ページ1に含まれる内容の要旨
Supported Capacity*: 100 to 20,000mAh
Charger Input Power: 12V 2.0A
Adapter Input: 100-240V 50/60Hz
* Always ensure that the batteries can accept the programmed rates.
MH-C9000
WizardOne Charger-Analyzer
Thank you for purchasing the Powerex MH-C9000
Charger-Analyzer. Read these instructions carefully
and thoroughly before operating this unit. IMPORTANT
SAFETY INSTRUCTIONS. READ AND SAVE THESE
INSTRUCTIONS.
OPERATING THIS PRODUCT INCORRECTLY CAN
CAUSE DAMAGE
ページ2に含まれる内容の要旨
Battery Rescue Steps MODES OF OPERATION For batteries that do not perform favorably after using the mode This section explains various modes and when to use them. To enable recommended above, the following sequence can be applied. each mode, refer to the “Operation” section. 1. Refresh & Analyze for one to three times. 2. If capacity is still low, use Break-In mode. Charge Mode 3. If the step 1 to step 2 shows some capacity improvement (> 10%), • Recharges the battery
ページ3に含まれる内容の要旨
If REFRESH & ANALYZE mode is selected: The charger will prompt for the charging rate by flashing “SET CHG RATE.” Use the UP and DOWN key to choose the desired current. Press ENTER to make the selection. Then it will prompt from the discharging rate by flashing “SET DISCHG RATE.” Follow the same procedure as above. 6. To ensure safety, the charger performs an “impedance check” at the beginning of the program. If the battery fails this test, “HIGH” would be disp
ページ4に含まれる内容の要旨
For CYCLE mode, the discharge capacity of the final cycle is displayed. “CYCLE HISTORY” icon will also be shown. Use the UP and DOWN key to access discharge capacity for all the cycles performed. The capacity information will be stored as long as the battery is inserted in the charger. It will be lost upon removal of the battery. Note the charging capacity is usually higher than the actual capacity of the battery owing to some energy lost as heat. Charging capacity THREE