36C
Cycle Pilot Gas Valve
INSTALLATION INSTRUCTIONS
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
The 36C cycle pilot gas valves with redundant pilot sole-
noid main gas regulator, integral gas pressure switch and
electrical connection on the gas valve for mercury flame
sensor connection.
SPECIFICATIONS
1
Electrical Rating: 0.6 amps Maximum Pressure Rating: /2 PSI (14.0” W.C.)
15
ページ2に含まれる内容の要旨
PRECAUTIONS DO NOT BEGIN INSTALLATION UNTIL YOU READ THE FOLLOWING PRECAUTIONS. If you do not follow these instructions exactly, a fire or explosion ! WARNING may result causing property damage, personal injury or loss of life. 1. Failure to turn off electric or main gas supply to heating system could cause personal injury and/or property damage by shock, gas suffocation, fire, and/or explosion. 2. Do not use this control on circuits exceeding specified voltage. Higher voltage will damage the c
ページ3に含まれる内容の要旨
INSTALLATION Pilot gas PRESS PILOT GAS CONNECTION outlet PILOT Install fitting into pilot gas outlet (see figure 3), turning until finger-tight. Insert clean, deburred tubing all the way through the TAP fitting. While holding the tubing securely, slowly tighten fitting until you feel a slight "give". Tighten the fitting an additional 1½ turns. Gas outlet Figure 3 SYSTEM WIRING NOTE REFER TO AND FOLLOW THE APPLIANCE MANUFACT- All wiring should be installed in accordance with local and URER'S
ページ4に含まれる内容の要旨
COM. L S INSTALLATION (cont'd) Wiring for 36C84-912, -921 & 36C94-906 Gas Valves Figure 5 TAN 3 Cycle pilot plug-in REDUNDANT COIL 42 MAIN PILOT BLACK PRESSURE RELAY ADJ. SWITCH COIL WHITE S L TAN COMMON TAN 36C84 GAS VALVE 3098 MERCURY FLAME SENSOR MAIN VALVE RELAY COIL HOT 2 C LIMIT THERMOSTAT LINE 24 VAC PILOT SOLENOID COLD 3 COIL PRESSURE L N.O. 5059 PILOT RELIGHT CONTROL 4 COMMON SWITCH SILVER 6 BRASS 5 NOTE: On systems where one side of the low voltage transformer is grounded, silver termi
ページ5に含まれる内容の要旨
COM. L S INSTALLATION (cont'd) Figure 7 Wiring for 36C84-913 Gas Valve SURE-START TERMINALS CS 36C84 GAS VALVE 3098 MERCURY FLAME SENSOR MAIN VALVE RELAY HOT 2 4 3 PILOT/REDUNDANT PRESSURE COLD SOLENOID VALVE SWITCH N.O. WIRING HARNESS 5-WIRE PLUG 1 3 4 2 5 BLUE RED TAN YELLOW ORANGE DIODE RESISTOR SCR DIODE C PILOT A G ADJ. FUSE OR SAFETY TIMER FUSE RESISTOR WARP SWITCH CONTACTS (N.C.) WARP SWITCH RESISTOR HEATER SPARK CIRCUIT 6 5 50A22 RELIGHT/SAFETY TIMER 24 VAC THERMOSTAT LINE Figure 8 Wiri
ページ6に含まれる内容の要旨
COM. L S INSTALLATION (cont'd) Wiring for 36C84-923 Gas Valve Figure 9 PILOT ADJ. 36C84 GAS VALVE 3098 MERCURY FLAME SENSOR MAIN VALVE RELAY COIL HOT 2 C LIMIT THERMOSTAT LINE 24 VAC PILOT SOLENOID COLD 3 COIL PRESSURE L N.O. 5059 PILOT RELIGHT CONTROL 4 COMMON SWITCH SILVER 6 BRASS 5 NOTE: On systems where one side of the low voltage transformer is grounded, silver terminal (6) of the 5059 must be connected to ground side. TO ELECTRODE 6
ページ7に含まれる内容の要旨
INSTALLATION (cont'd) OUTLET PRESSURE ADJUSTMENTS Conversion Outlet Pressure from Pilot Gas Regulator This control is shipped from the factory with the regulator set Model Natural/LP Adjustment Adjustment to the outlet pressure shown in the table on page 1. Consult 36C84-912 See Conversion See Fig. 10 See Fig. 10 the appliance rating plate to be sure that the setting matches from Natural Gas the appliance manufacturer's specifications. If required, the to L.P. regulator can be adjusted for out
ページ8に含まれる内容の要旨
PARTS & ACCESSORIES Item Model Item Model Number Number Description Number Number Description F92-0656 L.P . to natural gas conversion kit F6-1794 Bracket for Bryant pilots when ® for 36C, 36D, 36E and 36F gas retrofitting with Cycle-Pilot . valves with regulation range of 2.5 to 5” W.C. F67-0918 Resistor assembly for use with 36C Cycle-Pilot gas valves with pressure F92-0659 Natural to regulated L.P . gas switch (NATURAL GAS conversion kit for 36C, 36D, 36E APPLICATIONS ONLY) 3098 and 36F gas v