ページ1に含まれる内容の要旨
ULTRA-1
ULTRA-2
PROGRAMMING MANUAL
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
41047.0000A 04/08 ©2008 Bunn-O-Matic Corporation
ページ2に含まれる内容の要旨
BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) All equipment other than as specified below: 2 years parts and 1 year labor. 2) Electronic circuit and/or control boards: parts and labor for 3 years. 3) Compressors on refrigeration equipment: 5 years parts and 1 year labor. 4) Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis: parts and labor for 3 years or 30,000 po
ページ3に含まれる内容の要旨
INTRODUCTION This equipment dispenses granita-type and cold liquid drinks on demand from separate hoppers. Operating controls are accessible only through password protection. CONTENTS Introduction & Warranty....................................................................................................... 3 Operating Controls ............................................................................................................... 8 Programming .........................................
ページ4に含まれる内容の要旨
OPERATING CONTROLS ULTRA-1 There are three of these switches that will be used for the operation of the dispenser. 1 2 3 P3932 1. switch (upper left corner of the control pad) This switch is the ON/OFF toggle switch which powers up the dispenser and the LCD display. When ON the Date and Time toggle back and forth continously except during programming. 2. (upper right corner) This is used to turn the auger motor to AUGER ON, AUGER OFF or AUGER REFILL ON. (Refill only ap- plicable when
ページ5に含まれる内容の要旨
OPERATING CONTROLS ULTRA-2 There are five of these switches that will be used for the operation of the dispenser. 1 P3677 2 3 4 5 1. switch (upper left corner of the control pad) This switch is the ON/OFF toggle switch which powers up the dispenser and the LCD display. When ON the Date and Time toggle back and forth continously except during programming. 2. (bottom left corner) This is used to turn the left side auge
ページ6に含まれる内容の要旨
PROGRAMMING Using the menu-driven display on the front of the dispenser, the operator has the ability to alter or modify various parameters such as beverage consistency and set day/night “ON/OFF” times. The operator is also prompted to check a variety of periodic service functions or even a step-by-step cleaning routine. There is also the opportunity to return all changes back to factory default settings. Access to most controls can be password protected to allow only qualified personnel to
ページ7に含まれる内容の要旨
PROGRAMMING THE DISPENSER During normal operations, the Date, the Time, and the Serial Number toggle back and forth continuously. The following function screens are in the order they appear from the menu display. Each screen will have instructions and procedures to program the various functions of the dispenser. HOME SCREEN Displays the TIME, DATE, SERIAL NUMBER and ASSET NUMBER which toggle back and forth continuously. JAN. 25, 2005 10:45:30 AM off off off off ULTR027930 AN000001 of
ページ8に含まれる内容の要旨
MENU FUNCTION INDEX (Continued) SET THICKNESS ? TEST AUGERS ? CLEANING GUIDE ? NO YES NO YES NO YES PASSWORD 0 SET LANGUAGE ? SET DATE TIME ? NO YES (-) NEXT (+) NO YES DEFROST MINUTES PM COMPLETE ? SET NIGHT TIME (-) OFF (+) NO YES (-) OFF (+) DAY TO CLEAN OFF YES THICK ADJUST 6 MONTH PM (-) NEXT (+) (-) NEXT
ページ9に含まれる内容の要旨
Cleaning Guide This function leads the operator through a nine step cleaning process when answered YES (“ICE”). Depress GOURMET to display the next cleaning instruction. When entering this mode, the refrigeration system will automatically turn OFF. After step when hoppers are drained, the augers will turn OFF. Three messages will display after advancing past the last cleaning instruc- tion: FINISH/NEXT, PLEASE WAIT, ULTRA VERSION #__.__. CLEANING GUIDE ? NO Y E S P3678 REMOVE HOPPERS DRAIN
ページ10に含まれる内容の要旨
Set Consistency This function allows the operator to adjust the ice consistency, or torque of each auger when answered YES (“ICE”). Two screens will appear for left and right. The operator can scroll through a range of a minimum of 1 (ULTRA) to a maximum of 16 (ICE). Factory default is 10. NOTE: ULTRA-1 models will only have one adjustment screen. SET THICKNESS ? NO YES P3678 MIN RIGHT 5 MAX MIN LEFT 9 MAX 41047 040108 10
ページ11に含まれる内容の要旨
Test Augers This function tests the operation of forward and reverse of each auger motor. Left auger appears first. Press the ICE hidden switch to toggle between OFF, FORWARD and REVERSE. Press GOURMET hidden switch to repeat the operation for the right auger motor. A one minute time out will return to the Home Screen. LEFT AUGER TEST TEST AUGERS ? NEXT FORWARD NO YES LEFT AUGER TEST LEFT AUGER TEST NEXT OFF NEXT REVERSE Select NEXT to repeat process for Right Auger Test. NOTE: ULTRA-1 mo
ページ12に含まれる内容の要旨
Password From this screen, the operator must know the password before moving on to the remaining functions. The range is from 0 - 9999 with the factory default being 0. PASSWORD 0 (-) NEXT (+) P3678 Set Language ? (Late Model Dispensers) The setting of the Set Language mode allows the operator to scroll thru a list of languages stored in the software and select one for the display messages. SET LANGUAGE ? NO YES ENGLISH ESPANOL (-) SELECT (+) (-) SELECCION
ページ13に含まれる内容の要旨
Set Night Time/Set Day Time The setting of the Day/Night mode allows the dispenser to “power down” during off hours. The bottom corners displaying “ICE” will change to “CHILL” during the night mode. During the night mode, the product will be kept chilled to below 35°F. “ICE” reading will return after night mode elapses. With “OFF” representing 12:00 AM, the operator can scroll to the times desired for the night time mode to begin and end. SET NIGHT TIME SET DAY TIME (-) OFF (+) (-) OFF (
ページ14に含まれる内容の要旨
Preventive Maintenance Complete? This function is used to reset a reminder message Preventive Maintenance Due every six months. The machine will not shut down if service is not performed. When the service is performed and the message is answered YES (ICE), the time and date is recorded for another six months to elapse. This feature can be DISABLED by pressing (-) ULTRA hidden switch. PM COMPLETE ? NO YES 6 MONTH PM (-) ON (+) 41047 040108 14
ページ15に含まれる内容の要旨
Day To Clean Off This function allows the operator to program a cleaning schedule from 1 to 14 days. The default screen is 0 or OFF. Selecting - or ULTRA will prompt the screen Days To Clean. Once a number of days is selected the screen will prompt two functions, CLEAN MESSAGE ONLY or CLEAN LOCKOUT. On the day selected, the display will toggle between DATE & TIME and CLEAN DUE TODAY. The dispenser will lock into night mode at midnight if “Clean Lockout” is activated. To reset the Clean Due
ページ16に含まれる内容の要旨
Consistency Adjust Lock This is an option of locking the Set Consistency function by selecting + (YES) or - (NO). NO THICK ADJUST YES THICK ADJUST (-) NEXT (+) (-) NEXT (+) 41047 040108 16
ページ17に含まれる内容の要旨
Switches Enabled This function allows the operator to lockout the touch pad. Selecting + (ON) provides no time delay on switches except for the center (GOURMET) hidden switch. Selecting - (LOCKOUT) provides a five second hold to wake up the touch pad and a two minute time frame from last button pressed to make adjustments before returning to sleep mode (five second hold). SWITCHES SWITCHES (-) ON (+) (-) LOCKOUT (+) 41047 040108 17
ページ18に含まれる内容の要旨
Refill Threshold (Late Model Dispensers with Refill Kit Installed only) This function allows the operator to adjust the Refill Threshold depending on the type of product being dis- pensed. 250 L REFILL 155 250 R REFILL 155 (-) THRESHOLD (+) (-) THRESHOLD (+) TEST REFILL ? NO YES ACTIVATE VALVE LEFT DONE RIGHT ULTRA-1 Models only: This function will activate the Liquid Autofill function only in machines equipped with this option. ENABLE REFILL ? (-) OFF (+) 4
ページ19に含まれる内容の要旨
Ad Messages Enabled (Late Model Dispensers) This function allows the operator to create an AD Message that will toggle with the Home Screen mes- sages. AD MESSAGE AD MESSAGE (-) DISABLED (+) (-) ENABLED (+) MODIFY MESSAGE ? NO YES SCROL THRU ALPHA (MESSAGE) NEXT-NEXT LETTER SCROL DONE NEXT SAVE ? AD MESSAGE NO EDIT YES SETUP COMPLETE 41047 040108 19
ページ20に含まれる内容の要旨
Enter Asset Number This is the function to set the asset number using a range of 0 to 999999 (the factory default is 0). It is used to track the usage or service of an individual machine within a group. ENTER ASSET # AN000000 Set Password This is the function to set the password using a range of 0 to 9999 (the factory default is 0). When the pass- word is set, the operator can only access the first four functions: Cleaning Guide, Set Consistency, Test Augers and Set Date & Time. SET PASS WR