ページ1に含まれる内容の要旨
PCL-849
4-Port RS-232
Interface Card
ページ2に含まれる内容の要旨
Copyright Notice This documentation and the software included with this product are copyrighted 2001 by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd. reserves the right to make improvements to the products described in this manual at any time without notice. No part of this manual or software may be reproduced, copied, translated or transmitted, in any form or by any means without the prior written permission of Advantech Co., Ltd. Information provid- ed in this manual is inte
ページ3に含まれる内容の要旨
Contents Chapter 1: Introduction ....................................................... 5 Description ............................................................................. 6 Features .................................................................................. 7 Specifications ......................................................................... 7 Chapter 2: Hardware Installation ....................................... 11 Initial Inspection .....................................
ページ4に含まれる内容の要旨
1 Introduction CHAPTER
ページ5に含まれる内容の要旨
Description The PCL-849 series are four port serial communication interface cards. Each port can be configured individually to RS-232 using on- board jumpers. PCL-849A/849B serial ports are implemented using 16C554 UARTs which make serial I/O more reliable. For higher performance, 16C654 UARTs can be installed in place of the 16C554 to create the PCL- 849+. By buffering data into 64-byte packets before putting it on the bus, UARTs drastically reduce the CPU load. This makes the PCL-849+ especial
ページ6に含まれる内容の要旨
Features v Four independent RS-232 serial ports v Transmission speeds up to 307.2 kbps v Independent I/O addresses and independent/shared IRQ settings for each of 4 serial ports v Wide IRQ selection: 3, 4, 5, 6, 7, 9, 10, 11, 12, 15 v Supports Standard DOS COM1, COM2, COM3, and COM4 v Supports DOS/Windows 3.1, Windows 95/98, Windows NT (ICOM Utility) v Supports surge protection: 3000 V (PCL-849B/849+) DC v LED indicators on each port indicate data flow v On-board interrupt status register for gr
ページ7に含まれる内容の要旨
· UART: 1 × 16C554 (PCL-849A/849B) 1 × 16C654 (PCL-849+) · Speed: 50 ~ 921.6 kbps (PCL-849A) 50 ~ 307.2 kbps (PCL-849B/849+) · Connectors: 30-cm male DB-37 to 4 × DB25 male (DTE) · Data signals: TxD, RxD, RTS, CTS, DTR, DSR, DCD, RI, GND · Surge protection: 3000 V (PCL-849B/849+) DC · Power requirement: 250 mA typical 500 mA max. (+5 V), 70 mA typical. 120 mA max.(±12 V), · Dimensions: 185 mm × 98 mm · Operating Temperature.: 0 ~ 60° C (32 ~ 140° F) (refer to IEC-68- 1.2.3 item) · Storage
ページ8に含まれる内容の要旨
Chapter 1 Introduction 9 Figure 1-1: Switch and jumper layout
ページ9に含まれる内容の要旨
10 PCL-849 User's Manual
ページ10に含まれる内容の要旨
2 Hardware Installation CHAPTER
ページ11に含まれる内容の要旨
Initial Inspection Depending on the option you ordered, in addition to this manual, you should find the following items inside the shipping container: • PCL-849(A/B/+) 4-port RS-232 Card • One 30-cm male DB-37 to four male DB-25 cable • One diskette with ICOM utility software We have carefully inspected the PCL-849 mechanically and electrical- ly before shipping. It should be free of marks and scratches and in perfect working order on receipt. As you unpack the PCL-849, check it for signs of shi
ページ12に含まれる内容の要旨
Card Installation Warning! Turn off your PC’s power supply whenever you install or remove the PCL-849 or its cables. Static electricity can easily damage computer equipment. Ground yourself by touching the chassis of the computer (metal) before you touch any boards. 1. Turn off the computer. Turn the power off to any peripheral devices (such as printers and monitors). 2. Disconnect the power cord and any other cables from the back of the computer. Turn the PC if necessary to gain access to the c
ページ13に含まれる内容の要旨
Card Configuration Each port on the PCL-849 card has a jumper and a DIP switch which require configuring prior to use. The DIP switch sets the port to the appropriate I/O address and speed mode. The jumpers set the port's IRQ. Default Settings The board is shipped with default settings. If you need to change these settings, however, see the following sections. Otherwise, you can simply install the card. Note that you will need to disable your CPU card's on-board COM ports, if any, or set th
ページ14に含まれる内容の要旨
Standard Mode In this mode, each of the four ports is assigned an address, as shown below. Port 1 Ch1 base address 3F8 Port 2 Ch2 base address 2F8 Port 3 Ch3 base address 3E8 Port 4 Ch4 base address 2E8 Enhanced Mode In this mode, the address for each of the four ports is assigned according to the card base address, which is set using switch S2. Select an address which is not already in use by another card in the system. If you are installing more than one PCL-849 card in your system, set the c
ページ15に含まれる内容の要旨
Default Settings Mode Enhanced Mode Port 1 IRQ12 Address 300H Port 2 IRQ12 Address 308H Port 3 IRQ12 Address 310H Port 4 IRQ12 Address 318H The following example shows how to set the base address to 2F8. The switch sum is set to 2F8: 200 + 80 + 40 + 20 + 10 + 8 (HEX). Note: On the PCL-849 address line A9 does not appear on the DIP switch, as it is permanently hardwired to hex 200. Interrupt Level (IRQ) Setting (S1, JP1, JP2, JP3, JP4) The card's IRQ mode can be set using S1. Shared IRQ mode o
ページ16に含まれる内容の要旨
Independent IRQ Mode (JP1-JP4) In this mode, the IRQ level for each of the four ports is set individual- ly. For each port, select an IRQ which is not already in use by another card in the system. The correspondence of jumpers to ports is shown below. Port 1 à JP1 Port 2 à JP2 Port 3 à JP3 Port 4 à JP4 Shared IRQ Mode (JP1) Select an IRQ which is not already in use by another card in the system. If you are installing more than one PCL-849, set them to different IRQ numbers. Jumper Bank JP1 c
ページ17に含まれる内容の要旨
switch S1 designates the card's interrupt status register address, as shown in the following figure and table. Interrupt Status Register S1 Bit Function 0 Port 1 1 Port 2 2 Port 3 3 Port 4 4 Not Used 5 Not Used 6 Not Used 7 Not Used The user may change the interrupt status register address via S1. Please note that the address decoder will occupy a continuous, 16-byte area related to the switch setting. For example, if you set the switch to 210H, then the address 210H to 21FH will all be decoded
ページ18に含まれる内容の要旨
Table 2-1: DIP switch settings for S1 Interrupt A4 A5 A6 A7 A8 Register ON ON ON ON ON 200H OFF ON ON ON ON 210H ON OFF ON ON ON 220H OFF OFF ON ON ON 230H ON ON OFF ON ON 240H OFF ON OFF ON ON 250H ON OFF OFF ON ON 260H OFF OFF OFF ON ON 270H ON ON ON OFF ON 280H OFF ON ON OFF ON 290H ON OFF ON OFF ON 2A0H OFF OFF ON OFF ON 2B0H ON ON OFF OFF ON 2C0H OFF ON OFF OFF ON 2D0H ON OFF OFF OFF ON 2E0H OFF OFF OFF OFF ON 2F0H ON ON ON ON OFF 300H OFF ON ON ON OFF 310H ON OFF ON ON OFF 320H OFF OFF ON
ページ19に含まれる内容の要旨
Speed Mode selection The PCL-849 employs a unique speed option that allows the user to choose either normal speed mode (1x) or high speed mode (8x). This high speed mode is selected at S2. Normal Speed Mode To select the baud rate commonly associated with COM ports , such as 2400, 4800, 9600. . .115.2 kbps, place the switch as follows. High Speed Mode To increase normal mode rates by eight times, (e.g. if 115.2 kbps is selected, the rate is increased to 921.6 kbps), place the switch as follows
ページ20に含まれる内容の要旨
3 Software Installation CHAPTER