ページ1に含まれる内容の要旨
INSTALLATION AND OPERATION INSTRUCTIONS
FLAT TOP BOTTLE COOLER
MODEL NOS.
BC24 Series
BC36 Series
BC48 Series
BC60 Series
BC72 Series
BC96 Series
IMPORTANT INFORMATION
Table of Contents
Cabinet Specifications ..........................................2
This manual has been prepared to assist you in the
Installing
installation of your Bottle Cooler and to acquaint you
Uncrating and Inspection ................................3
with its operation and maintenance.
Plumbing ..........................
ページ2に含まれる内容の要旨
Installation and Operating Instructions Sizes and Specifications, Flat Top Bottle Coolers MODEL NUMBERS BLACK BC24PG BC36PG BC48PG BC60PG BC72PG BC96PG STAINLESS EXTERIOR BC24SG BC36SG BC48SG BC60SG BC72SG BC96SG STAINLESS INTERIOR BC24SS BC36SS BC48SS BC60SS BC72SS BC96SS ALL STAINLESS BC24AS BC36AS BC48AS BC60AS BC72AS BC96AS SPECIFICATIONS LENGTH (mm) 24” (610) 36” (915) 48” (1219) 60” (1524) 72” (1828) 96” (2438) 3 INTERIOR CU. FT. (m ) 3.75 (0.10) 7.83 (0.22) 11.68 (0.33) 15.53 (0.44) 19.38
ページ3に含まれる内容の要旨
Preparing the Cabinet – Flat Top Bottle Coolers Uncrating and Inspection Placing the Cabinet Remove all crating material before operating. To assure maximum performance, fresh air must Carefully inspect cabinet for hidden damage. be allowed to circulate through the machinery If damage is discovered, file your claim immediately compartment. It is important to allow at least two with the transport company. Perlick is not inches of clearance at the back or left end of the responsible for damage in
ページ4に含まれる内容の要旨
How To Operate – Flat Top Bottle Coolers Temperature Control Cleaning the Doors: An adjustable temperature control is located inside Doors should be periodically removed from the the Bottle Cooler on the evaporator fan panel cabinet and inspected for a buildup of foreign assembly. It is factory set at “Normal” approximately materials, such as syrups, beer, etc. Buildups 38° F. Make adjustments as shown to attain the on the underside of the doors, along with the desired temperature. cabinet
ページ5に含まれる内容の要旨
Wiring Diagram – Flat Top Bottle Coolers EVAP. WHITE FAN TEMPERATURE CONTROL EVAP. FAN 2ND FAN ON 4’ THRU 8’ MODELS WHITE BLACK BLACK GREEN RED PLUG-IN-CORD TO CONDENSING UNIT INSIDE OF INSIDE OF CONDENSING CABINET UNIT HOUSING Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice. Form No. Z2219 5 Rev. 4.15.06
ページ6に含まれる内容の要旨
Replacement Parts – Flat Top Bottle Coolers 7 23 9 5A 14 19 8 17 5 4 6 21 18 22 20 12 13 1 10 11 2 3 15 CAUTION Service should be done by a qualified refrigeration technician. Disconnect all power before servicing the cabinet. Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice. Form No. Z2219 6 Rev. 4.15.06
ページ7に含まれる内容の要旨
Replacement Parts – Flat Top Bottle Coolers MODEL NOS. BC24 BC36 BC48 BC60 BC72 BC96 Item Description Part Numbers Complete condensing unit C22648 C22648 C22647 C22646 C22646 C22646 1 Replacement compressor R134a 513307046 513307046 513200314 513200003 513200003 513200003 2 Condensing unit fan motor assy. 215315009 215315009 215315009 215315009 215315009 215315009 Terminal board 219101538 219101538 219101538 219101538 219101538 219101538 Overload protector 4TM762NFBZZ-53 MRT20AGK5590 MRT22AFZ559
ページ8に含まれる内容の要旨
8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414-353-7060 • Fax 414-353-7069 Toll Free 800-558-5592 • E-Mail: Perlick@Perlick.com • www.Perlick.com Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice. Form No. Z2219 Rev. 4.15.06