ページ1に含まれる内容の要旨
0207 C AI
GH SERIES
Apartment Intercom System
INSTALLATION &OPERATION MANUAL
- 1 -
ページ2に含まれる内容の要旨
PRECAUTIONS General Prohibitions Prohibition to Dismantle the Unit Prohibition on Subjecting the Unit to Water General Precautions WARNING (Negligence could result in death or serious injury to people) 1. The unit must be installed and wired by a qualified technician. 2. Do not dismantle or alter the unit. Fire or electric shock could result. 3. Do not connect any non-specified power source to the +, - terminals, and do not install two power supplies in parallel to a single input. Fire, damage
ページ3に含まれる内容の要旨
W P D A M J G T X Q 1 2 3 B E H4 K5 N6 7 U8 9 0 SYSTEM CONFIGURATION 1 1-1 a () b c d e c d Max. 48 Max. 48 Max. 25 / Trunk Max. 25 / Trunk [10] [10] Trunk GH-1KD GH-1KD (1) :A #6 ~ #2 (2) :V [9] GH-4Z (3) :P GH-1KD Max. 6 [10] [10] [10] GH-1KD GH-1KD a b GH-VBC GH-VA + GH-DA/A + [6] GH-NS, GH-10K GH-1KD GH-VA [10] [1] 2 [10] [10] GH-1KD GH-1KD [5] PS24 [9] GH-4Z GH-1KD Max. 6 [10] GH-BC [5] [5] [7] [10] [10] PS24 PS24 GH-1KD GH-1KD Max. 5 Trunk (3 per trunk) [8] 2 #1 GH-DA/A 1 1 DP GH-VA + GH-
ページ4に含まれる内容の要旨
1-1 Standard System Configuration (1) Audio signal line (2) Video signal line (3) Power supply line a. Entrance station (For details, see 2-1 and 2-2) [1] Audio/video + digital name scrolling type GH-VA + GH-DA/A + GH-NS, GH-10K [2] Audio/video + direct selection type GH-VA + GH-DA/A + GH-SW [3] Audio + digital name scrolling type GH-DA/A + GH-NS, GH-10K [4] Audio + direct selection type GH-DA/A + GH-SW b. Bus control units [5] Power supply PS-2410LC, PS-2410LD, PS-2410DIN [6] Video Bus control
ページ5に含まれる内容の要旨
1 SYSTEM CONFIGURATION Standard System Configuration 4 Expanded System Configuration 6 Wiring Distance 7 2 COMPONENTS Unit (Entrance Station) 8 Combination Examples for Entrance Station, Unit (Bus Control Unit and Others) 9 Residential Station, Security Guard Station 10 3 MOUNTING Mounting the Entrance Station (1) 11 Mounting the Entrance Station (2), (3) 12 Bus Control Unit and Power Supply 13 Residential Station, Optional Handset 14 Security Guard Station (Desk-top Mounting Using the GFW-S Sta
ページ6に含まれる内容の要旨
W P W P D A M J G T D A M J G T X Q X Q 1 2 3 B E 4 5 6 H K N 7 U8 9 0 1 2 3 B E 4 5 6 H K N 7 U8 9 0 1-2 1 2 #1 #1 () b c d a e #2 () b c d f #2 #3 () b c d a #4 () e b c d #1 #1 b a f [1] GH-VBX #2 GH-VBC GH-VA + GH-DA/A + GH-NS, GH-10K #3 [4] [4] #4 PS24 GH-VA PS24 GH-DA/A Max. 8 GH-BC (3 per trunk) [4] GH-BC PS24 [4] PS24 e Max. 125 GH-MK [3] DP Max. 25 / Trunk [3] DP () c d PS24 GH-1KD / GH-4Z Max. 2 [4] [2] GH-BCX/A [4] #2 #2 PS24 a GH-VA + GH-DA/A + GH-NS, GH-10K [4] #2 PS24 GH-VA #3 GH
ページ7に含まれる内容の要旨
1-2 1-3 Expanded System Configuration Diagram Wiring Distance 1. Common trunk line #1, 2 ∗ DP = Distribution Point 2. Sub trunk line #1 - 4 0.65 mm 0.8 mm 1.0 mm Diameter of wires Sub trunk line #2 - #4 are the same as #1. Maximum 125 units (22 AWG) (20 AWG) (18 AWG) per sub trunk line. GH-BC - DP - 5 m - (1) Audio signal line (16') (2) Video signal line DP - GH-DA/A - 300 m - (3) Power supply line (980') a. Entrance station (For details, see 2-1 and 2-2) GH-VBC - GH-VA 150 m 300 m - (490') (98
ページ8に含まれる内容の要旨
Unit (Entrance Station) COMPONENTS 2 [1] Speech module panel GH-DP [2] Speech module GH-DA/A 2-1 [3] Camera module panel GF-VP [1] [2] [3] [4] [4] Camera module GH-VA [5] 1-call button panel GF-1P [6] 2-call button panel GF-2P [7] 3-call button panel GF-3P [8] 4-call button panel GF-4P [9] Call switch module GH-SW [5] [6] [7] [8] [9] [10] Digital name scroll module panel GF-NSP [11] Digital name scroll module GH-NS [12] RS-232C cable (included with GH-NS) [13] Digital keypad module panel GF-10KP
ページ9に含まれる内容の要旨
2-3 2-2 [1] [2] [3] 12 AIPHONE AIPHONE [4] [5] 34 AIPHONE AIPHONE [6] [7] Combination Examples for Entrance Station 1. Audio only. Direct selection (8 stations). [8] [9] 2. Audio/video. Direct selection (8 stations). 3. Audio only. Digital name scrolling. 4. Audio/video. Digital name scrolling. [10] [11] [12] Unit (Bus Control Unit and Others) [1] Bus control unit GH-BC (mounting bracket is not included) [2] Special screwdriver (included with GH-BC) [3] CD (contains operation manual and setup to
ページ10に含まれる内容の要旨
W P D A M J G T X Q 1 2 3 B E 4 H 5 K 6 N 7 8 9 U 0 2-4 2-5 [1] [2] [3] [1] [2] [3] [4] [5] [6] Security Guard Station [1] Security guard station GH-MK [2] Mounting screws (enclosed with GH-MK) [3] RS-232C cable (enclosed with GH-MK) Residential Station [1] Audio residential station GH-1AD [2] Color monitor residential station GH-1KD [3] Mounting screws (enclosed with GH-1AD and GH-1KD) [4] Black-and-white monitor residential station GH-1MD [5] Mounting screws (enclosed with GH-1MD) [6] Optional
ページ11に含まれる内容の要旨
Mounting the Entrance Station (1) MOUNTING 3 [1] Back box [2] Joint pipe 3-1 [3] Back box assembly dimensions [1] 1 [4] Special screwdriver (enclosed with GH-BC) [2] 1. Mounting the back box • Make a hole for the cable. 200mm [1] (7-7/8") • Use the joint pipe to assemble the back box. • Make sure the back box is mounted level. 25mm • Mount the camera and GH-NS module at eye-level for the (1") [2] 44mm average height of an adult. W (1-3/4") 15mm Do not mount the back box on a surface that is rec
ページ12に含まれる内容の要旨
1 1 1 1 3-2 3-3 1 GH-DA/A GH-NS 1 GH-DA/A CN1 CN3 CN2 GH-VA CN3 CN1 GH-DA/A CN1 CN100 CN2 GH-AD GH-10K 23 GF-C 2 GH-VA GH-NS GH-DA/A GH-DA/A GH-10K GH-DA/A CN2 GF-3B GF-3B GF-3B GH-AD GF-BP GH-SW GF-C CN1 GF-3B GF-3B 3 Mounting the Entrance Station (3) 1. Example of interconnection of modules. CN2 CN1 2. Use GF-C to connect to the name scrolling module. 3. To position the speech module in the center row, run GF-C through the joint pipe in advance. CN1 CN2 CN2 CN1 CN1 CN2 CN2 CN1 4 5 GH-DA/A Mo
ページ13に含まれる内容の要旨
Bus Control Unit and Power Supply 3-4 [1] Din rail (W-DIN11) [2] Screw hole 12 [3] POWER switch [4] Power On LED (green) [5] Lock release lever [1] [6] Wall mounting screws (x2) [2] 1. Mount GH-BC and GH-VBC to the Din rail. Click unit into [1] place. GH-BC ∗ To remove GH-BC and GH-VBC, pull the lock release lever GH-VBC [3] down. [6] ∗ If there is a problem with the system, check the power supply [2] [4] GH-BC GH-VBC wiring. Turn off the GH-BC and GH-VBC power switch and ON OFF then turn th
ページ14に含まれる内容の要旨
3-5 3-6 [3] GH-1AD [2] GH-1KD [1] [1] [2] [3] 1 83.5mm (3-5/16") OR 60mm (2-3/8") [3] SW1 A B Do not remove the wires (For end users) IN OUT 0.65 10 9 2 R1 R2 R1 R2 C CE K KE [4] Optional Handset [1] Chassis [2] Handset (GH-HS) [3] Screws (x2) • Connect the station unit joint connector. 3 GH-HS can be installed only for the color monitor residential station (GH-1KD). GH-1MD Residential Station [1] Mounting screws (x2) [2] Mounting bracket [3] 1-gang box or round back box [4] Terminal blo
ページ15に含まれる内容の要旨
W P W P D A M J G T D A M J G T X Q X Q 1 2 3 B E 4 5 6 H K N 7 8 9 U 0 1 2 3 B E 4 5 6 H K N 7 8 9 U 0 R Y 3-7 3-8 [2] [1] [1] 12 83.5mm (3-5/16") OR 60mm (2-3/8") [2] 3 [1] [3] 45 [4] Security Guard Station (Wall-mounting) [1] 1-gang box or round back box [2] Mounting bracket [3] Wiring slot [4] Terminal block Security Guard Station (Desk-top Mounting Using GFW-S Stand) 1. Mount the mounting bracket on the 1-gang box. [1] Screws included with GFW-S (x4) 2. Connect the wiring to the terminal bl
ページ16に含まれる内容の要旨
W P D A M J G T X Q 1 2 3 B E 4 5 6 H K N 7 8 9 U 0 WIRING 4 Standard system Capacity 1P(Audio) 1P(Video) 5 Entrance stations 1P 2 Security guard stations 48 Residential stations Homerun wiring with GH-4Z Station-to-station wiring Trunk line #2 Trunk line #1 1Px2 1Px2 1Px2 1Px2 Doorbell GH-1KD GH-4Z 1Px2 1Px2 1Px2 1Px2 1Px2 1P 1P 1Px2 GH-4Z Doorbell Doorbell Doorbell Doorbell GH-1KD GH-1KD GH-1MD GH-1KD GH-1AD GH-1AD GH-1KD GH-1MD, unlike GH-1KD, Max. 4 apartment stations can be linked per R
ページ17に含まれる内容の要旨
Homerun wiring with GH-4Z Station-to-station wiring Trunk line #1 Trunk line #2 GH-4Z Terminate A B the last GH-4Z B1 OUT R1 R2 B1 B2 B2 GH-1KD B1 IN B1 B1 B2 OUT OUT 1Px2 B2 R1 R2 B1 B2 B2 1Px2 1Px2 R1 LINE OUT B1 B1 B1 B1 OUT IN IN R2 B2 B2 B2 B2 OUT 3 OUT 4 R1 R1 R1 R1 R1 IN R1 OUT OUT R1 R2 OUT R2 R2 R2 R2 OUT R2 R2 C R1 R1 IN IN R1 R1 CE R2 R2 IN IN R2 R2 C C A B Door C C GH-4Z CE CE bell GH-1KD CE CE A B 1Px2 GH-1AD GH-1AD A B A B Doorbell B1 B1 OUT OUT 1Px2 1Px2 GH-1KD B2 B2 B1 B1 B1 B1
ページ18に含まれる内容の要旨
W P A M J G T D X Q 1 2 3 B E 4 5 6 H K N 7 U8 9 0 4-1 PS-2410LC PS-2410LD PS-2410DIN [9] a AC AC PS24 () b c d AC e 1P NP GH-VA #2 - #5 PS24 AC 1P GH-NS NP #2 , #3 A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 GH-NS #1 GH-VA #1 a b SW2 EXP STD [1] A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 IN1 IN2 IN3 IN4 IN5 GH-VBC [10] GH-VBC OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 + – B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 9mm + – A1A2 + – A1 A2 CN3 CN3 CN1 + PS24 – B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 AC 1P GH-10K #1 GH-DA/A #1 NP [4] GH-RY () c
ページ19に含まれる内容の要旨
4-1 4-2 Standard System (1) [1] Entrance Station a [2] Door release timer (set to "M" at time of shipment) b c • Set the duration for the door release function when the door e release button is pressed. [0.5] - [20]: 0.5 secs - 20 secs 1P [20] - [M]: Activates while the button is pressed. NP GH-1AD [3] Setting switch (GH-DA/A) IN OUT • SW2: 1: Setting switch for camera entrance station monitoring R1R2 R1R2 C CE K KE function (set to OFF at time of shipment) ON (Up): Monitored. OFF (Down): Skip
ページ20に含まれる内容の要旨
4-3 GH-1MD a 1P B1 B2 R1 R2 C CE K KE B1, B2 NP b d Do not remove the wires! GH-4Z e 1P R1, R2 NP GH-1AD d IN OUT A R1R2 R1R2 C CE K KE B SW1 R1, R2 B1B2 R1R2 B1B2 R1R2 B1B2 R1R2 GH-4Z 1P NP SW1 A B GH-4Z GH-1KD [2] IN OUT IN OUT B1B2 B1B2 R1R2R1R2 C CE K KE B1B2 R1R2 B1B2 R1R2 B1B2 R1R2 1P 1P NP NP [3] K KE 1P [2] NP A 1P B NP SW1 SW1 B A GH-1KD B1B2 R1R2 B1B2 R1R2 B1B2 R1R2 [2] IN OUT IN OUT B1B2 B1B2 R1R2R1R2 C CE K KE GH-4Z 1P NP [3] B1B2 R1R2 B1B2 R1R2 B1B2 R1R2 1P NP SW1 B A 1P GH-1K