ページ1に含まれる内容の要旨
4.4 Battery charger(BC-6158)
4.4 Battery charger (BC-6158)
4.4.1 Connection of battery charger and battery monitor circuit
Battery charger BC-6158 is controlled from the battery control panel of the console
panel.
BC-6158 05P0607
TB3
BATT CH. SW
3. (+)BATT OUT 4. BATT+
4. (-)BATT OUT 5. BATT- AUTO
OFF
3. CHRG-L
6. CHARGE
CHARGE
CHARGE
EMG
Lamp
K1
T1
A
V
EMG LIGHT
6. LAMP 2(NC)
AC iN
ON
7. LAMP 1
OFF
REC
IN USE
1. 24V 2. EMG L MF/HF SSB
RC-1800T only Illuumination
Lamp
TB2
AC FAIL
60A
1. BAT
ページ2に含まれる内容の要旨
4.4 Battery charger(BC-6158) 4.4.3 Battery charger (BC-6158) Battery charger BC-6158 can charge clad type or pasteboard vent type batteries of up to 300 AH. It is a constant voltage/current charger which supplies a constant voltage of 28 V and a constant charging current of 20 A (30 A). V 28V Fig. 4.4.4 I 20A(30A) The power supply to the charger is connected to a tap of transformer T1 which is selected according to the supply voltage. The maximum charging current differs according to t
ページ3に含まれる内容の要旨
3.4 BC-6158 3.4 BC-6158: Battery charger unit CR2 R3/4 C3 (0.01ohms) Q1 R1/2 Rectifier S1: 60 degrees T1 (U2) thermal sensor (0.5Ω /50W) Rectifier (U1) 05P0659 board Breaker: :30A C1 (CP1) K1 (Input rlay) Upper terminal:TB2 TB3 Lower terminal:TB1 Fig. 3.4.1 BC-6158 VR1 VR2 (Over voltage ADJ. VR.: (Over current ADJ. VR.: Adjust to 28V) Adjust to 20A) Q1 05P0659 R3/4 (0.01ohms) S1: 60 degrees thermal sensor Fig. 3.4.2 BC-6158 left side 3-12