Table of Contents Introduction 3 Standard Package Contents 4 Installation 5 Before you begin 6 UV (Ultraviolet) Sensor 6 Thermo-Hygrometer Sensor 9 Rain Gauge 11 Anemometer (wind sensor) 13 Main Unit 15 Battery installation 16 Buttons and Controls 17 Navigating through the modes 19 Customizing your Weather Station 22 LED Backlight Options 23 Connecting the Weather Station to a PC 23 Using Different Weather Modes 23 Pressure and Weather Forecast Mode 23 UV Mode 26 Clock and
ページ3に含まれる内容の要旨
Introduction Thank you for selecting the Honeywell Professional Weather Station with remote control. This compact and easy-to-use product features a wide variety of time and weather data, such as precise atomic time, perpetual calendar, air temperature, relative humidity, barometric pressure, wind speed and direction, rainfall, UV levels and etc. In this package you will find: One Main Unit (receiver) (TE923WD) One IR Remote Control (TS607) One Rain Gauge (remote rain sensor/transmit
ページ4に含まれる内容の要旨
Standard Package Contents Picture Components Main Unit Remote Control AC/DC 7.5V power adaptor UV Sensor consists of: Sensor Unit U-Shaped Sensor holder Circular Ground Stand Stake Base Wall-Mounting Base Thermo Hygrometer Sensor Rain Gauge consists of: Funnel shaped top with battery compartment Rain Gauge bucket Bucket see-saw mechanism Protective screen Anemometer consists of: Wind Cups Wind Vane Anemometer arm Anemometer base PC Software 4
ページ5に含まれる内容の要旨
4 screws for securing rain gauge to the flat surface; Mounting hardware 4 screws for securing anemometer to vertical surface 2m (6ft) USB cable PC connection cable Installation The Honeywell Professional Weather Station TE923W operates at 433MHz radio frequency, so no wire installation is required between the main unit (receiver) and the remote weather sensors (transmitters). The remote weather sensors include a thermo-hygrometer (temperature and humidity) sensor, UV (ultraviol
ページ6に含まれる内容の要旨
Before you begin • We recommend using alkaline batteries for the remote weather sensors and the main unit when temperatures are above 32°F (0°C). We recommend using lithium batteries for the remote weather sensors when temperatures are below 32°F (0°C). • Avoid using rechargeable batteries. (Rechargeable batteries cannot maintain correct power requirements). • ALWAYS install batteries in the remote weather sensors before the main unit. • Insert batteries before first use, matching th
ページ7に含まれる内容の要旨
UV (Ultraviolet) Sensor FEATURES • Ultraviolet light levels measurement • Remote UV levels data transmission to the main unit via 433MHz signal • 328 feet (100 meters) transmission range • Low battery indicator • Three different placement options – ground, stake and wall A B G F C E D A. LED INDICATOR • Flashes once when the remote sensor transmits a reading to the main unit • Flashes twice when battery power is low B. BATTERY COMPARTMENT SCREW Holds battery compartment d
ページ8に含まれる内容の要旨
Assembly • Snap the U-shaped sensor holder onto the UV sensor unit side grooves • Insert the round end of the U-shaped holder into one of the mounting hardware pieces provided Battery installation • Unscrew the lid on top of the UV sensor unit. • Remove the screw from the battery compartment door with a small Phillips screwdriver • Insert two 2 “AA” size 1.5V batteries (not included) matching the polarities shown in the battery compartment. • Replace the battery compartment door
ページ9に含まれる内容の要旨
Thermo-Hygrometer Sensor FEATURES • Remote data transmission to the main unit via 433 MHz signal • 328 feet (100 meters) transmission range without interference • LCD display of measured temperature and humidity • Five (5) transmission channels selection • Case can be wall mounted using built-in hanger A. LED INDICATOR • Flashes once when the remote sensor transmits a reading to the main unit. • Flashes twice when battery power is low. B. BATTERY COMPARTMENT Holds two AA-size b
ページ10に含まれる内容の要旨
• The remote thermo-hygrometer sensor can be placed on the flat surface or mounted on the wall in vertical position • Use the wall mount hardware and screws provided when mounting the thermo-hygrometer sensor on the wall Placement tips: • The remote thermo-hygrometer sensor should be placed in the area with a free air circulation and sheltered from the direct sunlight and an extreme weather conditions. • Ideally, place the thermo-hygrometer sensor above the natural surfaces (such a
ページ11に含まれる内容の要旨
Rain Gauge FEATURES • Precipitation measurement • Remote rainfall data transmission to the main unit via 433 MHz signal • 100 feet (30 meters) transmission range without interference • Built-in installation level • Non-corrosive protective screen B A C A. Rain gauge bucket Holds all rain gauge components B. Knob Secures the top on the rain gauge bucket C. Rain gauge bucket feet Allows securing the rain gauge on its place G D E H F I D. Funnel-shaped top with battery
ページ12に含まれる内容の要旨
G. Built-in leveler Allows leveling rain gauge on the surface H. Bucket see-saw mechanism Collects the rainfall in one of its containers and self-empties once full I. Protective screen Protects the rain gauge funnel from debris Battery installation • Unlock the funnel-shaped top on the rain gauge by turning both knobs on the sides in an anti-clockwise direction. • Remove the funnel-shaped top lifting it off the rain gauge bucket. • Remove 7 small screws from the battery compartme
ページ13に含まれる内容の要旨
Anemometer (wind sensor) FEATURES • Wind speed and wind direction measurement • Remote wind speed and wind direction data transmission to the main unit via 433 MHz signal • Operating range 100 feet (30 meters) • Wall or pole mount A B D C A. WIND VANE Measures wind direction B. WIND CUPS Measures wind speed C. ANEMOMETER BASE • Holds battery compartment • Allows mounting the anemometer vertically D. ANEMOMETER ARM Keeps anemometer assembly together E G F H 13
ページ14に含まれる内容の要旨
E. WIND CUPS SHAFT Holds wind cups on the anemometer arm F. BATTERY COMPARTMENT Holds 2 AA-size batteries G. WALL MOUNT SCREW OPENINGS Allows securing the anemometer in place H. BATTERY COVER Allows securing 2 AA size batteries on the anemometer base Assembly • Place the wind cups over the wind cups shaft of the anemometer arm • Insert the wrench tool provided into the wind cups opening and tighten the small screw inside. • Test if the wind cups sit secure on the wind cups shaf
ページ15に含まれる内容の要旨
Main Unit The main unit measures pressure, indoor temperature, humidity, and receives atomic time data from the US Atomic Clock and all remote weather sensors. It should be placed indoors. FEATURES Time • Precise time and date set via RF signals from US Atomic clock • 12 or 24 hour time format • Manual adjustment of time and date • Calendar displaying date with month and day in 6 languages English, German, French, Italian, Spanish and Dutch • Sunrise/set calculation for over 100
ページ16に含まれる内容の要旨
• 4 AA batteries Battery installation • Open the battery compartment door on the back of the main unit. • Insert four (4) AA size batteries according to the polarities shown and replace the battery compartment door. • Connect 7.5 V AC/DC adapter provided to the main display unit and plug into to the wall power outlet. Note: The AC/DC adaptor connection is required for automatic backlight control and a handheld remote control functions. If the main unit operates solely on the batter
ページ17に含まれる内容の要旨
any other time. In order to set the altitude, you will have to restart the main unit completely. To set the pressure & altitude units and program your altitude, use the handheld remote control or main unit control panel: Buttons and Controls Most of the handheld remote control buttons are corresponding to the main unit controls. To expose the main unit control buttons, press the OPEN button on the upper right corner of the main unit and the controls’ cover door will open.
ページ18に含まれる内容の要旨
Allows displaying the sea-level pressure history E. HISTORY Allows displaying the time alarms and alerts for the temperature, rainfall and wind. F ALARM/CHART If depressed and hold, allows entering into the alarm/alert programming mode When depressed and hold in pressure and forecast mode, allows viewing of the different bar charts Changes the temperature and humidity channel G. CHANNEL Enables the temperature and humidity channel auto-scan mode Enables a backlight for 5 sec
ページ19に含まれる内容の要旨
Pressure and Recalls the Pressure and Weather Forecast Mode Weather Forecast Mode Recalls the Rain Mode Rain Mode Sunrise/Sunset Recalls the Sunrise/Sunset Mode Mode Recalls the Clock and Alarm Mode Clock and Alarm Mode Changes bar-chart display to history for Sea-level Change Bar-chart pressure, channel 1 temperature or channel 1 relative humidity Display Navigating through the modes The main unit has seven (7) different modes (windows) each displaying the s
ページ20に含まれる内容の要旨
UV Window Displays: • UV index or Minimum Ultraviolet Exposure • Daily Maximum • Weekly Maximum • Remote UV sensor battery status Clock and Alarms Window Displays: • US Atomic Time clock with time and calendar • Single alarm, weekday alarm and ice warning alarm (pre-alarm) Sunrise/Sunset Window 20