ページ1に含まれる内容の要旨
TA 544 User Manual/61200704L1-1A
Page 1 of 68
TA 544
User Manual
1200704L1 TA 544
4200704L3 TA 544 with SDSL Card
61200704L1-1A
May 2001
© 2001, ADTRAN, Inc. TA 544 User Manual
ページ2に含まれる内容の要旨
TA 544 User Manual/61200704L1-1A Page 2 of 68 Trademarks Any brand names and product names included in this manual are trademarks, registered trademarks, or trade names of their respective holders. Total Access is a registered trademark of ADTRAN, Inc. To the Holder of the Manual The contents of this manual are current as of the date of publication. ADTRAN reserves the right to change the contents without prior notice. In no event will ADTRAN be liable for any special, incidental, or consequenti
ページ3に含まれる内容の要旨
TA 544 User Manual/61200704L1-1A Page 3 of 68 Notes provide additional useful information. Caution signify information that could prevent service interruption. Warnings provide information that could prevent damage to the equipment or endangerment to human life. Safety Instructions When using your telephone equipment, please follow these basic safety precautions to reduce the risk of fire, electrical shock, or personal injury: 1. Read and understand all instructions. 2. Follow all warnings and i
ページ4に含まれる内容の要旨
TA 544 User Manual/61200704L1-1A Page 4 of 68 Limited Product Warranty ADTRAN warrants that for 5 years from the date of shipment to Customer, all products manufactured by ADTRAN will be free from defects in materials and workmanship. ADTRAN also warrants that products will conform to the applicable specifications and drawings for such products, as contained in the Product Manual or in ADTRAN's internal specifications and drawings for such products (which may or may not be reflected in the Produ
ページ5に含まれる内容の要旨
TA 544 User Manual/61200704L1-1A Page 5 of 68 International Contact Information ADTRAN, Inc. Attention: International Department 901 Explorer Boulevard Huntsville, Alabama 35806 USA www.adtran.com Asia Pacific—Beijing, China 8610 8529-8895 voice 8610 8529-8866 fax sales.china@adtran.com Asia Pacific—Hong Kong 852 2824-8283 voice 852 2824-8928 fax sales.asia@adtran.com Asia Pacific—Melbourne, Australia 61 3 9225-5114 voice 61 3 9225-5050 fax sales.asia@adtran.com Canada--Ontario 1 416 290-0585 vo
ページ6に含まれる内容の要旨
TA 544 User Manual/61200704L1-1A Page 6 of 68 Northern Europe/Russia--London, United Kingdom 44 1252 626-730 voice 44 1252 617-850 fax sales.northeurope@adtran.com U.S. Headquarters 1 256 963-8000 voice 1 256 963-6300 fax 1 256 963-8200 fax back international@adtran.com TA 544 User Manual © 2001, ADTRAN, Inc.
ページ7に含まれる内容の要旨
TA 544 User Manual/61200704L1-1A Page 7 of 68 Customer Service, Product Support Information, and Training ADTRAN will replace or repair this product within 5 years from the date of shipment if the product does not meet its published specification, or if it fails while in service. A return material authorization (RMA) is required prior to returning equipment to ADTRAN. For service, RMA requests, training, or more information, see the toll- free contact numbers given below. Presales Inquiries and
ページ8に含まれる内容の要旨
TA 544 User Manual/61200704L1-1A Page 8 of 68 or possible fees associated with repair, contact CAPS directly at the following number: CAPS Department (256) 963-8722 Identify the RMA number clearly on the package (below address), and return to the following address: ADTRAN Customer and Product Service 901 Explorer Blvd. Huntsville, Alabama 35806 RMA # _____________ Training The Enterprise Network (EN) Technical Training offers training on our most popular products. These courses include overviews
ページ9に含まれる内容の要旨
TA 544 User Manual/61200704L1-1A Page 9 of 68 TA 544 SERIES IAD USER MANUAL This document is designed for use by network administrators and others who will configure and provision the Total Access®544. It contains overview information, information about navigating the VT 100 user interface, configuration information, and menu descriptions. CONTENTS TA 544Overview . ... .......... ... .......... ... ............. ... .......... ... .....13 Firmware Updates. .......... ... .......... ... .........
ページ10に含まれる内容の要旨
TA 544 User Manual/61200704L1-1A Page 10 of 68 Layer Two Protocol ...... ... .......... ... ............. ... .......... ... .....25 ATM Config .. .......... ... .......... ... ............. ... .......... ... .....25 ATM Stats ... .......... ... .......... ... ............. ... .......... ... .....26 DSL RateConfig .......................................................... 28 Configuring the Router –Configuration............................................ 29 Global ... ... .......... ... .....
ページ11に含まれる内容の要旨
TA 544 User Manual/61200704L1-1A Page 11 of 68 FIGURES Figure1. TA544Rear Panel.... ... .......... ... ............. ... .......... ... .... 13 Figure2. VoiceoverDSL ...... ... .......... ... ............. ... .......... ... .... 14 Figure3. System InformationMenu . .......... ... ............. ... .......... ... .... 16 Figure4. System ConfigurationMenu.......... ... ............. ... .......... ... .... 18 Figure5. System UtilityMenu... ... .......... ... ............. ... .......... ... ....
ページ12に含まれる内容の要旨
TA 544 User Manual/61200704L1-1A Page 12 of 68 TA 544 User Manual © 2001, ADTRAN, Inc.
ページ13に含まれる内容の要旨
TA 544 User Manual/61200704L1-1A Page 13 of 68 1. TA 544 OVERVIEW The Total Access 544 is a complete solution Integrated Access Device (IAD) for Voice over ATM (VoATM) appli- cations. The unit includes a modular network interface, Nx64 V.35 interface, 10/100BaseT interface, ISDN ports, and an optional battery back-up (1200641L1) for added security. The TA 544 can provision, test, and provide status for any of the voice and data interfaces. All connections are made via the rear panel (see Figure
ページ14に含まれる内容の要旨
HD-10 BRI Mux HD-10 BRI Mux HD-10 BRI Mux HD-10 BRI Mux QFC-C QFC-C QFC-C QFC-C T1-OR T1-OR T1-OR T1-OR 1181200L1 1181200L1 1181200L1 1181200L1 1181300L1 1181300L1 1181300L1 1181300L1 1181310L1 1181310L1 1181310L1 1181310L1 POWER POWER POWER POWER PWR PWR PWR PWR DSX DSX DSX DSX DSX DSX DSX DSX LBK LBK LBK LBK LBK LBK LBK LBK 1 1 1 1 LP LP LP LP 2 2 2 2 ALM ALM ALM ALM PWR PWR PWR PWR 3 3 3 3 + + + + 4 4 4 4 DSX #1 DSX #1 DSX #1 DSX #1 6V T R 6V T R 6V T R 6V T R 5 5 5 5 DSX #2 DSX #2 DSX #2 DSX
ページ15に含まれる内容の要旨
TA 544 User Manual/61200704L1-1A Page 15 of 68 5. INSTALLATION Unpack and Inspect the Unit After unpacking the unit, inspect it for possible shipping damage. If the equipment has been damaged in transit, im- mediately file a claim with the carrier, then contact ADTRAN Customer Service. Shipped by ADTRAN The following items are included in the ADTRAN shipment: The TA 544 DB-9adapter 6 ft. RJ-45 to RJ-45 cable 2 wall mount hinges 4 each 6-32 screws AC power cord CD containing User Man
ページ16に含まれる内容の要旨
TA 544 User Manual/61200704L1-1A Page 16 of 68 6. CONFIGURING THE TA 544 System Info The SYSTEM INFO menu provides basic information about the unit and contains data fields for editing information. Figure 3 displays the submenus available when you select this menu item. Figure 3. System Information Menu > System Name Provides a user-configurable text string for the name of the TA 544. This name can help you distinguish between dif- ferent installations. You can enter up to 40 alpha-numeric chara
ページ17に含まれる内容の要旨
TA 544 User Manual/61200704L1-1A Page 17 of 68 > Part Number ADTRAN part number for the product assembly. > Serial Number Serial number of the product assembly. > Firmware Revision Displays the current firmware revision level of the controller. > Bootcode Revision Displays the bootcode revision. > System Uptime Displays the length of time since the TA 544 system reboot. > Date/Time Displays the current date and time, including seconds. This field can be edited. Enter the time in 24-hour format (
ページ18に含まれる内容の要旨
TA 544 User Manual/61200704L1-1A Page 18 of 68 System Config Set up the TA 544 operational configuration from the SYSTEM CONFIG menu. Figure 4 shows the items included in this menu. Figure 4. System Configuration Menu > Operating Mode The operating mode is set automatically. > Network Timing Mode Selects the timing source for the entire system. The timing options available are listed below. Network The clock is recovered from the network (WAN interface). Internal The clock is generated internall
ページ19に含まれる内容の要旨
TA 544 User Manual/61200704L1-1A Page 19 of 68 Password When the authenticating method is password, this text string is used for the password. Idle Time (1-255) This sets the amount of time you can be idle before you are automatically logged off. Level This is the security level granted to the user. >SNMP Menu The TA 544 is an SNMP agent. It can respond to Gets and Sets, and can generate traps. These two lists set up the manager, communities, and levels. Access When set to OFF, SNMP access is de
ページ20に含まれる内容の要旨
TA 544 User Manual/61200704L1-1A Page 20 of 68 > Maint Port Menu The TA 544’s VT 100 CRAFT port can be accessed via an RJ-48 located on the rear panel. The setup for these ports is under this menu. Password Protect When set to OFF, the maintenance port is not password protected. When ON (def), the TA 544 will prompt for a password upon startup. Password This is the text string that is used for comparison when password protecting the maintenance port. By default, no password is entered. If you fo