ページ1に含まれる内容の要旨
1 y Read2 ready
3 d reay
1 Ready 2 Ready 3Ready
4 Ready 5 testing 6 Chrg
R
ANALYZER X3 & X6
User’s Manual
W & W Manufacturing Co.
800 South Broadway
Hicksville, NY 11801
In USA & Canada: 800-221-0732
In N.Y. State: 516-942-0011
Fax: 516-942-1944
E-Mail: email@ww-manufacturing.com
Website: http://www.ww-manufacturing.com
3 MINUTE
BATTERY
All specifications are subject to change without notice.
ANALYZER
!
MADE IN
USA BY:
W & W Manufacturing Co.
Copyright Version 210.19.07.
ページ2に含まれる内容の要旨
Notes Table of Contents Safety and Precautions……………………………………………3 Features……………………………………………………………..4 Specifications……………………………………………...............5 Part Overview…………………………………………………….…6 Understanding the X3’s adapters Cup………………….……….7 Getting started …………………………………………....………8 Quick Test Analysis………………………………………..……......9 Cycle Mode…………………………………….…......................10 Auto Mode.................………………………………….…………11 Condition Mode……………………………………….....….. .....12 Disc
ページ3に含まれる内容の要旨
Notes Safety and Operating Environment Always use a grounded AC outlet to power the Analyzer X3 & X6. Keep the Analyzer X3 & X6 at least one-foot away from any object to allow for proper ventilation. Do not Analyze Batteries outside the recommended temperature ranges. For good and consistent results, 25°C (Room temperature) is recommended. Allow batteries to stabilize to room temperature before analyzing. Do not exceed the battery manufacturer’s recommended voltage, charge current and
ページ4に含まれる内容の要旨
Universal cup OVERVIEW The Universal cup will allow one to evaluate batteries with different chemistries and cell counts within defined The W&W Analyzer X3& X6 is a programmable battery tester and battery cycler capable of testing a variety specifications. The Universal cup has one memory location that can be programed the same as the Learn of battery chemistries such as; Lithium Ion, Lithium Polymer, Nickel Cadmium and Nickel Metal Hydride. Memory location in a standard cup. Most me
ページ5に含まれる内容の要旨
Learn Mode X X3 & X6 Specifications This mode when selected will allow a battery’s parameters to be created for new battery models. A battery “Adapter Cup” holds a total of 5 battery profiles for parameter storage; four are preprogrammed Station Std Power Supply Hi Power Supply with OEM information for a particular battery series. The fifth profile can be modified by the “Learn Mode”. During entry into the “Learn Mode”, Battery Chemistry, Capacity, and the number of Cells are
ページ6に含まれる内容の要旨
Parts Overview Impedance Test Impedance of a battery can be a good indicator of degradation of a battery’s performance. In general, the lower the impedance number the better the battery performance during discharge. As a battery ages the impedance starts to rise indicating possible problems with the electrolyte, separator, contact corrosion, or metal interfaces, all impact the impedance. The initial impedance of a new batter y should be recorded and compared through the life of a batte
ページ7に含まれる内容の要旨
Charge Mode Understanding the Analyzer X3’s and X6’s Adapter CUP The Analyzer X3 and X6 applies two types of charge algorithms for the two types of chemistries. For Nickel based battery chemistries, a constant current of 1C (changeable with software option) is applied The “Adapter Cup” allow different batteries to be serviced by the Analyzer X3 and X6. until the battery voltage peaks and descends negative. A top off current or 0.2C is then applied for 30 Each “Adapter Cup” is made for a s
ページ8に含まれる内容の要旨
Discharge Mode Getting Started The Analyzer X3 and X6 is capable of a single discharge cycle by selecting Discharge Mode. In the normal discharge mode a constant pre-stored load current (C/5) is applied to the battery until 1volt Power Up per cell has been reached. The result of the measurement is displayed as a percent of capacity. The - Connect the unit to the proper AC voltage and capacity of a battery is defined as the amount of current over time. So the discharge result sh
ページ9に含まれる内容の要旨
QUICK TEST ANALYSIS Condition Mode The CONDITION CYCLE serves basically two needs of Nickel based batteries, one is to reform the This is an advanced proprietary algorithm capable of determining the health of a battery. Specially stored Cells of a battery that hasn’t been used for an extended period of time, say for 3 or more Months. Secondly this mode will eliminate MEMORY EFFECT better known as VOLTAGE DEPRESSION. parameters allowing the Analyzer X3 or X6 to identify a battery’s
ページ10に含まれる内容の要旨
Cycle Mode Auto Mode The Cycle mode will cycle a battery through a charge and discharge cycle, known as Cycle (1). One could Life cycle testing can be accomplished by choosing the Auto test. Battery performance for multiple cycles can be Select, Cycle 1, 2 or 3. By selecting cycle 1,2 or 3 all one would be doing is repeating the Charge/discharge evaluated as long as the battery is not removed. Charge and discharge cycles are performed with 10-minute rest in between charge and discha