ページ1に含まれる内容の要旨
CAMPUS-REX2 RS INTERFACE CARD
VERSION 5.1
USER MANUAL
ページ2に含まれる内容の要旨
Copyright July 2003 © 2003 ADC Telecommunications, Inc. All rights reserved. Trademark Information ADC and ADC Telecommunications are registered trademarks of ADC Telecommunications, Inc. StarGazer, Campus-Star, and Campus-REX are registered trademarks of ADC Telecommunications, Inc No right, license, or interest to such trademarks is granted hereunder, and you agree that you shall assert no such right, license, or interest with respect to such trademarks. All other product names mentioned
ページ3に含まれる内容の要旨
FCC Notice FCC NOTICE This unit complies with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will n
ページ4に含まれる内容の要旨
Using This Manual USING THIS MANUAL This manual provides installation, configuration and management procedures ® ® for using the ADC Campus Remote Ethernet eXpress2 (Campus-REX2 ) RS interface card. It includes procedures to: ™ install the card in either a Campus-RS desktop unit (150-1158-01, ® 150-1158-02, 150-1158-51, or 150-1158-52) or Campus-Star chassis (150-1220-01, 150-1220-02, or 150-1220-51) configure the Campus-REX2 using the LCD and buttons configure the Campus-REX2 using th
ページ5に含まれる内容の要旨
Document Conventions The following conventions are used in this manual: This font indicates text that appears on the LCD or terminal. Keycaps, such as ESC , indicate keys that you press on a terminal keyboard. Names in bold font indicate buttons on the desktop unit or line unit that you press. For a list of abbreviations used in this manual, see “Abbreviations” on page 143. This table describes the manuals and guides in the Campus-RS documentation set. Document Description Campus-Star
ページ6に含まれる内容の要旨
Unpack and Inspect the Shipment UNPACK AND INSPECT THE SHIPMENT Upon receiving the Campus-REX2 RS Interface Card: 1 Unpack the card and inspect it for signs of damage. If it has been damaged in transit, report the extent of the damage to the transportation company and to your sales representative immediately. Order replacement equipment if necessary. 2 Compare the contents of the package against the packing list to ensure a complete and accurate shipment. If the shipment is incomplete or i
ページ7に含まれる内容の要旨
Table of Contents TABLE OF CONTENTS Chapter 1: Installing and Accessing the REX2 ____________ 1 Installing the Campus-REX2.................................................................. 2 Installing into a Desktop Unit.................................................. 3 Installing into a Campus-Star Chassis ..................................... 4 Connecting the Ethernet Line................................................................. 5 Powering Up and Checking the Connection ..........
ページ8に含まれる内容の要旨
Table of Contents Configuring the Campus-REX2 as a Bridge.........................................30 Configuring Bridge Protocol, Encapsulation and Timing......31 Configuring Bridge Features ..................................................32 Saving the Bridge Configuration............................................40 Accessing the Bridge and ARP Tables...................................41 Configuring the Campus-REX2 as a Router.........................................44 Configuring Routing P
ページ9に含まれる内容の要旨
Table of Contents Viewing 24-Hour Performance History................................. 76 Viewing Seven-Day Performance History............................. 77 Viewing Local Alarm History ............................................... 79 Viewing Ethernet Statistics .................................................................. 80 Viewing Bridge Statistics ...................................................... 81 Viewing Router Statistics ....................................................
ページ10に含まれる内容の要旨
Table of Contents Local Alarms ........................................................................111 Remote Alarms.....................................................................112 Configuring Loopbacks ......................................................................113 Initiating a Loopback............................................................114 Clearing a Loopback ............................................................114 Setting the Loopback Timeout ............
ページ11に含まれる内容の要旨
Table of Contents Telnet ................................................................................... 133 FTP....................................................................................... 133 MIB and Trap Support ....................................................................... 133 DHCP ................................................................................................. 134 Encapsulation Protocols ...............................................................
ページ12に含まれる内容の要旨
Table of Contents xii Campus-REX2 RS Interface Card User Manual
ページ13に含まれる内容の要旨
INSTALLING AND ACCESSING THE REX2 1 The Campus-REX2 RS is a 10/100Base-T Ethernet interface card that provides: IEEE 802.1d transparent MAC level bridging with Spanning Tree protocol support static and dynamic IP Routing DHCP relay DHCP client cHDLC or PPP frame encapsulation options FTP server for transferring software upgrades VLAN support that accommodates forwarding larger-sized packets embedded Simple Network Management Protocol Version 1 (SNMP V1) agent The following sec
ページ14に含まれる内容の要旨
Chapter 1 - Installing and Accessing the REX2 The Campus-REX2 can be installed into either a Campus-Star chassis (paired with a Campus-RS or -HRS Line Unit) or into a Campus-RS or -HRS desktop unit. The , installed into either, provides one end of a High-bit-rate Digital Subscriber Line (HDSL) transmission system. When connected to another Campus-RS, Campus-HRS, Campus-T1®, Campus-768®, or Campus-E1® desktop unit or a line unit in another chassis, the Campus system transports digitized vo
ページ15に含まれる内容の要旨
120 VAC@60Hz or 220 VAC@50Hz .2A Max 10 Base-T Link/Activity 100 Base-Tx CONSOLE CAMPUS-RS LINE MDI MDI-X PC HUB REX2 Router Chapter 1 - Installing and Accessing the REX2 Installing into a Desktop Unit Install the Campus-REX2 interface card into a Campus-RS or Campus-HRS desktop unit before you install the desktop unit (install power and HDSL cables). Install the Campus-RS desktop unit using the instructions in the Campus-RS Desktop Unit User Manual. Ensure power is off to the desktop unit b
ページ16に含まれる内容の要旨
Chapter 1 - Installing and Accessing the REX2 Installing into a Campus-Star Chassis The Campus-REX2 must be installed into a Campus-Star chassis first, before you install the corresponding Campus-RS or Campus-HRS line unit. The Campus-REX2 is not hot-swappable. Damage may occur to the Campus-REX2, the line unit, or both if the line unit is installed before you install the Campus-REX2. 1 Ensure that a line unit is not installed in the line-unit slot corresponding to the slot where you will i
ページ17に含まれる内容の要旨
Chapter 1 - Installing and Accessing the REX2 3 Gently press the card into place until it is seated firmly in the mating connector. 4 Secure the card in place using the two captive screws. 5 Install a Campus-RS line unit and connect it to an HDSL line using the Campus-RS Line Unit User Manual. The line unit provides the DSL connection for the interface card. CONNECTING THE ETHERNET LINE The 10 Base-T and 100 Base-Tx (10/100Base-T) port on the rear panel of the Campus-REX2 connects to a LAN
ページ18に含まれる内容の要旨
120 VAC@60Hz or 220 VAC@50Hz .2A Max MDI MDI-X HUB PC REX2 Router 10 Base-T Link/Activity 100 Base-Tx Chapter 1 - Installing and Accessing the REX2 2 Plug one end of the Category 5 cable into the 10/100Base-T connector on the Campus-REX2 faceplate. Campus-RS Desktop Unit PC, hub, router or other Ethernet equipment Ethernet port 10 Base-T 100 Base-Tx port Category 5 cable The Campus-REX2 10/100Base-T interface operates in either half- or full-duplex mode which is determined by autosensing its
ページ19に含まれる内容の要旨
Chapter 1 - Installing and Accessing the REX2 POWERING UP AND CHECKING THE CONNECTION Verify operating status after completing a full installation that includes installing of the Campus-REX2 into a desktop unit or Campus-Star chassis and then completing the installation of the desktop unit or the Campus-Star chassis (including the Line Unit): 1 Verify that the power cord is connected to the desktop unit or to the Campus-Star chassis (if you have an AC power supply) and to an external power
ページ20に含まれる内容の要旨
Chapter 1 - Installing and Accessing the REX2 SETTING UP ACCESS TO THE CAMPUS UNIT Configure a Campus system through any of the following: a PC connected to the desktop unit Console port a PC connected to the Campus-Star line unit Console port a telnet session to the Campus-REX2 over the Internet or the CMU in a Campus-Star chassis the LCD menu and buttons on the desktop unit or CMU front panel StarGazer or a comparable EMS using SNMP A Console port or telnet connection provides acce