ページ1に含まれる内容の要旨
834168 C P0811JZ
IS SERIES
Commercial & Security Video Intercom system
INSTALLATION MANUAL
Thank you for selecting Aiphone for your communication and security needs. Please read this manual carefully before installation,
and keep it in a safe place for future reference.
Also read the SETTING MANUAL and OPERATION MANUAL on the bundled CD-ROM.
When the installation is completed, confi gure the system by following the SETTING MANUAL. Otherwise, the system will be non-
functional.
IMPORTANT
•
Do
ページ2に含まれる内容の要旨
CONTENTS Specifi cations ..................................... 16 ■ PRECAUTIONS ................................ 3 ■ Connections ....................................... 17 WARNING .......................................3 CAUTION ........................................3 Color monitor master station (IS-MV) ..........................................18 GENERAL PRECAUTIONS ............3 Accessories ........................................ 18 ■ Notes on using this system ..........4 ■ Mounting ...
ページ3に含まれる内容の要旨
PRECAUTIONS General Prohibitions Prohibition to Dismantle the Unit Prohibition on Subjecting the Unit to Water General Precautions 10. Do not put anything on the unit or cover the unit with cloth, etc. WARNING Fire or unit trouble could result. 11. Do not install the unit in any of the following locations. Fire, Negligence could result in death or serious injury. electric shock, or unit trouble could result. 1. Do not dismantle or alter the unit. Fire or electric shock could *
ページ4に含まれる内容の要旨
This manual was created by Aiphone Co., Ltd., all rights reserved. • Notes on using this system Copying a part of or this entire manual without prior permission from Aiphone Co., Ltd. is strictly forbidden. The ID/Password to access the web server for setting the system Please note that images depicted in this manual may differ from the • • actual images. is the customer's responsibility. Make sure you set a password that cannot be easily guessed by a third party. We recommend that you Pl
ページ5に含まれる内容の要旨
System confi guration examples ■ Standard (IP) system The following is an example of standard (IP) system for controlling security and communication for facilities. A site must be confi gured with an IP-based system. • A standard (IP) system can consist of local systems and IP units. • A local system (Hard wired network system) without connecting to an IP network can also be an independent system. • When using a local system as an independent system, it needs at least one central control unit
ページ6に含まれる内容の要旨
CONNECTIONS System connection diagram The following is an example of standard (IP) system connection diagram. * Refer to page 9 to 26 for details about each unit connection. To Internet/WAN Broadband router PBX / Telephone Switch (Hub) *1 IS-IPC IP IS-PU-UL or IS-PU-S Local system IS-MV (Max. 4) Monitor IS-CCU (Max. 1) Timer Recorder CD player IS-PU-UL IS-DV/IS-DVF PT or /IS-SS AC IS-PU-S IS-RS transformer (Max. 4) EL-12S and Electric door /or strike PA speaker PA amplifi er IS-SCU (Max. 2) P
ページ7に含まれる内容の要旨
: IS system product : IP unit IP Telephone network LAN (IP network) Switch (Hub) Switch (Hub) Switch (Hub) PBX / Telephone Switch (Hub) IS-IPMV 1 IS-IPC* IS-IPDV IP /IS-IPDVF IS-PU-UL or IP IP IP IS-PU-S Local system PC master station 2 PS-2420/D/UL/S* (IS-SOFT) 2 IS-RCU (Max. 1) PS-2420/D/UL/S* or PA speaker PA amplifi er or PoE IS-PU-UL PoE or IS-PU-S AC IS-SS (Max. 30) PT transformer IS-RS Recorder and /or EL-12S Electric door strike 8 Ω speaker Call button Strobe light 2 * : Do not use PS-242
ページ8に含まれる内容の要旨
Cables Cables and connectors are not included with the products. Refer to page 9 to 26 for details about each unit connection. Notes on cables • Unless otherwise noted, never use individual Odd number cables, such as • conductors, twisted pair cable or coaxial cable. three conductor wire, cannot be used. Notes on CAT5e/6 cables Arrange the color code of the RJ45 connections in accordance Do not bend the cables to an extent where the radius is • • with EIA/TIA-568A or 568B. less than 25
ページ9に含まれる内容の要旨
UNIT DETAILS Control unit common information * The information on this page is common to Central control unit (IS-CCU), Add-on control unit (IS-SCU), Room sub control unit (IS- RCU) and IP control unit (IS-IPC). ■ Accessories *1 Mounting bracket × 2 Installation manual (a booklet) × 1 *2 Screw (for wall-mounting) × 4 CD-ROM (Installation manual, Setting manual and Operation manual) × 1 Screw (for rack-mounting) × 4 China RoHS paper × 1 Screw (for fi xing mounting bracket) × 6 *1: IS-CCU
ページ10に含まれる内容の要旨
( ) Central control unit IS-CCU ■ Part names CONTACT INPUT terminals CHIME INPUT terminals CONTACT OUTPUT terminals External chime source volume 1 and 2 Adjust the volume of the input source (for chime) connected to the PA (Paging) OUTPUT terminals CHIME INPUT B1 and B2 terminals respectively. POWER switch Turns the power ON ( ) or OFF ( ). POWER LED (green) Lights up when the power is ON. Room sub control unit POWER terminals (IS-RCU) ports STATUS LED (green) 1 * Blinks when this unit is in
ページ11に含まれる内容の要旨
Connections ■ Chime input (50mVrms, 600 Ω) PA output Contact output *8 PC for setting External sound (50mVrms, 600 Ω) (Electric door strike, strobe light, etc.) the system Contact input *9 *7 *7 source such as Monitor 1, Monitor 2, PA amplifi er Sensor, etc. CD player, etc. *6 Recorder 1 Recorder 2 *2 *3 BNC BNC *1 *4 NP connector P NP connector 2C 2C 2C NP NP NP φ0.65-1.2mm φ0.65-1.2mm φ0.65-1.2mm (22-16 AWG) (22-16 AWG) 2C 2C 2C (22-16 AWG) φ0.65-1.2mm φ0.65-1.2mm φ0.65-1.2mm 15m (50') 15
ページ12に含まれる内容の要旨
( ) Add-on control unit IS-SCU Part names ■ CONTACT OUTPUT terminals PA (Paging) OUTPUT terminals POWER switch Turns the power ON ( ) or OFF ( ). POWER LED (green) Lights up when the power is ON. POWER terminals MASTER STATION ports STATUS LED (green) 1 * Blinks when this unit is initialized or an error ID setting switch occurs. VIDEO/AUDIO DOOR/SUB STATION ports (→P.13) The LED will light up when this unit returns to the normal state. Central control unit (IS-CCU) ports 1 * : Communicati
ページ13に含まれる内容の要旨
Connections ■ Contact output *4 (Electric door strike, strobe light, etc.) PA output (50mVrms, 600 Ω) Monitor 1, Monitor 2, PA amplifi er Recorder 1 Recorder 2 BNC BNC *1 connector connector NP NP NP 2C 2C 2C φ0.65-1.2mm φ0.65-1.2mm φ0.65-1.2mm (22-16 AWG) (22-16 AWG) (22-16 AWG) AC Coax Coax transformer PT 15m (50') 15m (50') 15m (50') NTSC NTSC BNC BNC NP: Non-polarized connector connector P: Polarized P1 P2 P3 P4 L1 L2 L3 L4 V1 V2 PA OUTPUT (600 Ω) CONTACT OUTPUT (AC/DC24V 0.5A) VIDEO OUT
ページ14に含まれる内容の要旨
( ) Room sub control unit IS-RCU Part names ■ CONTACT OUTPUT terminals PA (Paging) OUTPUT terminals POWER switch Turns the power ON ( ) or OFF ( ). POWER LED (green) Lights up when the power is ON. POWER terminals AUDIO DOOR/SUB STATION ports STATUS LED (green) Central control unit (IS-CCU) / *1 Blinks when this unit is initialized or an error ID setting switch IP control unit (IS-IPC) ports occurs. (→P.15) The LED will light up when this unit returns to the normal state. *1 : Communicati
ページ15に含まれる内容の要旨
Connections ■ Contact output *4 (Electric door strike, strobe light, etc.) PA output (50mVrms, 600 Ω) PA amplifi er *1 NP NP NP 2C 2C 2C AC φ0.65-1.2mm φ0.65-1.2mm φ0.65-1.2mm PT transformer NP: Non-polarized (22-16 AWG) (22-16 AWG) (22-16 AWG) P: Polarized 15m (50') ID setting switch *3 P1 P2 P3 P4 L1 L2 L3 L4 PA OUTPUT (600 Ω) CONTACT OUTPUT (AC/DC24V 0.5A) IS-CCU/ IS-IPC AUDIO DOOR/SUB STATION 1 C1 C3 C5 C7 C9 C11 C13 C15 C17 C19 C21 C23 C25 C27 C29 CX1/IP1 2 DC48V 3 ID C2 C4 C6 C8 C10 C12
ページ16に含まれる内容の要旨
( ) IP control unit IS-IPC IP This unit is needed to connect a local system to a standard (IP) system. ■ Part names CO port (Telephone) LAN port POWER switch Turns the power ON ( ) or OFF ( ). POWER LED (green) Lights up when the power is ON. POWER terminals Central control unit (IS-CCU) / STATUS LED (green) Room sub control unit (IS-RCU) ports 1 * Blinks when this unit is initialized or an error occurs. The LED will light up when this unit returns to the normal state. *1 : Communication e
ページ17に含まれる内容の要旨
Connections ■ PBX/Telephone Switch (Hub) (North America only) 10BASE-T 100BASE-TX 100m (330') LAN CO ETHERNET TELEPHONE IS-CCU IS-RCU DC48V IP1 IP2 IP3 IS-CCU IS-RCU P: Polarized P IP1 IP2 IP3 2C φ0.8-1.2mm (20-16 AWG) CAT5e/6 (x3) (non-shielded) 15m (50') CAT5e/6 (x2) 10m (33') (non-shielded) 10m (33') or CX1/IP1 CX2/IP2 IP1 IP2 IP3 *3 Central control unit Power supply unit Room sub control unit (IS-CCU) *1 (IS-PU-UL/IS-PU-S) (IS-RCU) *2 *1: When connecting a central control unit (IS-CCU) t
ページ18に含まれる内容の要旨
Color monitor master station (IS-MV) * For the part names and their functions, see the OPERATION MANUAL. ■ Accessories Mounting bracket × 1 Name card × 1 Desktop stand × 1 Screw (15mm (5/8"), for wall-mounting) × 4 Tie-wrap × 1 Screw (25mm (1"), for gang box) × 4 Name plate × 1 Screw (10mm (7/16"), for desktop stand) × 4 China RoHS paper × 1 ■ Mounting When mounting on a wall Mount the unit on the 3-gang box NOTE: 3 1 Name card × 1 (included* ) mounting bracket. A singl
ページ19に含まれる内容の要旨
When mounting on a desktop stand Set up the desktop 1 Mount the unit on the 4 stand. mounting bracket. * Set up the desktop stand on Fasten the mounting 2 a level surface etc. so that it bracket to the desktop is stabilized. Fix the desktop stand in place if needed. stand. * The desktop stand allows you to adjust it in 3 setup angles. Put the leg in a groove on the base that corresponds to the CAT5e/6 cable desired angle. 30 Leg Base The unit Option wires 45 Screw (for desktop stan
ページ20に含まれる内容の要旨
Vandal-resistant video door station (IS-DV, IS-DVF), Vandal-resistant audio door station (IS-SS) Accessories ■ Screw (for wall-mounting) × 4 (IS-DV only) Special screwdriver × 1 Anchor × 4 (IS-DV only) Back box × 1 (IS-DVF and IS-SS only) Transparent name plate × 2 (IS-DV and IS-DVF only) China RoHS paper × 1 Special screw × 4 (IS-DVF and IS-SS only) Mounting locations (IS-DV and IS-DVF) ■ Do not install this unit in any of the following locations where lighting or the ambient environm