AF PR-2
BUNN
AF PR-3
AFPR-3 VERSION DISCONTINUED
The information in this manual
is no longer current.
OPERATING & SERVICE MANUAL
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
28791.0001B 1/00 ©1998 Bunn-O-Matic Corporation
ページ2に含まれる内容の要旨
INTRODUCTION This equipment supplies a premixed liquid product to the hoppers on the CDS-2 or 3 dispensers. It is for indoor use only on a sturdy counter or shelf. WARRANTY Bunn-O-Matic Corp. (“Bunn”) warrants the equipment manufactured by it to be commercially free from de- fects in material and workmanship existing at the time of manufacture and appearing within one year from the date of installation. In addition: 1.) Bunn warrants electronic circuit and/or control boards to be commerciall
ページ3に含まれる内容の要旨
INITIAL SET-UP NOTE: This refill unit should not be used to initially fill the hopper. Running the motor for extended periods will trip the thermal switch. The thermal switch will reset, but requires up to 30 minutes of cooling time. NOTE: Hoses, clamps and product container connectors are not supplied. Fittings and labels are supplied. Make hose assemblies as required. 1. Assemble hoppers with probe housing assemblies to CDS-2, CDS-3 or modify existing hoppers using tem- plate provided. 2. M
ページ4に含まれる内容の要旨
CLEANING RECOMMENDED WEEkLY CLEANING: This should be done in conjunction with the recommended weekly cleaning of your CDS-2 or CDS-3 machine. The CDS Hoppers must be empty before starting. 1. Prepare a 1 gallon cleaning solution consisting of 1 gallon of hot water and a sanitizing cleaner which contains 3-5% chlorine based sanitizer. Mix per manufacturers instructions 2. Remove connectors from each concentrate container and place them directly into the cleaning solution. 3. Energize each refil
ページ5に含まれる内容の要旨
OPERATING CONTROLS B A P2052 A. MAIN POWER ON/OFF The main power ON/OFF switch is located on the right of the front panel just above the power cord. B. REFILL CIRCUIT ON/OFF The refill circuit ON/OFF switches are located on the right of the front panel just above the main power switch. These allow each circuit to operate independently of the other. C. PROBE CONTROL BOX LOW/OFF/HIGH On models equipped with a dual level probe, there is a LOW/OFF/HIGH switch located at the probe control box on t
ページ6に含まれる内容の要旨
TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY 1. Empty product container Replace or refill Product will not dispense 2. No power or incorrect voltage to (A1) Check the outlet for 120 volts the dispenser on two wire 120 volt dispenser. (A2) Check the outlet for 200 volts or 240 volts ac for two wire 200 volt or 240 volt dispensers. (B) Check circuit breakers or fuses. 3. Signal cable unplugged Signal cable must be plugged in. 4. Hopper is full Product must not be touching probes to fi
ページ7に含まれる内容の要旨
SERVICE This section provides procedures for testing and replacing various major components used in this dispenser should service become necessary. Refer to Troubleshooting for assistance in determining the cause of any problem. WARNING - Inspection, testing, and repair of electri- cal equipment should be performed only by qualified service personnel. The dispenser should be unplugged when servicing, except when electrical tests are re- quired and the test procedure specifically states
ページ8に含まれる内容の要旨
SERVICE CIRCUIT BOARD Removal and Replacement: 1. Disconnect the ten pin plug from the main wiring harness to the circuit board. 2. Remove the six #4-40 screws and spacers securing the circuit board to the solenoid mounting bracket. Remove circuit board and discard. 3. Install new circuit board using #4-40 screws and spacers to secure the circuit board to the vacuum switch mounting bracket. The spacers must be between the solenoid mounting bracket and the circuit board. 4. Refer to Fig.
ページ9に含まれる内容の要旨
SERVICE FUSE AND FUSE HOLDER Removal and Replacement: Fuse: 1. Remove the cap from the fuse holder. 2. Remove fuse from the fuse holder, inspect, if blown discard. 3. Install new 10 amp fuse in the fuse holder. 4. Reinstall fuse holder cap. Fuse Holder: 1. Disconnect the wires from the rear of the fuse holder. 2. Remove the nut securing the fuse holder to the P1561 front of the main mounting panel. FIG. 4 FUSE HOLDER 3. Push the fuse holder through the hole in the panel. Location: 4. Inst
ページ10に含まれる内容の要旨
SERVICE (cont.) MAIN ON/OFF SWITCH If voltage is present as described, proceed to #5. If voltage is not present as described, refer to the wir- ing diagrams and check the dispenser wiring harness. 5. Check for continuity across the switch terminals with the switch in the “ON” position. Continuity must not be present when the switch is in the “OFF” position. If continuity is present as described, reconnect the wires to the switch terminals. If continuity is not present as described, replace t
ページ11に含まれる内容の要旨
SERVICE (cont.) PROBE SYSTEM Probe Boxes: 1. Disconnect the signal cable from the probe boxes. 2. Remove probe box from CDS hopper. 3. Place the switch on the probe box in the “HIGH” position. 4. Check the resistance across the box cable pins, see Fig. 8B. AFPR-2 & 3 P1539 FIG. 8B PROBE BOX CABLE PINS 5. With the probe box switch in the “LOW” position check the ohms across the pins, refer to Fig. 8B. P1523 6. If readings match the values indicated the probe FIG. 8 PROBE SWITCHES system e
ページ12に含まれる内容の要旨
SERVICE (cont.) wires to the switch terminals. REFILL SWITCHES If continuity is not present as described, replace the switch. Removal and Replacement: 1. Remove the wires from the switch terminals. 2. Compress the clips inside the autofill box and gently push the switch through the opening in the front of autofill box. 3. Push the new switch into the opening and spread the clips to hold switch in the autofill box. 4. Refer to Fig 13 when reconnecting the wires. #1 AFPR-2 & 3 P1561 FIG. 12 R
ページ13に含まれる内容の要旨
SERVICE (cont.) a) 120 volts ac for two wire 120 volt models. VACUUM/SUPPLY PUMP ASSEMBLY b) 200 to 240 volts ac for two wire 200 or 240 volt models. If voltage is present as described, replace the pump. If voltage is not present as described, refer to the wiring diagrams and check the main wiring harness. Pump Removal and Replacement: 1. Disconnect the wires from the pump leads. 2. Disconnect the input and output tubes. 3. Remove the four thumb screws securing the pump head to the pump bod
ページ14に含まれる内容の要旨
SERVICE (cont.) VACUUM/SUPPLY PUMP TUBE INSTALLATION 1. Separate the pump head from the pump body. Hold pump head as shown in Fig. 18, with roller in the 2, 6 10 o’clock positions. ROLLERS 2. Wrap tubing around rollers and hold as shown in PUMP Fig. 18. HEAD 3. Insert the slot of the tubing key (supplied), as shown in Fig. 18 on the rotor so the bottom edge of the key is pressing the tubing into the pump head cavity. 4. Push down and turn the key counterclockwise to TUBING guide the tub
ページ15に含まれる内容の要旨
SERVICE (cont.) VACUUM SWITCHES Removal and Replacement: 1. Disconnect dispenser from the power source. 2. Remove the four thumb screws securing the right side pump head to the right side pump. 3. Disconnect the input tube from the pump to vacuum switch to be removed. 4. Remove the two #8-32 keps nuts securing the pump and bracket to main panel. 5. Disconnect the yellow and white wires from the pump. 6. Remove pump and bracket as an assembly. 7. Disconnect the input tubes from the vacuum sw
ページ16に含まれる内容の要旨
28791.1 011500 16
ページ17に含まれる内容の要旨
28791.1 011500 17