-1MD JK-DV D JK-DVF C PS18 Ø 0,65 mm 22 AWG Ø 1,0 mm 18 AWG A 100 m 330’ 200 m 650’ B 50 m 165’ 100 m 330’ C 50 m 165’ 100 m 330’ D 5 m 16’ 10 m 33’ Collegare ciascuna delle unità di connessione utilizzando un tratto di cablaggio avente una lunghezza che rientra nei valori elencati nella tabella sopra. Se si dovessero collegare le unità con un tratto di cablaggio avente una lu