ページ1に含まれる内容の要旨
QUICK LINKS
Contents
Index
Regulatory Compliance
Product Information
Warranty
Planar Battery System
GETTING STARTED
Model BAT24SI
About the Battery System
Battery Components
Identify Connector Ports
OPERATIONS MANUAL
Install Fuses
USING THE BATTERY
Charge Battery
Set Up Power Management
MAINTAINING THE BATTERY
Replace Battery
Troubleshooting
APPENDIXES
Battery Disposal
Specifications
www.planar.com
ページ2に含まれる内容の要旨
Planar Systems, Inc. © 2004. All rights reserved. QUICK LINKS Information in this document has been carefully checked for accuracy; however, no guarantee is Contents America Sales given to the correctness of the contents. This document is subject to change without notice. Planar Planar Systems, Inc. Index provides this information as reference only. Reference to other vendors’ product does not imply 1195 NW Compton Drive any recommendation or endorsement. Beaverton, OR
ページ3に含まれる内容の要旨
QUICK LINKS Contents Contents Index Product Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv Regulatory Compliance Product Information About the Planar Battery System. . . . . . . . . . . . . . . . . . . . . . . . . 1 Warranty Battery Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 GETTING STARTED Identify the Connector Ports. . . . . . . . . . . . . . . . . . . . . . . .
ページ4に含まれる内容の要旨
QUICK LINKS Product Information Contents Warning Index Safety guidelines • Equipment is not suitable for use The Planar battery system is designed to ensure both the highest level of product quality Regulatory Compliance in the presence of a flammable and safety for the user. To maintain both quality and safety, follow the guidelines and anesthetic mixture with air, Product Information instructions in this manual. oxygen, or nitrous oxide. • Use the ba
ページ5に含まれる内容の要旨
QUICK LINKS Cleaning guidelines Contents The Planar battery system continues to operate normally while being cleaned in a fashion normal for a hospital environment. Use a damp, mildly soapy cloth to clean Index the exterior chassis. Drip protection is provided in accordance with the IPX1 rating, defined in the IEC/EN60529 standard. Regulatory Compliance Product Information Service support Warranty Other than battery installation and replacement, the Planar battery system req
ページ6に含まれる内容の要旨
QUICK LINKS About the Planar Battery System Contents Certification The Planar Battery System, model BAT24SI, is designed specifically for point-of care Index use. It is modular, compact, and ergonomically suited for effective utilization in the The Planar Battery System is a medical environment. recognized UL 60601-1 component. Regulatory Compliance Planar does not certify it for use with The battery system supplies a regulated +12 VDC. It contains two sealed lead acid
ページ7に含まれる内容の要旨
QUICK LINKS Battery Components Contents The Planar Battery System ships with all the components you need to make Index it operational. Regulatory Compliance Product Information Warranty Battery unit, model BAT24SI GETTING STARTED About the Battery System Battery Components Identify Connector Ports Install Fuses Input power cord USING THE BATTERY Charge Battery Set Up Power Management USB cable MAINTAINING THE BATTERY Replace Battery Output power cord Troubleshooting APPENDIXE
ページ8に含まれる内容の要旨
QUICK LINKS Identify the Connector Ports Contents All external connections to the battery unit are located on the rear of the enclosure. Legend Index The design of the enclosure minimizes liquid ingress. 1 Standard IEC 120–250 VAC input power Regulatory Compliance 2 A, 250 V replaceable Product Information 2 USB serial port Communication channel Warranty between the power supply and its host computer GETTING STARTED 3 12V DC 6 A output power About the Battery System Mini-
ページ9に含まれる内容の要旨
QUICK LINKS Install the Fuses Contents About the battery fuses You need the three fuses and a #2 flathead screwdriver for this installation. Index The Planar Battery System requires To install the fuses two 6 A fuses (size 0.25 in. x1.25 in.; Regulatory Compliance F type). These are available from 1 Insert the two fuses for the battery into the ports on the rear of the enclosure. any hardware store. Push the fuses in until you feel the connection. Repeat to install t
ページ10に含まれる内容の要旨
QUICK LINKS Charge the Battery Contents Sealed lead-acid batteries are cost-effective and can provide a sizable amount of Index energy per battery weight. However, the energy storage potential of the batteries does decay over time. Regulatory Compliance Refer to these web sites for more information on sealed lead-acid batteries: Product Information http://www.houseofbatteries.com/HowTo/SLA.htm http://www.devicelink.com/mem/archive/03/10/003.html Warranty Battery chargin
ページ11に含まれる内容の要旨
Periodically, charge the battery for 10 hours. This assures that the maximum charge QUICK LINKS capacity of the battery is maintained. The charger enters the trickle charging cycle Contents after the current supplied to the batteries drops below .5 amps. Charge the batteries Index for 10 hours for every eight charges to 100%. Regulatory Compliance Battery discharging Product Information You discharge the battery by (1) disconnecting the battery system from the AC power
ページ12に含まれる内容の要旨
QUICK LINKS Set Up the Power Management System Contents All communications occur through the USB serial interface. These are displayed Easier power management Index through the Windows Power Options Properties dialog on the host computer. The charge level indicator is software-driven, complying with Regulatory Compliance To set up power management the Microsoft Windows HID Power Device Specification. 1 Open the Control Panel and click the Power Options tool. Product In
ページ13に含まれる内容の要旨
2 Click the Alarms tab on the Power Options Properties dialog. QUICK LINKS Contents Recommended alarm settings Index • Low battery alarm – activate at 3% The alarm is triggered when the Regulatory Compliance battery charge level reaches its low Product Information battery limit. • Critical battery alarm – activate at 0% Warranty The alarm is triggered when the battery charge level reaches its GETTING STARTED depth of discharge limit. About the Battery System Hiber
ページ14に含まれる内容の要旨
4 Select the notification you want, one of the two types or both. Click OK. QUICK LINKS Contents Recommended alarm notification Index • Low battery alarm Notification: Sound, Text Regulatory Compliance Action: No action Product Information Run Program: None Warranty • Critical battery alarm Notification: None GETTING STARTED Action: Hibernate About the Battery System Run Program: None Battery Components Identify Connector Ports To set an alarm action: 1 Click the check box
ページ15に含まれる内容の要旨
5 Open the Power Meter tab to check the power status of each battery. QUICK LINKS • Click the check box to see the details on a battery. Contents • Click a battery icon for more information. Index Regulatory Compliance Product Information Warranty GETTING STARTED About the Battery System Battery Components Identify Connector Ports Install Fuses USING THE BATTERY Charge Battery Set Up Power Management MAINTAINING THE BATTERY Replace Battery Troubleshooting APPENDIXES Battery Disposal Specifica
ページ16に含まれる内容の要旨
QUICK LINKS Replace the Battery Contents You need a #2 Phillips screwdriver and a #2 flathead screwdriver for this installation. Index To remove the battery tray Regulatory Compliance Product Information Warranty GETTING STARTED About the Battery System Battery Components Identify Connector Ports 1 Use the Phillips screwdriver to remove 2 Unplug the USB cable and the 3 Unplug the power cord. Install Fuses the two screws from the front of the output power cable. enclosure. Then remove the s
ページ17に含まれる内容の要旨
To remove the used batteries QUICK LINKS Contents Replacement tips Never insert fuses into or remove Index them from the battery with the load Regulatory Compliance plugged in. Doing so can cause permanent damage to the system. Product Information The battery system weighs about Warranty 25 pounds and is heavily weighted toward the front. Handle it carefully. GETTING STARTED Once the unit is completely out of the enclosure, move it to a flat and About the Battery System 1 Remove the tw
ページ18に含まれる内容の要旨
To reinstall the battery system QUICK LINKS Contents 1 Install new batteries into the tray. Replace both batteries at the same time. Do not mix old and new batteries Index 2 Reconnect the battery cables to the controller board and to the four battery Regulatory Compliance terminals. Be sure that cable and terminal connections match RED-to-RED and BLACK-to-BLACK. Push in each connector until you feel the connection click. Product Information 3 Reattach the retaining bracket with the two Phill
ページ19に含まれる内容の要旨
QUICK LINKS Troubleshooting Contents Index Problem Possible Cause Possible Solution Regulatory Compliance The battery system not functioning, AC power is not connected. Make sure power cord is connected properly. no output power, does not charge Product Information Input fuse needs to be replaced. Replace fuse in the input AC connector. when connected to AC power. Replace with UL-recognized fuse 2 A, Warranty 250 VAC, fast acting, size 5 mm x 20 mm. GETTING STARTED Over-temperature protection
ページ20に含まれる内容の要旨
QUICK LINKS Battery Disposal Contents Industrial batteries contain lead and sulfuric acid, which are both considered Index “hazardous substances.” If batteries are improperly disposed of, for example, thrown in the trash or illegally dumped, these substances can eventually leak out and Regulatory Compliance contaminate the surrounding soil and groundwater supply. Product Information It is a federal law to properly dispose of lead-acid batteries once they can no longer be Warranty used. Once