ページ1に含まれる内容の要旨
SERVICE
5
B1100028
English 1 (5)
SB, Automower, New Software for 305, 305, 2011-04
General information
New Main software, MMI (Man Machine Interface) software and Sub System software have been
® ®
released for Automower 305. It is recommended to update all Automower 305 before delivery to
end customer.
• New Main Software (MSW): 1.01.00
• New MMI Software (MMI): 1.04.00
• New Sub System Software (SUB): 1.01.00
The new softwares includes the following changes:
• Calibration of guide has been
ページ2に含まれる内容の要旨
SERVICE 5 B1100028 English 2 (5) Calibration of guide is done automatically first time the mower leaves the charging station in the following situations: • New mower first start up • Always at Test Out • After changing guide width to Medium or Wide • After performing Factory reset • After changing main circuit board • After main software update Sub System Software In mower menu Tools -> Info -> General, the line “Sub-ver” has been added. That software con- trols the cutting motor. The Sub syste
ページ3に含まれる内容の要旨
SERVICE 5 B1100028 English 3 (5) New message codes in display For improved diagnostic some extra message-codes have been added to the message “Electronic problem”. The message code appears within parenthesis after the message in mower display. The message code is not stored in the message history list nor in Autocheck logfile. Code Message Cause Action 501 Electronic problem Communication Main switch Off/On problem between MMI cir- Check that wire between MMI circuit board and cuit board a
ページ4に含まれる内容の要旨
SERVICE 5 B1100028 English 4 (5) Installation Use Autocheck EXP (part number 577 85 81-01) to make an automatic programming of the new ® main software and MMI software. Former Autocheck 9.X can not be used with Automower 305. Please follow below guide for how to make an automatic programming in Autocheck EXP. 1. Start and login to Autocheck EXP. 2. Check that there are no uninstalled updates of Autocheck EXP. If there is any update avail- able, install it before continue to step 3.
ページ5に含まれる内容の要旨
SERVICE 5 B1100028 English 5 (5) 6. Choose Programming -> Program in the top menu. 7. Under the heading Automatic programming, click Start. 8. Update of Main software and MMI software has been completed when the text Programming finished appears under the heading Status.