ページ1に含まれる内容の要旨
O O O Op p p pe e e er r r ra a a at t t tiiiin n n ng g g g M M M Ma a a an n n nu u u ua a a allll 3 3 3 30 0 0 01 1 1 11 1 1 1
Digital indicator 3011
Operating Manual Digital Indicator 3011 Version V0.1 Stand: 06.09.07 Page 1 of 8
Subject to technical modifications. Drafts are protected according to §823 BGB: Copy, duplication or circulation only with explicit approval.
S S S So o o oe e e eh h h hn n n nl ll le e e e P P P Pr r r ro o o of f f fe e e es s
ページ2に含まれる内容の要旨
O O O Op p p pe e e er r r ra a a at t t tiiiin n n ng g g g M M M Ma a a an n n nu u u ua a a allll 3 3 3 30 0 0 01 1 1 11 1 1 1 Table of content ELECTRONIC NAMEPLATE TYPE 3011 .............................................................................. 3 FOR NON-APPROVABLE SCALES, “D“ INSTEAD OF “E“ IS INDICATED. SWITCH ON/OFF TYPE 3011 ............................................................................................................... 3 SWITCH ON/OFF TYPE 3011
ページ3に含まれる内容の要旨
O O O Op p p pe e e er r r ra a a at t t tiiiin n n ng g g g M M M Ma a a an n n nu u u ua a a allll 3 3 3 30 0 0 01 1 1 11 1 1 1 Electronic nameplate type 3011 By pressing the keys and , the electronic nameplate is indicated. T • With the arrow keys ( ), the electronic nameplate as well as the T F serial number and calibration counter of the measuring point can be indicated on the display.
ページ4に含まれる内容の要旨
O O O Op p p pe e e er r r ra a a at t t tiiiin n n ng g g g M M M Ma a a an n n nu u u ua a a allll 3 3 3 30 0 0 01 1 1 11 1 1 1 SWITCH On/Off Type 3011 • Switch the indicator on/off via the ON/OFF key. • While switching on, the scale is zeroed. If the scale is switched on outside the zero range at power-on, the scale indicates an error message: _0_ = Measuring value below zero limit _ _ 0 = Measuring value above zero limit The application is switched off to av
ページ5に含まれる内容の要旨
O O O Op p p pe e e er r r ra a a at t t tiiiin n n ng g g g M M M Ma a a an n n nu u u ua a a allll 3 3 3 30 0 0 01 1 1 11 1 1 1 Zeroing Type 3011 • Zeroing via the zero key. • Zeroing approvable: -1 to +3% according to Approval Directive. • Zero range non-approvable: Same range as set zero range limits at power-on. • The display indicates after keypress • at <-1% message Err 5 • at > 3% message Err 5 • Zero tracking: in the setting mode, the zero tra
ページ6に含まれる内容の要旨
O O O Op p p pe e e er r r ra a a at t t tiiiin n n ng g g g M M M Ma a a an n n nu u u ua a a allll 3 3 3 30 0 0 01 1 1 11 1 1 1 Tara functions Type 3011 • The following tare function is available as standard fort he indicator 3011 to save weighing data in the tare memory: 1. Manual tare • Keypad management: • Manual tare: Via the key "Tara" on the membrane keyboard. T • Manual tare: by pressing the tare key. The tare value is saved, the weight indicat
ページ7に含まれる内容の要旨
O O O Op p p pe e e er r r ra a a at t t tiiiin n n ng g g g M M M Ma a a an n n nu u u ua a a allll 3 3 3 30 0 0 01 1 1 11 1 1 1 X10 DISPLAY Type 3011 • The tenfold higher resolution on the display is activated by pressing the keys “PRINT” and “-0-“. • If the scale is calibrated approvable, the tenfold higher resolution is indicated after a keypress for 5 seconds or as long as the keys are hold. Operating Manual Digital Indicator 3011 Version V0.1 Stand: 06.09.0
ページ8に含まれる内容の要旨
O O O Op p p pe e e er r r ra a a at t t tiiiin n n ng g g g M M M Ma a a an n n nu u u ua a a allll 3 3 3 30 0 0 01 1 1 11 1 1 1 PRINT Type 3011 • An optional interface RS232 must be assembled in the digital indicator 3011 for the function „Print“. • The stored print template is send via the interface by pressing the print key. Print template design and print conditions are realised via the service program. Operating Manual Digital Indicator 3011 Version V0.