ページ1に含まれる内容の要旨
User Manual
EUROPOWER PMP2000
800-Watt 14-Channel Powered Mixer with Multi-FX Processor
behringer.com
ページ2に含まれる内容の要旨
2 EUROPOWER PMP2000 User Manual Table of Contents Thank you ....................................................................... 2 Important Safety Instructions ...................................... 3 Legal Disclaimer ............................................................. 3 Limited Warranty ........................................................... 3 1. Introduction ............................................................... 6 1.1 Before you get started ........................
ページ3に含まれる内容の要旨
3 EUROPOWER PMP2000 User Manual 9. Do not defeat the safety purpose of the polarized Limited Warranty Limited Warranty Important Safety Important Safety or grounding-type plug. A polarized plug has two blades Instructions Instructions § 1 Warranty with one wider than the other. A grounding-type plug [1] This limited warranty is valid only if you purchased has two blades and a third grounding prong. The wide the product from a BEHRINGER authorized dealer in the blade or the third prong are
ページ4に含まれる内容の要旨
4 EUROPOWER PMP2000 User Manual [2] Subsequently, the product must be returned in [7] Any repair or opening of the unit carried out by § 9 Amendment its original shipping carton, together with the return unauthorized personnel (user included) will void the Warranty service conditions are subject to change without authorization number to the address indicated by limited warranty. notice. For the latest warranty terms and conditions MUSIC Group. [8] If an inspection of the product by MUSI
ページ5に含まれる内容の要旨
5 EUROPOWER PMP2000 User Manual [29] [30] [31] Main Section [1] [11] [32] [2] Stereo line input [3] [20] [4] [18] [5] [17] [19] [12] [6] [15] [13] [7] [16] [24] [14] [21] [9] [22] Tape inputs/outputs & phantom power switch [23] [10] Mono channel [25] [26] [27] [28] [33] [34] [39] [35] Rear panel connectors [36] [37] [38] behringer.com [8]
ページ6に含まれる内容の要旨
6 EUROPOWER PMP2000 User Manual 1. Introduction 1.1.3 Online registration BEHRINGER is a company with its roots in professional recording studio Please register your new BEHRINGER equipment right after your purchase technology. For many years now we have been successful in developing products by visiting http://behringer.com and read the terms and conditions of our for studio and live use. These include microphones and 19" devices of all kinds warranty carefully. (compressors, enhancers, no
ページ7に含まれる内容の要旨
7 EUROPOWER PMP2000 User Manual [12] The CD/TAPE/LINE IN RCA input of channel 13/14 allows you to feed in [30] This is the LED level meter of the effects processor. Please make sure external stereo signals from your CD player or tape deck, for example. that the clip LED lights up with signal peaks only. If it is lit constantly, this indicates that the effects processor is overdriven, which can lead to [13] The CD/TAPE/LINE OUT RCA output provides the stereo main mix signal of unpleasant d
ページ8に含まれる内容の要旨
8 EUROPOWER PMP2000 User Manual 3. Effects Processor Balanced ¼" TRS connector 24-Bit Multi-Effects Processor strain relief clamp This built-in effects module produces high-grade standard effects such as reverb, chorus, flanger, delay and various combination effects. The integrated sleeve effects module has the advantage of requiring no wiring. This way, the danger ring of creating ground loops or uneven signal levels is eliminated at the outset, tip completely simplifying the handling. The
ページ9に含まれる内容の要旨
9 EUROPOWER PMP2000 User Manual LEFT/MONITOR RIGHT MONO MAIN ¼" TS footswitch connector +1 +1 strain relief clamp sleeve tip -1 -1 16 Ω 16 Ω 8 Ω 8 Ω 4 Ω 4 Ω sleeve BRIDGE pole 1/ground +1 16 Ω 8 Ω tip pole 2 +2 The footswitch connects both poles momentarily Fig. 4.6: PMP2000 loudspeaker connector assignment Fig. 4.4: ¼" TS connector for footswitch 5. Wiring Examples 4.4 Loudspeaker connections Your EUROPOWER is equipped with high-quality Neutrik Speakon-compatible Loudspeaker connection (FOH
ページ10に含まれる内容の要旨
10 EUROPOWER PMP2000 User Manual EUROPOWER PMP2000 Loudspeaker connection enabling both mono FOH and mono monitor mixes PMP2000 rear panel (part view) Stereo channel 7/8 Tape in/out Mono Mono channel 6 channels 1 - 4 Mono channel 5 DAT recorder Vocal Electric microphones guitar V-AMP 3 2 x BEHRINGER 2 x BEHRINGER EUROLIVE B1520 (passive) EUROLIVE F1520 (passive) Electric bass Fig. 5.2: PMP2000 as double mono amplifier (example) Keyboard ◊ For this application, however, please set the MODE sw
ページ11に含まれる内容の要旨
11 EUROPOWER PMP2000 User Manual 6. Specifications Mono Inputs Monitor Output Microphone inputs Type ¼" TRS connector, unbalanced Type XLR, electronically balanced, Impedance 1.5 kΩ discrete input circuit Max. output level +21 dBu Mic E.I.N. (20 Hz - 20 kHz) DSP 24-bit Texas Instruments @ 0 Ω source resistance -122 dB / 125 dB A-weighted Converter 24-bit Sigma-Delta, @ 50 Ω source resistance -122 dB / 125 dB A-weighted 64/128-times oversampling @ 150 Ω source resistance -121 dB / 124 dB A-we
ページ12に含まれる内容の要旨
12 EUROPOWER PMP2000 User Manual Power Supply Voltage and fuse USA/Canada 120 V~, 60 Hz T 10 A H 250 V Europe/U.K./Australia 2 30 V~, 50 Hz T 5 A H 250 V China/Korea 2 20 V~, 50/60 Hz T 6.3 A H 250 V Japan 1 00 V~, 50 – 60 Hz T 12 A H 250 V General export model 2 30 V~, 50 Hz T 5 A H 250 V 120 V~, 60 Hz T 10 A H 250 V Power consumption max. 1 kW Mains connection Standard IEC receptacle Dimensions/Weight Dimensions (H x W x D) approx. 11 x 18 1/ 8 x 10 5/ 8" approx. 280 x 460 x 270 m
ページ13に含まれる内容の要旨
13 EUROPOWER PMP2000 User Manual FEDERAL COMMUNICATIONS COMMISSION COMPLIANCE INFORMATION EUROPOWER PMP2000 Responsible party name: MUSIC Group Services USA, Inc. Address: 18912 North Creek Parkway, Suite 200 Bothell, WA 98011, USA Phone/Fax No.: Phone: +1 425 672 0816 Fax: +1 425 673 7647 EUROPOWER PMP518M complies with the FCC rules as mentioned in the following paragraph: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15
ページ14に含まれる内容の要旨
behringer.com